Midwestern Engineers, Inc. Plan Preview
0 �' 0 MOTOR � CIRCUIT BREAKER 0 0 � MOTOR OPERATED VALVE -v..,J..AN TRANSFORMER .ry-yyy-y-, WET WEATHER FILTER CONTROL PANEL (WWCP) NOTES 1. INPUTS/OUTPUTS DIGITAL INPUTS: HIGH LEVEL FLOAT SWITCH BACKWASH VALVE #1 STATUS OPEN BACKWASH VALVE #1 STATUS CLOSED BACKWASH VALVE #2 STATUS OPEN BACKWASH VALVE #2 STATUS CLOSED SOLIDS WASTE VALVE #1 STATUS OPEN SOLIDS WASTE VALVE #1 STATUS CLOSED SOLIDS WASTE VALVE #2 STATUS OPEN SOLIDS WASTE VALVE #2 STATUS CLOSED SOLIDS WASTE VALVE #3 STATUS OPEN SOLIDS WASTE VALVE #3 STATUS CLOSED SCUM VALVE STATUS OPEN SCUM VALVE STATUS CLOSED DRAIN VALVE STATUS OPEN DRAIN VA L VE STATUS C L OSED DIGITAL OUTPUTS: BACKWASH VALVE #1 OPEN COMMAND BACKWASH VALVE #2 OPEN COMMAND SOLIDS WASTE VALVE #1 OPEN COMMAND SOLIDS WASTE VALVE #2 OPEN COMMAND SOLIDS WASTE VALVE #3 OPEN COMMAND SCUM VALVE OPEN COMMAND DRAIN VALVE OPEN COMMAND ANALOG INPUTS: PRESSURE TRANSMITIER BACKWASH FLOW METER BACKWASH VACUUM TRANSMITIER ETHERNET: WET WEATHER FILTER BUILDING RTU SYMBOL KEY \ ELECTRICAL DISCONNECT lvFol 8 MOTOR OVERLOAD � NORMAL L Y CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMAL L Y CLOSED NORMAL L Y CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY CLOSED NORMALLY C L OSED NORMALLY CLOSED VARIABLE FREQUENCY DRIVE PNEUMATIC OPERATED VALVE - - - - NOTE: SOME SYMBOLS MAY NOT BE APPLICABLE DRIVt MOTOR 2 HP 9ACKWASH / SOLIDS WASTE l'UMP 2D HP SHIELDED TWISTED PAIR (3) POWE'R (1) GRD. PRESSURE (2) 115V TRANSMITIER - -TANK--, (1) GRD. (3) POWER I MOUNTED 1 � HIGH LEVEL ,------------ (1) GRD. , 1 J-BOX I 't, FLOAT SWITCH ------------------�------�--------� 460 VOLT 3¢, 60 Hz )I__ (2) 4-20 me SHIELDED TWISTED PAIR VFO (4) WIRE �--�o o- -.- -- --+----'-- - - - --- -__J 60 AMP 460 VOLTS 115 VOLTS C.B. I (3) POWER (1) GRD. (2) 4-20 me SHIELDED TWISTED PAIR PLC / CONTROLS I FILT�CONTROL SYSTEM ] BY AQUA-AEROBIC SYSTEMS (8) 115V (1) GRO. 2) 115V (1) GRD. 2) 115V (1) GRD. SHIELDED TWISTED PAIR VALVES BACKWASH (2) SOLIDS WASTE (3) SCUM (1) DRAIN (1) CONTROL PANEL COMMON ALARM CONTACT REMOTE START CONTACT BACKWASH VACUUM TRANSMITIER (2) ENCLOSURE NEMA 1 WALL MOUNTED PAINTED STEEL, FACTORY ASSEMBLED AND SHIPPED LOOSE. INSTALLED BY CONTRACTOR. MUST BE LOCATED WITHIN 50 FEET OF THE PRESSURE TRANSMITIER. ______J (2) 115V (1) GRD. _______________J BACKWASH FLOW METER (2) 115V (1) GRD. STANDARD CONTROL PANEL SIZE 60" HEIGHT x 36" WIDE x 12" DEEP • TRANSDUCER D FUSE 0 DRIVE BACKWASH MOTOR PUMP WET WEATHER FILTER CONTROL PANEL (WWCP) WIRING DIAGRAM NOT TO SCALE _L ' � STARTER CONTACTOR FLOAT SWITCH !CAUTION! ""°"" PROC<E""0>-.'1H "''"'""""''""-""''"' ' '"00 """"""'""'"""""'" .... ''"' '"""'"""' - "'"''"" I RE.VISIONS 3/15/24 BID SET C2024 )\folwes!em Engin�crs. Inc. 802 w�sl Broadway Street P.O. Box 295 Loogu01te. Indiana 47553 DATE MARCH 2024 DESIGN A.F.8. DRAWN C.N.M. a.c. CHECK W.A.E. PROJECT NUMBER 2020073-00 E5.04 115 OF 126 FILE NUMBER I 43951 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2