Midwestern Engineers, Inc. Plan Preview
� C �> z0 !1 � !: " 8 :,; � i�w ,< � !.'i: ! �!:I Q rl�� f!'l" .........�g ., � "' X :Ji�m � •• .'l:! 1- - ..J <llw Jo ""o....., .. ,. � - a. - �.2:i :... ..._ ll.. 0 >U :i:: oz g � 1 >< uY -� 0 55 BLOWER BUILDING CONTROL PANEL SCADA SYSTEM NOTES SLUDGE TRANSFER PUMP AND DECANT PUMP NOTES PANEL 100 AMPERES MCBMAIN CONNECTION E�ISTll':lG BLQWE8 Bll l l0 1 1':lG L O CATION 1. THE CONTRACTO R SHALL UTIL I ZE THE O W NERS EXIS T I N G SCADA SY ST EM I N T EGRA T OR BY CON T AC TI NG NATHEN BU R KHA RT OF T ORIC E N GI N EERING A T 317-71 8 - 18 00 FOR SCOPE ANO ANY QUESTIO N S PRIO R TO B I D. THE P R OPOSED SCAOA CO N T R OL PA N EL SHALL INCLUDE, BU T NO T LIMITED T O, T HE FOLLO W ING: G) THE CONTRACTOR SHALL PROV1DE AND PE R MANE N TLY I N STALL A W EATHE R P R OOF, FEMALE, 4BDV-30, 3 POLE, 20A, LOCKI N G RECEPTACLE A T THE P U MP LOCATIO N S DESIGNA T ED (M IN . 18" ABOVE T ANK). FIELD VERIFY EXACT LOCAT I ON w/ O WN ER DU R ING CON STRU C T IO N PRIOR T O INSTALLA T ION. D CIRCUIT I 120/208 VOLTS ' .d.WIRE WIRE "iPHASE SURFACE MOUNTING KAIC S.E.L. CU. WIRE I CIRCUIT 2. A. ALLEN BRADLEY COMPACTLOG I X PLC W / EXPANS I ON 1/0. OR EQUAL 8. CON T ROL RELAY S , AS N EEDED (;} PE R MANENTLY IN STALLED, NEW SLUDGE TRANSFER P U MP F R OM DIGESTER T ANK #2 TO DIGESTER TANK #1. NO. ITEM FEED e--1-- M�N SIZE AMPS POLE B 50 3 B U S POLE AMPS SIZE ITEM FEED NO. A 1 20 12 lJGHTS & POLE LIGHT 2 C. CO N VEN I ENCE RECEPTACLE, 15-AMP D. DIG I TAL DISPLAY � B 1 20 12 RECEPTACLES 4 HARDWIRE MALE PLUG ON S U BMER SI BLE PUMP CABLE T O MATCH RECEPTACLE . E. E N CLO SUR E, W ALL-MOUN T , TYPE 1 2, PAI NT ED S T EEL F . F I BER OP T IC PA T CH PANEL 5 C 1 20 12 RECEPTACLES 5 ,..J_ EXHAUST FAN 12 15 3 A 3 20 12 HEATER J_ Q) PERMANENTLY I NSTALLED, NEW S L U DGE TRANSFE R P U MP FROM DIGESTER TANK #3 TO DIGESTER TANK #2. HARDWIRE MALE PL U G ON S U BMERS I BLE PUMP CABLE T O MA T CH RECEPTACLE. G. MA IN C I RC U I T B R EAKER cJl_ 8 H. NETWORK S W ITCH, MANAGED, 5-ETHE R NET PORTS, 2-F I BER PORTS (4) APP R OXIMATE S L U DGE T RANSFE R PUMP LOCATIO N I F MOVED FROM D I GE S TE R TA N K #3 TO E I T HER AERATION TANK. 11 C 12 I. POWER SUPPLY, 24VDC 13 FLOW METERS 12 20 1 A 1 20 12 DO CONTROLLER 14 J. SELECTOR S WIT CH, 3DMM, 3-PO S ITION, Q U ANT I TY OF TH R EE (3) @ PROPO S ED S LUDGE TRANSFER P U MP CONTROL PANEL w/ CONTACTORS, CI R C U IT BREAKE R D I SCO N NEC T , LOCAL SELECTOR S\IHCHES, PILOT LIGHT S A N D ELAP S ED T I ME METERS. I NST ALL ON AL U M I NUM UN IS TR U T RACK, FIELD VlE RI FY EXACTLY LOCATIO N w/ O W NER DURING CONSTR U CTION P RI OR TO I N STALLATIO N . 