Midwestern Engineers, Inc. Plan Preview
, 0 - " " ' " z � ' , ' i z :;eU-' ! ��i ' N 98 Q , st ,"', Q 1"11 � g � '- ON -o -:?'j·� :t:...J ;,W :t •• 15 � - i.l. D...1 ct � - Cl.. ... .s>::. ci a. 0 al rU " oz g;; ' ,. u9 5N e C ·- , . <c GENERAL MECHANICAL NOTES MECHANICAL CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FOR REQUIREMENTS RELATING TO EQUIPMENT QUAUTY, CONSTRUCTION AND FINISH OF MATERIALS. THESE DRAWINGS INDICATE REQUIRED SIZES AND POINTS OF TERMINATION FOR PIPING, DUCTWORK, CONDUIT, ETC. THE EQUIPMENT SHOWN ILLUSTRATES SUGGESTED ROUTING, BUT ALL NECESSARY OFFSETS AND FITTINGS MAY NOT BE SHOWN. CONTRACTOR SHALL INSTALL HIS WORK IN A MANNER THAT WILL CONFORM w/ THE STRUCTURE. CONTRACTOR SHALL AVOID OBSTRUCTIONS, PRESERVE HEADROOM AND MAINT AIN MAXIMUM CLEARANCE WITHOUT FURTHER INSTRUCTION FROM THE ENGINEER OR ADDmONAL COST TO THE OWNER. ALL DIMENSIONS SHOWN ON THESE PLANS ARE IN FEET AND/OR INCHES UNLESS NOTED OTHERWISE. ALL DUCTWORK, PIPING AND VALVES SHALL BE CONCEALED ABOVE CEILINGS ANO WrTHIN WALJ.S IN FlNISHED AREAS UNLESS OTHERWISE NOltD, ALL SUPPLY, RETURN ANO OUTSIDE AIR OUC1WORK SHAU. SE INSULATED w/ 1)1" DUCTWRAP. EQUIPMENT SIZES AND SE!ivlCE SPACE REQUIRcMIMs MAY v� iit'iVIEEN DIITTRENi MANUFACTURERS, CONSULT APPROVED MANUFACTURER DRAWINGS ;/;; stJ!iMlmil, AND CODROINAIT w/ THEsE DRAWINCS, All EiitJiPMENT sHAlb liE llF, AND CONSIST QF AT lEAST !Hi': MINIMUM SIZ!s scHEiitJLEO, ALL EXISTING i':QtJIPMENf 1 DtJClWORK ANO PIPING L(JeA'MNS AND SIZES SHAll lie FIELD \ltRIFl,D PRIOR i1'l coNSTRtJcTioN BY THE cONTAAcmlt ALL VALVES, coils, DAMPERS, Efc, SHALL BE IN!rrAlliO AilDWING EASY ACCESS, AREAS ADJACENT j() Tfli': ACC.SS PANELS SHALL BE CLEAR OF /.N'( OBSTRIJCiiONS. ALL WALL THERMOSTATS SHAlb BE APPRox1MA1'El1' 4'-6" ABiiVE FlNISH FLOiiR i1'l BOTTOM AND LJNED UP HORIZQNTALlV w/ LIGHT SWITCHES UNLESS OTHERWISE NOTED OF DIREClED 81' fHE ENGINEER. THERMOSTATS IN PUBLIC AREAS SHALL HAVE LOCK!NG COVERS. COMBUSTION AJR PIPE SHALL BE PVC. G/oS VENT PIPING SHALL BE CPVC UNLESS OTHERWISE NOTED. CONTROLS AND SEQUENCE OF OPERATION SHALL BE ,s INDICATED ON DRAWINGS. PROVIDE A MINIMUM OF 10' -o• FROM 00 EQUIPMENT AND PLUMBING VENTS FROM ALL OUTSIDE A!R INTAKES, DOORS, OR OPERABLE WINDOWS. REFER TO MECHANICAL SCHEDULES AND DITA!LS