Midwestern Engineers, Inc. Plan Preview

£ Q w w " z • , � � I 0 I N � " c � it > 9 � Q Q 0 Q 0 oc • � N � � , w � Q 0 I -1 <> 8 • ! oc � -:-l� I=' : o'.il� 1 Q ····, ..''' g vf � �� ' - < N �::;-i� I u •• <I> cc � ro .,( "'o_, < 0 c.. - Q-, ,i "o J: >0 az o- QO ,� uY ,� <c ;:;;;; SC o ' ' ' ' ' BRONZE PLUG - -CLEANOUT BOX w/ DUCTILE IRON COVER 2" COMPACTED - SAND BED 18"x18"x6"D I CONCRETE PAD I GRADE Ii· -":· i II II"• '• •• i �� ,rfr ; ;; 111 · ; 11 _ � -----m - - , === , I 11 11 I E I 1 1 i' 11111 1 11 Ill ;> ' iii i BACKFILL � ---/- -w- ,I === vs� �its TO SEWER WYE AND Jii BEND w/ CLEANOUT / WYE AND Jii BEND IF EXTENSION TO GRADE PLACED IN SEWER LINE. (SWING JOINT) JI BEND I F PLACED AT END OF SEWER LINE. '--nr--� J'l"-----ftr-- r I Ill \ > ' Ill ', ( � FLOW f Ill ,.... �-----1..l>-------�__,,.___� EXTERIOR CLEANOUT DETAIL 'A' NOT TO SCALE GAS REGULATOR (GR-1) 1)," (12" W.C.) .J:.'.'.'._... ........, f GAS TO MAKE-UP SHUTOFF VALVE- --l<', rl[� CONNECT 1!," 1J AIR UNIT NION 1 Y. 'i -DIRT-LEG � RADE f l �TRANSITION FROM POLYETHYLENE TUBING TO SCH. 40 STEEL PIPE ABOVE GRADE �1)1" METERED GAS SERVICE ,l (2 PSI) FROM LAB BUILDING GAS REGULATOR DETAIL 'B' NOT TO SCALE PLUMBING SYMBOLS AND ABBREVIATIONS - . - - - ABBREVIATIONS PLUMBING SYMBOLOGY DRAWING SYMBOLOGY AFF ABOVE FINISHED FLOOR 1MB ICE MAKER BOX ---M-- SHUTOFF VALlft_ r ELBOW COLO WATER MS ABOVE GRADE INV INVERT ELEVATION AP ACCESS PANEL LAVATORY :r - ANGLE VALVE 1+1 TEE HOT WATER L AD AREA DRAIN LT LAUNDRY TUB -,o;--BAlANCING VALVE � PIPE TURNING DOWN ALT ALTERNATE MBH lHOUSANDS OF BTU PER HOUR HOT WATER RETURN BAS BUILDING AUTOMATION SYSTEM MC MECHANICAL CONTRACTOR f - BAU. V/J..VE PIPE TURNING UP - COLD SOFT WATER BF BELOW FLOOR MH MANHOL£ BG BELOW GRADE MS MOP SINK I� BUTTERFLY VALlft_ --<p- TEE UP 14 140" HOT WATER BFP BACKFLOW PREVENTER NPW NON-POTABL£ WATER BOP BOTTOM OF PIPE NTS NOT TO SCALE ---N-- CHECK VALVE T TEE DOWN 140 140' HOT WATER RETURN BTU BRmSH THERMAL UNIT ORD OVERFLOW ROOF DRAIN � CONTROL VALVE -a>-- DROP AND RUN COMPRESSED AIR BTUH BTU PER HOUR OSD OPEN SITE DRAIN ' CB CATCH BASIN PRV PRESSURE REDUCING VALVE PLUG VALVE -<>-- REDUCER - NATURAL GAS Cl CAST IRON RD ROOF DRAIN --0- - ,jf -- co Cl£ANOUT RPZ REDUCED PRESSURE BFP PRESSURE REDUCING VALVE UNION - ORA I N/REUEF COND CONDENSATE SAN SANITARY DRAIN ---&--- SOLENOID VAL\/F_ 1 9 S'TR/>JNER ---------------------- DEMOLITION CP CIRCULATION PUMP SE SEWMSE EJECTOR 