15 MAINTENANCE BARN PANEL �C 3 100 2 B 1 20 12 DO CONTROUER 16 K. TE R MINAL BLOCKS, AS NEEDED L. TVSS, 12 0 VAC M. U P S BATIE R Y BACK U P I NPUTS/O U TP U TS D I GITAL I NPU TS : AL U M FEED PUMP #1 R U N S T A T US (ON/OFF) ALUM FEED PUMP #1 R UN STATU S (ALARM) ALUM FEED P U MP #2 RU N STAT US (ON/OFF) ALUM FEED P U MP #2 R U N S TA TUS (ALA R M) AL M FEED P U MP #3 RU N S T A TU S (O N /OFF) ALUM FEED P U MP #3 R U N ST A TU S (ALARM) BLO W ER #1 - H-0-A POSITIO N BLOWER #1 - MOTOR HIGH TEMP BLOWER #1 - D I SCHA R GE AIR H I GH T EMP BLOWE R #1 - D I SCHARGE A I R H I GH PRES SUR E BLOWER #2 - H-0-A POSI TI ON BLOWER #2 - MOTOR H I GH T EMP BLOWER #2 - D IS CHARGE AIR HIGH T EMP BLOWER #2 - DI S CHA R GE A I R H I GH PRESS U RE BLO W E R #3 H-0-A POS I TIO N B L O W ER #3 - MOTOR H I GH T EMP BLO W E R #3 - DI S CHARGE AI R H I GH TEMP BLO W ER #3 - DISCHA R GE AIR HIGH PRESSURE W ASTE SLUDGE P U MP #1 R U N STA TUS (O N /OFF) W AS T E S LUDGE P U MP #1 RUN STATUS (ALARM) W A ST E S LUDGE PUMP #2 R UN S T A T US (O N /OFF) W ASTE SL U DGE PUMP #2 R U N STA TU S (ALA R M) DIGI T AL O UT P U TS: INFL U E N T W ETWELL CLARIFIER I N FL U ENT � 17 C 1 20 12 SPARE 18 N OTE: TYPED AND LAMINATED PANEL S CHEDULE S S HALL BE APPLIED A T COMPLETIO N OF PROJECT. @ PE R MANENTLY I N STALLED, NEW DIGE S TER DECA NT PUMP FROM D I GESTER TANK #3 TO CLARIF I ER TRO U GH. I I II I I II II II HARDW I RE MALE PL U G ON SUBMERSIBLE P U MP CABLE TO MATCH RECEPTACLE. ===:i V1 .'.: •., ··: · ··, I lc::::J.-- - - - - -- <:::::J c::::J . ---- ----<:- ---� >>, . '. · . ,,, J··, 1 1 11 1!::=��3 - 48DV-30 11' ::i: :l c:; 0 = 0 :::i--- - 1 ���===='===���:::::::� �= = =� l �ffl::1ll: - -:JII�::@ :::::::::::::::::::::::::::: - --- I '.':·:,.: :·':.r-:: ,,::c:::i::(<:)1 1 1 1 BLO W ER ,,: WP ,. LOCAL MA NU AL COMBINA T ION MOTO R ST AR T ER I I >°.' .' : ,,. ..J:_I 1 11 1 CONT R OL ! 1 P , · . · , . A ! , � . . · . E . · ,. L , . . rT\ , . . , . · . . . : DI S CONNEC T FOR N EW DECAN T PUMP (F I ELD I I ·'> • ." ·, . ,. ,:J:J 1 11 1 V !==:i-VE RI FY EXACT LOCATIO N w/ OWNER D U RI N G I c===>-----1 f----{==:/f' · ,· ·I 'I 1 11 1 c::: :I lit>.:..:.:,· : CONSTR U CTION P R IO R TO INSTALLAT I ON) : : \ :;, , ·::i : : 1 : 1 : 1 : 1 I I ,,-' ' l ' I 1 1-,(,,· 1 1 ·:, >I. I 1 11 Li' ' I == -"' 1 f---== : : _."': ' . ,_ 11. I 1 11 :r ,: ,, ··• I I . · .. . I 1 11 r, . . . I . . , [ I 1 11 : 1 ' ; · _ '. : t : ·:�):f: t : : : I I E X ISTING AEROBIC : : : : · �-16',:• EXlg��� T ��� 3 s 1 C ! 