FOR ADDITIONAL EQUIPMENT REQUIREMENTS. EACH RESPECTIVE CONTRACTOR SHAU BE RESPONSIBLE FOR COORDINATING THE INSTALLATION OF HIS WORK w/ THE WORK OF OTHER CONTRACTORS PRIOR TO THE INSTALLATION. REFER TO ELECTRICAL AND PLUMBING DRAWINGS FOR ADDmONAL COORDINATION w/ THESE DRAWINGS. CONTRACTOR SHALL NOT LOCATE AfN DUCT OR PIPING DIRECTLY OVER ANY ELECTRICAL PANELS, SWITCH GEAR, TRANSFORMER, ETC. COORDINATE LOCATIONS OF DUCTS AND PIPING w/ THE ELECTRICAL CONTRACTOR TO AVOID THESE CONFUC"TS. ALL HVAC SYSTEMS SHALL BE WIRED BY THE ELECTRICAL CONTRACTOR AND SHALL BE PLACED ON A DEDICAlED CIRCUIT. SERVICE SPACE FOR EQUIPMENT SHALL NOT BE BLOCKED w/ PIPING, DUCTWORK, ETC. DUCTS PENETRATING ROOF, FLOOR SlABS AND/OR WALLS SHALL BE SEALED AS REQUIRED BY CODE. DUCTS PENETRATING FIRE RATED WALL AND/OR FLOOR SHALL HAVE OPENING AROUND DUCT SEALED w/ A MATERIAL HAVING THE SAME FIRE RATING AS THE WALL OR FLOOR. ITEM AREA MANUFACTURER AH-1 FlLTER BUILDING TRANE OR ENGINEER APPROVED EQUAL CU-1 FlLTER BUILDING TRANE OR ENGINEER APPROVED EQUAL GENERAL COOLING MODEL CAPACITY (95"F, MBH) TPKAOA0241KA70A 24,0/10.0 1'RUZA0241HA70NA HEATING CAPACITY (47 ° F, MBH) 28.0/9.0 DIMENSIONS EER L w H 46.1" 11.6" 14.4" 12.2 37.4• 13" 37.1" GENfiRAI:. - ' ltEM - - MAU-1 MAU-2 -- LdtATi6N - - HEADWORKS FILTER BUILDING - MFR MODEL TYPE GREtNHECK iJR ENGINEER APPROVED EQUAL CONSTANT VOLUME 100% OUJSIDE AJR DGX-P122-H22-MF GREENHECK OR ENGINEER APPROVED EQUAL CONSTANT VOLUME 100% OlJTSIDE AIR DGX-P116-H22-MF / ROOF MOUNTED DOWNBLAST �:::::S�i:i----, EXHAUST FAN 111lll �� =-. a!v I/ BIRDSCREEN AIRF C_)- � i-- + ' ------1.---, �-- INSULATED ROOF CURB / ;I ELASTOMERIC FLASHING BACKDRAFT DAMPER ======�/� ' .. 0 . -,. -·· - ' CONDUIT AND WIRING (REFER j TO ELECTRICAL DRAWINGS) EXHAUST DUCT (SIZE PER PLAN)� j I \ ROOFING SYSTEM (REFER L S,S, EXHAUST TO STRUCTURAL DRAWINGS) GRILLE FRP CEILING PANEL NOTE: SEE FLOOR PLAN FOR MOUNTING HEIGHT DIRECTION OF AIR FLOW MOTORIZED� EXHAUST OAMPER INTERLOCK TO FAN GREENHECK W0-330 ;-EXTERIOR WALL CONSTRUCTION /; 1 WALL SLEEVE BY FAN MANUFACTURER / 1 - - --- BIRDSCREEN OVER £At! -------- AIR OUTLET I I I II " I '-------' \ STAINLESS STEEL ANCHOR BOLTS (TYP) DIRECT DRIVE w/ 2 SPEED FAN CONTROLLER, GREENHECK VARI-GREEN ROOF MOUNTED EXHAUST FAN SIDEWALL