'f- SAFETY RELIEF VALVE SUSPENDED CL.EANOUT csw COLD SOFT WATER SF SQUARE FOOT --------------------------- VENT r:v CONTROL Vl•J...lft_ SH SHOWER cw COLD WATER SK SINK -=- BACKFLOW PREVENTER PIPE CAP - SANITARY (ABOVE GRADE) DF DRINKING FOUNTAIN SP SUMP PUMP HOSE BIBB PIPE SL£EVE D� DIAMffiR ss SAFETY SHOWER SANITARY (BELOW GRADE) q DS DOWNSPOUT WAl..l. HYDRANT ,, PIPE ANCHOR ss STAINLESS STEEL - STORM (ABOVE GRADE) DN DOWN ST STORM DRAIN qi PRESSURE GAUGE --=- FLEXIBLE CONNECTION DW DISHWASHER TO TRENCH DRAIN STORM (BELOW GRADE) � - EC ELECTRICAL CONTRACTOR TMV THERMOSTATIC MIXING VALVE lHERMOMffiR FLOW ARROW ET EXPANSION TANK TOP TOP Of PIPE - ACID (ABOVE GRADE) EWC ELECTRIC WATER COOLER 1YP lYPICAL ---0--- PUMP = PIPE SLOPE DIRECTION EWH ELECTRIC WATER HEATER UR URINAL ACID (BELOW GRADE) --@--- AUTOMATIC AIR VENT @ FLOOR DR/>JN FD FLOOR DRAIN V VENT 0 jGMj PLAN NOTE FS FLOOR SINK VB VACUUM BREAKER GAS METER Eml FLOOR SINK GPM GAl..lONS PER MINUTE VCP VITRIFIED CLAY PIPE GC GENERAL CONTRACTOR vs VENT STACK @ WATER METER 0 CLEANOUT © DETAIL NUMBER GFWH GAS FlRED WATER HEATER VTR VENT l HRU ROOF GR GAS REGULATOR WB CLOlHES WASHER BOX DETAIL/SECTION HB HOSE BIBB WC WATER CLOSET DRAWING SHEET HR HOSE REEL wco WAU. CL.fANOUT HW HOT WATER WHA WATER HAMMER ARRESTER HWR HOT WATER RETURN ws WASTE STACK HYD WALL lf([)RANT N ZONE CONTROL VALVF. GAS REGULATOR (GR-2) 1 1)1" (12" W.C.) __ ........, f UPSIZE EXISTING GAS- METER AND SERVICE ii FOR 1,335,000 BTUH TOTAL CONNECTED ,._1)," 1 Y. " LOAD AT 2 PSI c;l I ",'',-l... ...;_ DELIVERY c'-'-�- ,. \ fV GAS TO MAKE-UP Hl t �CONNECT 1)1" 1),� - - - - SHUTOFF VALVE- --l( LW AIR UNIT UNION 1 ,i '--DIRT-LEG � RADE f l � �RANSITION FROM POLYETHYLENE TUBING TO SCH. 40 STEEL PIPE ABOVE GRADE �1" METERED GAS SERVICE ,l (2 PSI) FROM LAB BUILDING GAS REGULATOR DETAIL 'C' NOT TO SCALE SYSTEM MATERlAL SIZE FITTINGS JOINTS DOMESTICWATER ABOVE GRADE HARD COPPER TUBE HARD COPPER TUBE TYPE 'L' TYPE 'L' ASTM 888, NSF 61 ASTM 888, NSF 61 1/2" lHRU 4" 1/2" lHRU 4" WROUGHT COPPER COPPER/EPDM ASME 816.22 ASME 816.51 LEAD-FREE SOLDER PRESS-CONNECT ASTM 832 IAPMO PS-117 JOIN TUBE ANO INSTALLATION REQUIREMENTS COMPLY WITH CDA'S "COPPER TUBE HANDBOOK" FITTINGS WllH TOOLS RECOMMENDED BY HANGERS INSULATION TESTING CLEANING ITEM RPZ-1 RPZ-2 GR-1 GR-2 GR-3 FITTlNG MFR. COMPLY WllH MSS-SP-58 1/2' fHRU 3/4" 0 5' SPAGING, 3/8" ROD 1" THRU 1-1/4" 0 6' SPACING, 3/B" ROD 1-1/2" fHRU 2" 0 