0- 15 l®- - -DO P R OBE E X IST l�; N � E # � ATI O N 1 - - -c = :J:: +:::: :- .r1 iii DIGESTER # 2 I I I I I I I I I J i '. ,. :@-- -DO ��DBE I 1 1 I. ::,.:,;,,:(I 1 1 1 l i · f'' OO CONTROLLER O N I Jtt- -OO CO N T R OLLE R ON 1 ',;•'.J·i I l l ALUM FEED P U MP # 1 CALL AL U M FEED PUMP #2 CALL ALUM FEED PUMP #3 CALL W A ST E S LUDGE P U MP #1 CALL W A ST E S LUDGE PUMP #2 CALL DIGESTE R SPLITIER STR U CT U RE I I I I ��� T ��k� C fo N D S �rD;/: U N IST R UT S T A N O J ��� T ��kE C fo ND s �l DA : c==:::i- UNISTRUT ST A� D :J 1 - - -c=::i l ', ,\i:'.l-' : : : : PER 1/0 LIST : I �ER 1/0 LI ST I I ..c . .; .: . ·. ·l·J 1 1 1 1 A N ALOG INP UTS ; BULK STORAGE TANK LEVEL RA S FLO W METER I NS TANTA N EOUS FLO W WAS FLOW METER I N S T ANTANEO U S FLO W D I SSOLVED OXYGE N CONCENTRATIO N D I SSOLVED O X YGE N CONCENTRA TI ON ANALOC DUTPU1S: ALUM FKED P U M� #I f'AGING M,NA, A,uM Fern PUMP U2 PACiNe �IONAl ALiJl.i iTEil PUM!l fi i'Ac1N� SitiNAl tf��RNct: BLO W ER #1 vro BLO W ER #2 VFD BLOWER #3 VFD F I BER: LAB B U ILDING NETWORK RTU RA S /WAS CO NT ROL PA N EL V I A EXIS T I N G METE R VIA EXIST IN G METER VIA NEW DO PROBE VIA NEW DO PROBE 1 Ii- , -:. , • I I : ·:,:c:.r: 1 11 1 1 . :. ·· . ll ::- . , •. ', ·· · . · .• · ,• .. · . -. ':.· . ·•.: . . · . ·· ·· · · · · .· ·. :. : I i==- - __; ����= = ��� I ����==��� 1 --- -c=jl ... , ,. I' [ 1 11 1 ;:: ;:: I ;:.; ·>i· • 1 .. 1 : : , . '·: I I I : . ,. · : . •. : '· ':- '. , .: 1 1 II 1 r · .·· I I . . · .. . , LI I I . ,' , .. I I · . . ' ' ' I . I I 1 t { ', <* I I ==- --1 -- --c=:::jl . </i,' · :.> . · ,, 1 11 1 l· . y 1 : == -� f- - -== I :.c· : '': 1 1 11 1 iJl�GEi PACEO OFF Wef WEA'fHER r,ow MCTER llMAlL; PAeEO OFF PROCi::illi FLOW METER §MALL; PAGED QFF PROc.;m:: FLOW Marn / :, WP· I r,\ I I r.\ I · ,' · · ,'C; 1 1 11 1 (:>,'·,100 I t ()� 1· I ' 111 i,<,:·I I I l.:>>:<li 11 1 ,1,: , . : · .. . - 1 ! ==-- l --c:= I - I ==- - -1----c=jf·· · , , '] 11 1 [ ��T_"�_ i..;;;,,·"' 0 "'�9=�=J: ff_-� � - --_ - _- _ - _ - _ - _ -_:- _ - -�� __ - _ - _ -:__ - _ _ � _-_-_-_ _ l_ - _=- -- - � _: -=- -=--=--=--=--=--=--=--=--=--=- _ _ ___ _ ___ _ _ _ : '.:::·<�f- iil_____ �::::":::'.:'.'.":'::"".'::'."'::�".:'."'.:::::"::f1::"".'::'."'::5L:'.'.":':::'.::::'::"".".:'."'.:::::"::f�rr::::::":::".:'."'.:::::"5E::"".::::'::"'.