MOUNTED EXHAUST FAN NOT TO SCALE NOT TO SCALE MINI-SPLIT HEAT PUMP SCHEDULE INDOOR UNIT OUTDOOR UNIT CFM CFM NOISE WEIGHT (DB) (WB) (OBA) EAT EAT (DB) (WB) CONTROLLER CFM NOISE (OBA) REFRIGERANT SUPPORT 46 635/705/775 570/635/700 39/42/45 90.0 TAR-40MMU (DELUXE WIRED REMOTE) ?2.0 PAC-UKPRC001-CN-1 (BACNET INTERFACE) 153 - - - 1940 MAKEUP AIR UNIT SCHEDULE SUPPl:Y FAN DATA biMENSIONS L I 1sa· 158" ITEM EF-1 EF-2 EF�3 Ef-4 ITEM UH-1 UH-2 I WEIGHT GFM QA ESP RPM BHP ·w H 44" 45" 1190 6121 6121 1.0 1308 3.42 44• 45• 1133 LOCATION HEADWORKS FlLTER BUILDING SLUDGE DEWATERING CHEMICAL FEED LOCATION HEADWORKS SLUDGE DEWATERING CHEMICAL FEED 4705 4705 LO GENERAL MANUFACTURER GREENHECK OR ENGINEER APPROVED EQUAL GREENHECK OR ENGINEER APPROVED EQUAL GREENHECK OR ENGINEER APPROVED EQUAL GREENHECK OR ENGINEER APPROVED EQUAL 1934 2.48 MODEL G-240-VG-GPI G-240-VG-GPI CUE-095-D CUE-100-A GENERAL MANUFACTURER MODEL QMARK OR ENGINEER MUH03-81 APPROVED EQUAL QMARK OR ENGINEER MUH03-41 APPROVED EQUAL dAS-FIRED Hl:Af CAPACITY (MBH) AIR TEMP ( ° F) INPUT OUfPUT ENT LVG 503.0 462.8 0.0 70.0 386.6 355.7 0.0 70.D PRESSURE (IN W.C.) MIN MAX 9.0 14.0 9,0 14.0 EXHAUST FAN SCHEDULE FAN DATA WEIGHT CFM TIP SPEED S.P. RPM (FPM) (IN) 207 5565 4915 0.605 766 207 4277 4242 0.57 661 49 300 3781 0.481 1328 72 900 4148 0.544 1424 TYPE DIRECT DIRECT BHP 1.19 0,75 0.06 0.16 ELECTRIC UNIT HEATER SCHEDULE FAN DATA DIMENSIONS TEMP RISE THROW WEIGHT CFM ( ° F) (FT) L w H 14" 7.5· 16" 27 350 27 12 14" 1.s· 16" 27 350 27 12 R410A QSWBSS S.S. WALL BRACKol FILTERS QTY SIZE TYPE 6 2o·x2o·x2· MERV 8 6 SONES DRIVE VOLTS 14.6 DIRECT 208 10,8 DIRECT 208 6,6 DIRECT 120 8,2 DIRECT 120 RESISTANCE HEAT MOTOR SIZE OUTPUT {HP) (KW) (MBH) 1/100 3.0 10.2 1/100 3.0 10.2 ELECTRICAL VOLTS PHASE 208 ELECTRICAL VOLTS PHASE 208 3 208 3 ELECTRICAL PHASE 3 3 VOLTS 20B 480 MOTOR (HP) 2 2 1/8 1/3 ELECTRICAL PHASE 1 3 MCA MOCP 19,0 30 MCA MOCP 22.8 35 13.9 20 MCA MOCP 16 30 16 30 9 20 MCA MOCP 14.5 20 3,6 15 I ... 9 � REVISIONS 3/15/24 BID SET C2024 Midwestern Enginc>ers. Inc. 802 Wrsl Brn:,dway Scree! P.O. Box 195 Loogoo!�c. lndiann 47553 OATE MARCH 2024 DESIGN A.F.8. DRAWN C.N.M. Q.C. CHECK W.A.E. PROJECT NUMBER 2020073-00 Hl.01 102 OF 126 FlLE NUMBER 43964 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2