8' $PACING, 3/B" ROD 2-1/2" THRU 4" 0 10 1 SPACING, 1/2• ROD VERTCAL PIPE O 10' SPACING COMPLY WITH AS'fM [84 1" PREFORMED FIBERGLASS Wm-i A5J ASTM C552, iYPE: II, Cl.ASS :i TEST WITH WAlER Ai 50 PSI ABov( WORKING PRESSURE roR 24 HOURS FLUSH WITH POTABLE WATER. Fill SYSTEM WITH WATER/CHLORINE SOLUTION AT 50 PPM FOR 24 HOURS. FLUSH WITH POTABl£ WATER. SUBMIT WATER SAMPl£S TO IDOH. REPEAT UNTIL SATISFACTORY RESULTS ARE OBTAINED. DESCRIPTION BASIS OF DESIGN REDUCED PRESSURE WATTS BACKFLOW PREVENTER 919QT-1!f REDUCED PRESSURE WATTS BACKFLOW PREVENTER 919QT-1· GAS REGULATOR GLOBAL MffiRING 61R2-1Jf GAS REGULATOR GLOBAL MffiRING 61R2-1• GAS REGULATOR GLOBAL MCTERING 61R2-1 r FIXTURE BASIS OF DESIGN SS-1 FIXTURE: GUARDIAN G1950 F0-1 FIXTURE: J.R. SMITH 2310Y HB-1 FIXTURE: WOODFORD MODEL 26 EXISTING GAS -- -+ ' - --1------11� f SERVICE TO O ' LAB BUILDING r f - 1J , '' GAS REGULATOR (GR-3) � GRADE f f EXISTING NIPSCO f � GAS MAIN ' !: I f "-rnANSITION FROM POLYETHYLENE � TUBING TO SCH. 40 STEEL PIPE EXISTING GAS- - -t-- 1 - - - --- ABOVE GRADE SERVICE TO l; }--- MAINTENANCE )_,!; l 1)1" METERED GAS SERVICE BARN (2 PSI) TO MAKE UP AIR UNITS GAS REGULATOR DETAIL 'D' NOT TO SCALE PLUMBING MATERIAL SCHEDULE SANITARY WASTENENT ABOVE GRADE CAST IRON HUBL£SS ASTM A888 1-1/2" lHRU 6" CAST IRON DWV CISPI 301 HUBL£SS COUPLING C!SPI 310 COMPLY WITH C!SPI "CAST IRON SOIL PIPE & FITTINGS HANDBOOK" CHAPTER r, PVC SCHEDULE 40 ASTM D1784 1-1/2" lHRU 6" PVC DWv ASTM D2665 SOLVENT CEMENT ASTM D2564 COMPLY WllH ASTM D2665 AND 02855, NOT PERMITTED IN RETURN />JR PL£NUMS COMPLY WITH MSS-SfL58 1-1/2" lHRU 2" 0 5' SPACING, 3/8' ROD 3" 0 5' SPACING, 1/2" ROD 4- 0 5' SPACING, 5/8" ROtl 6 ° 0 S' SPACIN0 1 7/8" RoD VERTICAL PIPE O 10 1 SPACING NOT R£0UIR,D '!EST WllH WAITR Ai ID' HtAD tOR 2 HOURS. AIR TESi NOT PERMITTED. REMOVE DIRT AND DEBRIS PS WORK PROGRESSES. PLUG OPEN ENDS EACH DAY WHEN WORK STOPS. SANITARY WASTENENT BELOWGRADE PVC SCHEDULE 40 ASTM D1784 2" lHRU 6" PVC DWI/ ASTM D2665 SOLVENT CEMENT ASTM D2564 COMPLY WITH ASTM D2321. SANITARY TEES AND SHORT-SWEEP FTTTlNGS NOT PERMITTED NOT APPUCABlE NOt APPLICABL, t.si WITH WATER At 1O' HE'AD FOR 2 HOURS. Al� TES T NOT PERMITTED. REMOVE DIRT AND DEBRIS PS WORK PROGRESSES. PLUG OPEN ENDS EACH DAY WHEN WORK STOPS. NATURAL GAS ABOVE GRADE BLACK STIEL BLACK STEEL SCHEDULE 40 SCHEDULE 40 ASTM A53 ASTM A53 1/2" lHRU 2" 2-1/2" THRU 4• MAillABL£, CLASS 15D WROUGHT STIEL ASME 816.3 