Midwestern Engineers, Inc. Plan Preview
• PANEL 100 AMPERES B 12D/208VOLTS ' 4WIRE CIRCUIT ITEM FEED NO, 1 LOWER LEVEL INTERIOR LIGHTS 3 EXrT & EXTERIOR LIGHTS 5 UPPER LEVEL RECEPTACLES 7 SPARE 9 GAS DETECTION SYSTEM ._11_ UNIT HEATER 13 15 INFLUENT SAMPLER 17 PUMPING STATION HOIST 19 SPARE 21 SPARE 23 SPARE 25 SPARE 27 SPARE 29 SPARE 31 SPARE 33 SPARE 35 SPACE 37 SPACE 39 SPACE 41 SPACE MCBMAIN CONNECTION 'PHASE KAIC WIRE AMPS POLE CU, SIZE BUS 12 20 1 A 12 20 1 B 12 20 1 C 12 20 1 A 12 20 1 B 12 20 2 C A 12 20 1 B 12 20 1 C 12 20 1 A 12 20 1 B 12 20 1 C 12 20 1 A 12 20 1 B 12 20 1 C 12 20 1 A 12 20 1 B C A B C * EXPLOSION PROOF RECEPTACLES FOR CONVENIENCE OUTLETS POLE 1 1 1 3 3 1 1 1 1 1 1 1 1 !:1FAOWQ8�S 8\!11Dlt>tG El ECrnlCAI ROOM LOCATION SURFACEMOUNTING S.E.L. AMPS WIRE CIRCUIT SIZE ITEM FEED NO, 20 12 UPPER LEVEL INTERIOR LIGHTS 2 20 12 LOWER LEVEL RECEPTACLES 4 20 12 ELECTRICAL ROOM RECEPTACLES 6 35 10 MAU ._!Q_ 12 30 10 EXHAUST FAN .Ji_ 18 20 12 SPARE 20 20 12 SPARE 22 20 12 SPARE 24 20 12 SPARE 26 20 12 SPARE 28 20 12 SPARE 30 20 12 SPARE 32 20 12 SPARE 34 SPACE 36 SPACE 38 SPACE 40 SPACE 42 NOTE: TYPED AND LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. NOTE: ELECTRICAl EQUIPMENT IN UPPER AND LOWER LEVEL OF HEADWORKS BUILDING IS CLASS I DIV, 11, INSTALL PER NEC ARTICLE 500, [LECTRICAL EQUIPMENT IN EL�GTRICAL ROOM IS UNCLAS$1FIED ALL POWER AND CONTROl CONDUITS SHALL BE SEALED PRIOR TO ENTERING ELECTRICAL ROOM, • . • • I • • • - I �����������l I MAKE-UP AIR UNIT I ' (MAU-1) I ������� ��� J CONDUIT AND WIRE TO CONTROL PANEL <--��INFLUENT SAMPLER " .. SCREEN DRIVE MOTOR 480V-30, 3HP /, GFl 8-5 GRIT CLASSIFIER 480V-3¢, 1 HP GAS DETECTION SYSTEM 8-9��.i; A-� PROPOSED HEADWORKS/SCADA----t4 CONTROL PANEL r------------------------------ 1 ' ' ' ' MDPA-14 UH-1 ! EXHAUST I (EF-1) CONDUIT AND WIRE D TO MOTOR STARTER 8-6 PROPOSED GRIT CONTROL PANEL MDPA-13 8-8,10,12 8-14,16,18 ROF'OSE'D cXHAUST FAN MOfOR START1'R FAN z w O W � � /, /, A-17,19,21 8-6 /, PROPOSED 120/208V-3¢ 1DOA, PANEL "8" PROPOSED MAU CONTROL PAN[L NEW HEADWORKS STRUCTURE UPPER LEVEL POWER PLAN Nofl:': ALL CONDUITS IN HAZARDOUS LOCATION$ TO Bi:' PVC COATED RIGID OR ALUMINUM, SEAL PER NEC, SCALE: /4" = 1 '=0 1 ' • . . .. • . • • • .. • • • • • • .. • • '< B-9 • NOTE: FIELD lDCAfl': GAS DETECTION EQUIPMENT P�R MANUFACTURcRS RECOMMENDATIONS PRIOR To INSTALLATION, •• .. . . • < • •• •• GFI B-4 CONDUIT AND WIRE TO CONTROL PANEL PER ONEUNE DIAGRAM NEW AUTOMATIC BAR SCREEN GRIT PUMP . • .. • • GAS DETECTION SYSTEM ; • • • • • • 0 • 480V-3¢, 7,5HP . .. • •• • • 8-4 GFI • • .. .. . . • . . .. . . ... • • • • 4 •• • • 4 • • • •• '· • •- . • •• . • • . • .. . • • • • . ' . , . • ONDUIT AND WIRE TO CONTROL ANEL • • • • . ' . PER ONELINE • • ..- •. •, '. ,· .-, �·.'"". ·> . •• DIAGRAM MAIN FLOW CHANNEL • . • :. . . .. • NEW HEADWORKS STRUCTURE LOWER LEVEL POWER PLAN SCALE: 1'" = 1 '-0" " • . . •, .. • ,, •, - •• • • . . • • •• • Rl:Nl51dNS 3/15/24 BID SET 02024 Midwestern Engineers. Jnc. 802 We.sl BroadwuyStreet P.O. Bo� 295 Loogootee. lndia,M 47553 DATE MARCH 2024 DESIGN A.F,8, DRAWN C.N.M. Q.C. CHECK W,A.E, PROJECT NUMBER 2020073-00 E3.01 108 OF 126 I F1L£ NUMBER . *** I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2