PANEL 800 AMPERES MDPJI 277/480 VOLTS "- WIRE CIRCUIT I NO. ITEM FEED 1 WET WEATHER FILTER CONTROL PANEL 3 FEED TO n MOPB n 5 UV PDC #2 7 WET WEATHER PUMP #1 9 WET WEATHER PUMP {13 1 1 PROCESS PUMP #2 1 3 GRIT REMOVAL CONTROL PANEL MlOMAIN CONNECTION ,; PHASE KAIC WIRE AMPS POLE cu. SIZE BUS 6 60 3 A B C 3/0 400 3 A B C 10 20 3 A B C 6 BO 3 A B C 6 BO 3 A B C 12 20 3 A B C 10 30 3 A B C POLE 3 3 3 3 3 3 3 W.FT WEATc:lEB Ell!EB SlJR FACEMOUNTING S.E.l. BUi i D l �G E I EC AMPS WIRE ITEM FEED SIZE 125 2 75'10/A TRANSFORMER 20 10 UV POC #1 20 12 UV HSC BO 6 WET WEATHER PUMP {12 20 1 2 PROCESS PUMP #1 15 12 SCUM PUMP 30 1 0 SCREEN DRIVE RM LOCATION 1 CIRCUIT NO. 2 4 6 B 10 12 14 NOTE, lYPED AND LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. PANEL A CIRCUIT NO. 1 LIGHTS 200 AMPERES 120/208 VOLTS 4WIRE ITEM FEED 3 ELECTRICAL ROOM RECEPTACLES 5 BACKWASH FLOW METER 7 MINI-SPLIT SYSTEM ...ll... GENERATOR BLOCK HEATER 1 3 15 FLOW METER TOTALIZER (WET WEA.J ...1L 1 9 21 23 25 27 29 .31 3 3 _ 35 at _jg 41_ PANEL nB" FEED GAS DETECTION SYSTEM EFFLUENT SAMPLER WET WEATHER FILTER BLDG. SPARE SPARE - SPARE - SPACE SPACE_ seAtE SPACE - - . - - .. - - .. - - - - ----· - - SCADA -- - -- --·- - - - - -- - - • EXPlOSION PROOF RECEfTACLE£ MCBMAINCONNECTION ,;PHASE KAIC WIRE AMPS POLE SIZE 12 12 12 10 12 12 2 12 12 12 12 1. _ 12 _ -- - - --- -- .. - --- 20 20 20 30 20 20 100 20 20 20 20 20 20 - --·· - - - 1 1 1 2 2 1 3 1 1 1 I 1 - I - - ----- cu. BUS A B C A B C A B C A B C A B C _A L. IL .A ... _8 - j; POLE 1 1 3 1 3 1 1 1 1 1 1 J I WFT WEATc:lER Ell!EB B!JIID l �GE I EC RM LOCATION SlJRFACEMOUNTING S.E.L. AMPS WIRE ITEM FEED SIZE 20 12 FILTER ROOM RECEPTACLES 20 12 EXTERIOR RECEPTACLES 30 10 FILTER ROOM EXHAUST FAN 20 12 GENERATOR BATIERY CHARGER 20 12 MAKE UP AIR UNIT I CIRCUIT NO. 2 4 � J_ 10 12 ,J.!_ � 18 20 1 2 EFFLUENT FLOW METER CONTROLLER 20 20 12 UV sec PANEL 22 20 1 2 " LJJ .,r:-,-,:-r:, Tf"\TAI ,"7t:"l:I (p 24 20 1 2 UV EFFLUENT CONV. OUTLET 26 20 1 2 UV EFFLUENT FLOOD LIGHTS 28 20 12 SPARE 30 20 .12 SPARE 32 _ 20. I.L 5P...\RE - - - - _,; 3 6 -- -· --- SPAC& .. -- - -- SPACE -- - SPACE - -- - - SP.ACE_ - - - - -- - - 38 4Q �2_ Nore, iYPED AND LAMINATED PANEL SGH(DUlE§ SHALL ii� APPLIED At toMPlETIQN OF PROJ�Cl TRANSFORMER BY NIPSCO, PAD AND METERING BY CONTRACTOR (SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION) . PROPOSED 500KW STANDBY DIESEL GENERATOR IN STANDARD WEATHERPROOF ENCLOSURE PROVIDED AND INSTALLED BY CONTRACTOR, SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION * r------, � CONDUIT AND WIRE TO CONTROL PANEL MAKE-UP AIR UNIT (MAU-2) L_____ .J #3/0 BARE CU. GND. IN CONDUIT EXOTHERMICALLY WELDED TO (3) Y."ox1 o· CU. CLAD GND. RODS ON 1Q' TRIANGULAR SPACING 2 RUNS 4" CONDUIT A GFI -4 WP L (4) #300 MCM THWN J (1) #1/0 CU. GND. f---EI---E E E- -E- -E f--�E- -E- -E---E--�E- . -1--E - -E- -E---E-- - E---E--+--E -t--E E E --E---E -+-� 2 RUNS ] (4) #600 MCM THWN 4" CONDUIT GFI 2 A- II\ /I\ � � ,,.