ASTM A234 lHREADED WELDED A5ME 81.20.1 AWS D10.12 COMPLY WllH ! NOLI.NA FUEL GAS CODE CHAPTER 4, "G AS PIPIN G INSTAUATIONS" COMPLY WllH MSS-SP-58 I /2' TllRU 1' 0 B' SPACING, 3/8' ROD 1-1/4' lllRU 2' 0 10' SPACING, j/e' ROD 2-1/2' fHRU 3' 0 iO' SPACING, 1/2' ROD 4� 0 10 1 SPACING, s;e· �OD VERllCAL PIPE O 10' SPACING TEST WffH />JR Af 1So, WORKING PRESSURE (3 PSI MIN) FOR 24 HOURS PURGE SYSTEM TO THE OUT SIDE WIT H NATURAL GAS IN ACCORDANCE WITH ! NOLI.NA FUEL GAS CODE, SECTION 406 NATURAL GAS BELOW GRADE POLYETHYLENE SDR 11 ASTM D2513 1/2" lHRU 2" POLYETHYLENE ASTM D2683 HEAT FUSION ASTM D2657 COMPLY WllH ASTM D2774. FURNISH WllH P E/rr: STEEL LINE RIS<R AT M R AND ReGULATOR. NOT APPLICABLE 1tsf WtfH AJR Al 1 so, WORKING PRESSURE (3 PSI MIN) FOR 24 HOURS PURGE SYS'Tl'M TO lHE OUTSIDE WITH NATURAL GAS IN ACCORDANCE WITH IND!ANA FUEL GAS CODE, SECTION 406 PLUMBING EQUIPMENT SCHEDULE ELECTRICAL DATA LOAD VOLTS PHASE - - - - - - I - - CAPACITY INSTALLATION NOTES EQUAL MANUFACTURERS 40 GPM AT 12 PSI PRESSURE DROP FURNISH WITH 9i9-AG-F AIR GAP, WILKINS, FIBCO TERMINATE RELIEF OVER FLOW CHANNEL 15 GPM AT 12 PSI PRESSURE DROP FURNISH WITH 919-AG-F AIR GAP, WILKINS, FEBCO TERMINATE RELIEF OVER FLOW CHANNEL 525,000 BTUH TOTAL CONNECTED LOAD, 2 PSI INL£T, 12" W.C. OUTL£T 450,000 BTUH TOTAL CONNECTED LOAD, 2 PSI INLET, 12" W.C. OUTLET 360,000 BTUH TOTAL CONNECTED LOAD (VERIFY), 2 PSI INL£T, 7" W.C. o,m ci ')(, ORIFlCE (018-D1029-035) GREEN SPRING (071-01637-004) JI" ORIFlCE (018-01029-003) GREEN SPRING (071-01637-004) ')(, ORIFlCE (018-01029-035) GREEN SPRING (071-01637-001) SENSUS, EQUIMffiR, FlSHER, ROCKWELL SENSUS, EQUIMCTER, FISHER, ROCKWill SENSUS, EQUIMCTER, FISHER, ROCKWELL PLUMBING FIXTURE SPECIFICATIONS DESCRIPTION EQUAL MANUFACTURERS FIXTURE: COMBINATION SHOWER/FACE WASH, Pl.ASTIC SHOWER HEAD, STAINLESS STEEL EYEW/JSH BOWL FIXTURE: HAWS, BRADLEY, ENCON FIXTURE: CAST IRON, BOTTOM NO-HUB OUT l fl, J.IEDIUM DUTY, ADJUSTABLE ROUND NICKEL BRONZE BAR GRATE FlXTURE, ZURN, JOSAM FIXTURE: BRASS BODY, CHROME Pl.ATE, ASS£ 1052, HOSE THREAD OUTlET, MCTAL WHEEL HANDLE FIXTURE: J.R. SMITH, ZURN, JOSAM RfN!SibNS 3/15/24 BID SET C2024 Midwes(emEogiflL'<'fS. Inc. 802 Wes!BroactwayStreet PO. Box 295 Loogootee. lnctiana47551 DATE MARCH 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK W.A.E. PROJECT NUMBER 2020073-00 Hl.02 103 OF 126 I FIL£ NUMBER I 43963 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2