�t==i ;;;;::;; ;:;;;::;;;::;;;:;;;::;;:;;;::;;:;;;;:::;;;::;;;:;;;:;;;::;;;:;;;:;f� �===== 1] L-_ f.l- • • • - --------------- _____ �- � � � = = _j =··-- �t X I S T IN G ; LUD ;f RA �;E;� = :'i"j - -�� - -- P;O;;;�D�S�Gt -� � I J j::-_-_::::,-: :.;:::::=:::::_-_-:::::::: :- _-:PUMP CONTROL PANELS, 48DV-30 T O '5' _ · TRA N SFER P U MP -- - ---------------------------- L � -:_ _lj- ------------- ·TT �- . _ RECEPTACLES, CONDUIT B LOWER '\::/) ,,.....- -:_ CONT R OL PANE& I i i � � � ANO W IRE TO BE REMOVED CONTROL P5,NEL - IJ 1 1 -.... ......._ _...- 1, ' ,-..._ --- ! 'l::{' -._ ...._ - -- - - - ' I j , -- g __ T,, 1 ,r = = = tf�,-,n 1 :1 1 1 1 � � � � � � T .: - �- - - Ii ('!J y---r 1: 1= -- -- - ------- - -" --- -1----�· ,---------, I ,-------1 I I I I CON T ROL WI RING IN CO N DUIT TO I [ BLO W E R CO NT ROL PANEL PE R 1/0 LIS T I': =tM!l=t :t: i' , - , - l [c========� I I I I I I I I I .t=== I I PROPO S ED J U NC T IO N BOX-- - - -� 1 -' ��TWO EXI STI NG D I GESTE R J_ -- -l_ I i_,.,,. -.. I I I I EXIST I NG RAS FLOW- -+-+--oQ METER TO REMAIN '5bM-+-- -EX I S T ING W AS FLO W [:=�� � )' r W AS T E P U MPS TO R EMA IN - / � �.. :, ...,=�·--=--� '.! (5HP, 480V-30, 7.6 FLA) EXISTING AEROB I C --... c::___ _ ___ 1:, ,.,.., - --- 1 11 � PROPOS(o �;CTRICAL DIG E ST E R # 1 L ' ' '�' � I 11 - - CONNECT I ONS TO EX I S T ING '' � c::===;::====j::i ""' __.. , , .. - .,..-- WASTE SLUDGE PUMPS --...---.. .. . ._ . .. ._ t I I I I I I I I I I I I I I I I I I I I I I I I I I I t_ (!�:: '--I,] I I I I I I METER TO REMA I N "--·--·-1 tt .::::::: ______________________- ------------- --"::- I I L________J I L__ _ _J IL L_ - -_-__ -J=� _J � "- --- ::; - -- 1 " CONDU I T w/ CON T ROL L ----- ---- ---- _________________________ _J EX IST ING BLO W ER / P U MP CONTROL PA N EL, COND U IT ANO W I R ING TO BE REMOVED , ,-< rr - -_7_-z- -z-L- :z-..z: :z_- z _- z:,J 1 /...- W I RI NG PE R BLOWER CON TR OL PANEL 1/0 LIST /' EXIS T ING 15KVA T RANSFORMrn--i-J�='\i '- - -�--L- - - - - - - - r ! .. , , , /' T O REMA I N � ..,, I '\ . ,.'" ........ ---- - - --- - --- , ,- < 480V-3¢, 3W PRIMARY I , /Iii!=-='! , I ', ' ,, I r- r -- 1 - ---- · , -- 1 .........�.........- 12D/20 8 V-30, 4 W SECO N DARY r I h_ l ' ' ..,, , .. ,, I ' , r .. _....... EX IST ING 12D/208V-3 . I MDPB-14. 1 5. 