Midwestern Engineers, Inc. Plan Preview

SEAL DUCT PENETRATION ® --<' �\ THRU EXTERIOR WALL WEATHER-TIGHT 24"x36" SUPPLY AIR w/ \.....\.....\..... \.::. I I @) I I r r I / Ir I f MAKE-UP AIR UNIT (MAU-1) - MANUFACTURER HED CURB FURNIS I • . ' ·- • I GRADE . ·• . I 0 I I I 6" CONCRETE PAD ® '__) __) __) __) SECTION A-A NOT TO SCALE H_VAC PLAN.NOTES_ (D 2" WATER SUPPLY TQ HEADWtiRKs BUILQING, REFeR to DRAWING (2.Bi! FdR tONTINUAf16N, (J) INSTALl PIPE SLEEVE w/ LINK-Si;\l AT [XTERiOR WALL PeNETRATION. INSTALL MAIN SHUTOFF VALVE. 0 0 0 ® 1)," WATER DOWN TO BACKFLOW PREVENTER, 1" WATER UP THRU FLOOR. 1)," WATER DOWN TO GRIT FLUIDIZER. MAKE FINAL CONNECTION PER MANUFACTURER REQUIREMENTS. EXTEND 4" WASTE FROM FLOOR DRAIN ABOVE AND TERMINATE OVER FLOW CHANNEL. 24"x18" 316 STAINLESS STEEL SUPPLY GRILL (EQUAL TO /I.I MFG. 250H-316). MOUNT BOTTOM AT 5'-0" ABOVE FLOOR. (j) 24"x18" SUPPLY AIR DUCT UP THRU FLOOR. ® 24"x18" 316 STAINLESS STEEL SUPPLY GRILL. MOUNT BOTTOM AT 5'-6" ABOVE FLOOR. 0 24"x18" SUPPLY AIR DUCT THRU FLOOR. @) 24"x36" BULLLHEAD TEE w/ TURNING VANES. @ 1!," GAS (12" W.C.) TO MAKEUP AIR UNIT. MAKE FINAL CONNECTION w/ SHUTOFF VALVE, UNION AND DIRT-LEG. @ @ @ @ @ @ 1)\" GAS SERVICE (2 PSI). REFER TO DRAWING E2.02 FOR CONTINUATION. 24"x24" EXHAUST UP TO ROOF MOUNTED EXHAUST FAN. 24",24" EXHAUST DOWN THRU FLOOR. INSTALL 24",16" STAINLESS STEEL RETURN GRILL (EQUAL TO AJ MFG. 550H-316) AT BOTTOM 5'-0" ABOVE FLOOR. INSTALL 24"x16" STAINLESS STEEL RETURN GRILL AT BOTTOM 5'-0" ABOVE FLOOR. 1" WATER FROM BELOW. }I" WATER DOWN TO GRIT CLASSIFIER. MAKE FINAL CONNECTION PER MANUFACTURER REQUIREMENTS. 12 A - ' .. " / GAS REGULATOR (GR-1) MANUFACTURER FURNISHED CURB MAKE-UP AIR UNIT Gl (MAU-1) .. .. :: & •• -·� ·'• .:. ,'.: .·.: .- : ... :" r= 1 ---=-c== � � = 11 --=---�--=e._� - ="==- '-'=--='==-"-=;, 1 1 - _ - . - 5" CONCRETE PAD- -r . - : I :1__ ________ J. }···· .:_ ..:..�./···::< ·.. ···: · ."° . :,•.• 24"x36" SUPPLY AIR w/- - - EXTERIOR INSULATION WRAP -- -I- , - - - 9 }---+�--I X A 8 r ,, •. ..· .. . '· · � . ·-·· r ' iJ. _- • -� -�--- � ... l 1 7 - - - --- UNIT HEATER (UH-1) \ EXHAUST FAN� (EF-1) � 13 OFFSET 24"x24" DUCT AS HIGH AS POSSIBLE 14 ' ' L__J ;!E-- - - - - 0 :f _ / lPR0P0SE0 MAU CONTROL PANcL -- - - --- - - - -- ------ - - -� NEW HEADWORKS_S_ TRUCIUR_ E UPPER.LEVEL HVACPLAN l SCAbE, )\" = I'-0" 6 4'11i===--===���'f"- =· =- --=��-===== = !- REDUCED PRESSURE\ BACKFLOW PREVENTER (RPZ-1) lill=1 l �� ' 3 0 NEW HEADWORKS S TRUCTURE LOWER LEVEL HVACPLAN SCALE, )\" = 1 '-0" 1 : 15 ,-.-,, 24"x24" RA REVISIONS 3/15/24 BID SET C2024 11-lidwestcni Engineers. In�. 802 We�tBm , dw:,y Strccl P.O. Box 295 Loogoocce. lndimM 47553 DATE MARCH 2024 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK W.A.E. PROJECT NUMBER 2020073-00 H3.01 104 OF 126 I FlLE NU"BER 43962 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2