--., MANUAL NOTE, ALL CONDUITS IN HAZARDOUS LOCATIONS TO BE PVC COATED RIGID OR ALUMINUM, SEAL PER NEC. BACKWASH PUMP (480V-3o, 20HP, 27 FLA) GFl A-2 ( PDWER WIRING IN CONDUIT TO WWCP �BACKWASH VACUUM GAUGE AND VACUUM TRANSMITTER . . DISCHARGE 4" BACKWASH - . . VALVE FLOW METER I A-5 I /'\ ,,----..._ m "",;_ I I - .. Ill 11J: I 0 - - I \ r '-./w - I MANUAL . . ( ( � ' . . RECIRCULATION � - VALVE (Cl v' 6" BACKWASH /_ ELECTRIC .. - 1 20V+GND. IN VALVE (lYP.) CDN r u TO WWCP � � I'\- - 120V+GND. IN � 'CONDUIT TO WWCP / I I ( n [/ ,= I I I I C ··1 e� J - - � � � ;l[==- '-Pn E1 = POWER/CONTROL WIRING , =p 111 _ £ L" � CONDUIT TO WWCP 1 IN JUNCTION BOX - -� - - � / ,, ' I I I I I I I I I I J_ I I I I I I I c::!:::::=::::!:::i I � I n I In c:;L -�::::i Ill ·F -i;::_, I u ·n LI I I r----3::-_ ..J: ---1 L I I 1-1� I ( IL- -- - __J LI I I E::i:=:: �:::i I I I I I I ' I f::;::;.�:;:i I \ 1n I �In � � - .r ::l , 111 T' �-nu i- 1Y . • • • \ I .Lrr 1 ---- F --""""1 fF- . ,/ �L L "--- F �F---� �·� ' ··- ..,.__ . - --'---' - -� 0 12DV + GNli. IN , CONDUIT fo WWCP ' 0 6'' DRAiN ��"- ELECTRIC VALVE I) - PROPOSED WET WEATHER FI L TER CONTROL PANEL (WWCP) MDPA-1 f---PROPOSED BOOA-3P SERVICE ENTRANCE RATED, AUTOMATIC TRANSFER SWITCH A-3 \..s" SCUM ELECTRIC VALVE (lYP.) - - - I - � - I f-- f-- - - • • F - - � - - F � - -- - - f--- • • I - � - - - _I - \ - - -1 = f-- - r f-- f-- • • I F F F I/ � - � - � \ - - I / - / �- I \- - � - = f--- f-- 7"'" 'dR1VE MOTOR v (480V-3o, 2HP, 3.4 FLA) f--- f-- - • • • • I I I F F - - . .I.....- - � � \ I I NOTE, ELECTRICAL EQUIPMENT IN WET WEATHER FILTER BUILDING IS r� • r • � ' . POWER WIRING IN CONDUIT TO WWCP - f-- � • • I I F - - - I CLASS I DIV. II, INSTALL PER NEC ARTICLE 500. ELECTRICAL EQUIPMENT IN ELECTRICAL RDOM IS UNCLASSIFIED. ALL POWER AND CONTROL CONDUITS SHALL BE SEALED PRIOR TO ENTERING ELECTRICAL ROOM. A-23 GAS DETECTION SYSTEM --" • PROPOSED MAU-2 CONTROL PANEL A-2 NOTE SEE E5.D4 FOR ADDITIONAL INFORMATION A-14,16,18 PROPOSED EXHAUST FAN MOTOR STARTER A-6,8,10 A-7,9 .1 CU-1 I Fl A-4 � /o 1" DIGITAL CONTROL -FLOATS, -SEAL LEAK, -OVERTEMP 480V-3o POWER SCUM PUMP CONTROL PANEL- -l---1 M EXHAUST FAN (EF-2) tv::= rM 1 / \ ' .. f CONDUIT AND WIRE n /TO MOTOR STARTER it _I ..... 1 m, f+==i: 120V + CND, IN I I I I I � ,ONtJUlf T V P �· I , , , ' I ' ' 6" SOLIDS WASTE ELECTRIC VALVE (lYP.) '\ 8 � '" MDPA- 1 2 TO SCUM PUMP WETWELL JUNCTION BOX, SEE E2.02 FOR CONTINUATION GFI 4 A­ WP PROPOSED PAD MOUNTED TRANSFORMER >- -PROPOSED 277/480V- 3 o, BODA PANELBOARD "MDPA" AH-1 V A-12 V A-11, 13 _ /HARDWIRED CONTROL - WIRING IN CONDUIT TO SCADA PER 1/0 LIST PROPOSED 75KVA---t--+--I TRANSFORMER ON 4" CONCRETE HOUSEKEEPING PAD PROPOSED 120/2DBV-3o, 20DA, PANEL "A" PROPOSED WET WEATHER PUMP #2 VFD PROPOSED WET WEATHER PUMP #1 VFD PROPOSED WET WEATHER FI L TER BUILDING SCADA RTU PROPOSED PROCESS PUMP #3 VFD PROPOSED PROCESS PUMP #1 VFD ! PROPOSED PROCESS I PUMP #2 VFD MDPA-2 A-27 MDPA-l MDPA- 8 MDPA-9 MDPA-11 PROPOSED FLOW METER MDPA- 1 o I TRANSMITTER (WET WEATHER) j w FIBER IN 2" CONDUIT 1 w TO HEADWORKS ----4 FIBER IN 2" CONDUIT TO LAB BUILDING 60A- 3 P NON-FUSIBLE DISCONNECT IN NEMA 4X S.S. ENCLOSURE (lYP. OF 3) I A- 1 5 A-24 1)1---+--l- -PROPOSED FLOW METER TRANSMITTER (PROCESS) 30A-3P NON-FUSIBLE DISCONNECT IN NEMA 4X S.S. ENCLOSURE (lYP. DF 2) 0 WET WEATHER FILTERING EQUIPMENT BUILDING POWER PLAN SCALEc )," = 1'-0" • REVISIONS 3/15/24 BID SET c2024 Midwestern Engineer:,. Inc. S02 West Bro:,dway Strc�I P.O. Box 295 Loogoot�. Indian� 47553 DATE MARCH 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK W.A.E. PROJECT NUMBER 2020073-00 E5.01 112 OF 126 I FlLE NUMBER I 43954 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2