18 v · 1 · 1 " , , I I I I I , 1 ,__ J ,__J --- · --- · / · PANEL "O" T O R EMAI N V ; .., , . --- - --- "LJ , I I I I /' 1- I ' I l I f": /' EXIS TI NG CONDU I T AND 1 1 VE N T FA N S I NTERLOCKED VIA I I /' WIR ING TO REMA IN , • P R OPOSED BLO W E R CO N TROL PA N EL I I _, -�l /' RECO NN ECT PROPOSED · 1 1 1 [ '---EX I S T ING EXHA UST FAN T O R EMAI N /' BLO W E R S AS S HO WN • I · I , ,-< "I ,,_-,--,, Ir' /<,,- j. l 6g�;:gt :���� �R C ����� T 1j� ��� WER : d 14 : -'- - - - -- EX IST ING EXHA U ST FA N MOTOR /' I L _J L /" - _J � � l---- _J LI _.............. t. ·· 1 BLO W ER #3 BLO W ER #2 ,�L§WER #1 I I H STA R TE R /D I SCO N NECT TO REMAIN /' I • 7 /' HI N GED COVE R I NST ALL CLA SS I D I V. 11 R ATED CO N D U IT S EALOFFS FROM CONTROL PANEL T O JU N CT I ON BOX SIZED BY CO NT RACTOR JUNCTION DOI 1llTIIVENTS NEIi .i.il S.S. PROPOSED BLO W E R CO N TROL PANEL · )," II ;7' ;· /' • 0 1 · 1 ..''/' , ,(A'' • � I ..,, • ,!\.// I / SA W CU T , REMOVE AND REPLACE , ,- EXISTI N G PUMP- -t' ··;, · f - - -/ ,:• 1 CABLES T O BE EXIS TI NG U NI T HEI EAI T T DERi =====- -r=-. · 1 I MDPB-26, 28 , 30 / .dl'' . I A FLOO R TO R U N NEW POWER /' RE U SED -, .. , PO W ER DIS T R I B UTI ON BLOCK S MO U NTED T O BACKPANEL INS I DE JUNCTION BOX I NSTALL CABLE G R IP S TO S UPPOR T CABLE O U T OF J UN C TI O N BOX (TYP.) VENTED AL U MIN U M WIRE MESH CABLE GUA R D w/ PAD LOCKABLE ACCESS , · . � · �:< ;,., ,, CORE DRILLED ENTRY TO W ETWELL (TYP.) T O R EMAI N I J ,• .:' .:' '}±_¢ _-_ • V j A N D CONTROL TO PROPOSED ,, - " , , - • ..,,, /' �I _J BLO W ER S A S INDICATED � .--- . --- �z l z· 12m.- _:z:-z:-_z_:t] ---· 1" SPARE CONDUIT TO '" 1 >- I +l- - 2" CONDUIT e w _/_ F t B _ ER _, _ E st-ow - ER - VF - o, '- sE - E 0 - NE_ ,_,_,_,_,_, CHEMICAL FEED BU I LDING, ; • ;1· TO LAB BU I LDI N G LI N E DIAGRAM FO R CAPPED FOR FUTURE U SE "',.(,"' ADDITIO N AL I N FORMA T ION TWO 1" CONDU IT S w/ CON T ROL______.- ............_2" COND UI T w/ F I BER T O (TYP. OF 3) 0 ��� ? � \ ·1 - � G BLOWER BUILDING ELECTRICAL PLAN WASTE SLUDGE PUMP JUNCTION BOX DETAIL W I R ING PER CHEM I CAL FEED BUILD I NG RA S/ W AS CONTROL PANEL R TU 1/0 LIST (DIGITAL ANO ANA L OG) NO T T O S CALE o•�========================================================================================================================================================================================================================================::::::::::::::i < c - REVISIONS 3/15/24 BID SET C2024 Midwe,1ern Engineers. Inc. 802 We,;tBroadway Strec1 P.O. Box 295 Loogootee Indiana 47553 DATE MARCH 2024 DESIGN A.F,8. DRAWN C.N.M. Q.C. CHECK W.A.E. PROJECT NUMBER 2020073-00 El0.01 119 OF 126 I Fllf NUMBER 43947 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2