Midwestern Engineers, Inc. Plan Preview
PANEL 60 AMPERES MCBMAIN CONNECTION Ct:IEMICA I EEED RlJI I DINGLOCATION E 120/208VOLTS 1 PHASE SURFACE MOUNTING � WIRE SQ 0KAIC S.E.L. CIRCUIT WIRE CU. WIRE I CIRCUIT NO ITEM FEED SIZE AMPS POLE BUS POLE AMPS SIZE ITEM FEED NO. 1 LIGHTS AND EXHAUST FAN 12 20 1 A 1 20 12 RECEPTACLES 3 SUMP PUMP RECEPTACLE 12 20 1 B 1 20 12 METERING PUMP SKID 5 HEAT TRACE 12 20 1 C 1 20 12 PRECISION DIGITAL DISPLAY 7 SPARE 12 20 1 A 1 20 12 SPARE 9 SPARE 12 20 1 B 1 20 12 SPARE 11 SPARE 12 20 1 C 1 20 12 SPARE NOTE, TYPED AND LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. CHEMICAL FEED BUILDING SCADA SYSTEM NOTES 1. THE CONTRACTOR SHALL UTILIZE THE OWNERS EXISTING SCADA SYSTEM INTEGRATOR BY CONTACTING NATHEN BURKHART OF TORIC ENGINEERING AT 317-71 8 -1 8 00 FOR SCOPE AND ANY QUESTIONS PRIOR TO BIO. THE PROPOSED SCAOA CONTROL PANEL SHALL INCLUDE, BUT NOT LIMITED TO, THE FOLLOWING, A ALLEN BRADLEY COMPACTLOGIX PLC W/ EXPANSION 1/0. OR EQUAL B. CONTROL RELAYS, AS NEEDED C. CONVENIENCE RECEPTACLE, 15-AMP D. DIGITAL DISPLAY E. ENCLOSURE, WALL-MOUNT, TYPE 12, PAINTED STEEL F. FIBER OPTIC PATCH PANEL G. MAIN CIRCUIT BREAKER H. NE1WORK SWITCH, MANAGED, 6-ETHERNET PORTS, 2-FIBER PORTS I. POWER SUPPLY, 24VDC J. SELECTOR SWITCH, 30MM, 3-POSITION, QUANTITY OF THREE (3) K. TERMINAL BLOCKS, AS NEEDED L. TVSS, 120VAC M. UPS BATTERY BACKUP N. UL 50BA LISTING 2. INPUTS/OUTPUTS DIGITAL INPUTS, ALUM FEED PUMP ALUM FEED PUMP ALUM FEED PUMP ALUM FEED PUMP ALUM FEED PUMP #1 #1 #2 #2 #3 RUN RUN RUN RUN RUN STATUS STATUS STATUS STATUS STATUS ALUM FEED PUMP #3 RUN STATUS ALUM FEED LINE HEAT TRACE DIGITAL OUTPUTS, ALUM FEED PUMP #1 CALL ALUM FEED PUMP #2 CALL ALUM FEED PUMP Q3 CALL ANALOG INi'UiS: BULK ST0RAGK TANK lEYtL ANALOG bUfl'Uru: FAIL (ON/OFF) (ALARM) (ON/OFF) (ALARM) (ON/OFF) (ALARM) INFLUENT WE1WELL CLARIFIER INFLUENT DIGESTER SPLITTER STRUCTURE VIA Ni,;W RADAR LEVEL SENMR ALUM nm i'IJMi' #i i'AGING SIONAb ALUM F[Eli i'UMi' #2 PACING SIGNAL ALUM i'tirn F'Ui.li' fj i'ACING SIGNAL LARGE: PAGED OFF W.:t WEAfHrn FLOW MEIER �MALb; �ACED tiFF PRQCES� FLOW McTER �MALk; PACED GFF PROCESS FCOW MEffR 2 4 6 8 10 12 PANEL G CIRCUIT I NO. 1 LIGHT 3 N. WALL 5 S. WALL SPACE 9 SPACE 11 SPACE 13 SPACE 15 SPACE 17 SPACE 19 SPACE 100 AMPERES 120/208 VOLTS .)WIRE ITEM FEED MC8 MAIN CONNECTION 1 PHASE KAIC WIRE AMPS POLE cu. SIZE BUS 12 20 1 A 12 20 1 B 12 20 1 A B A B A B A B EXISi l �G MAl�IrnA�CE BARN LOCATION SURFACE MOUNTING S.E.L. POLE AMPS WIRE ITEM FEED CIRCUIT SIZE NO 1 20 12 GARAGE DOOR OPENER 2 1 20 12 FURNACE 4 2 60 6 CHEMICAL FEED BUILDING 6 PANEL "E" FEED 8 SPACE 10 SPACE 12 SPACE 14 SPACE 16 SPACE 18 SPACE 20 NOTE, TYPED AND LAMINATED PANEL SCHEDULES SHALL BE APPLIED AT COMPLETION OF PROJECT. HVAC PLAN NOTES (,\ 15"x15" WALL OPENING w/ BACKDRAFT DAMPER (FURNISHED BY FAN 'J MFR.) BOTTOM OF OPENING TO BE 9'-0" ABOVE BULK TANK FLOOR. 0 0 8 ® © INSTALL UNIT HEATER w/ MFR. FURNISHED WALL MOUNTING BRACKET AND w/ BOTTOM 7'-o" ABOVE FLOOR. 24"x24" INTAKE LOUVER AND DAMPER EQUAL TO GREENHECK ESD-435 AND VCD-40. INTER L OCK MOTORIZED DAMPER w/ EXHAUST FAN. BOTTOM OF OPENING TO BE 5'-0" ABOVE FLOOR. 1)',," WATER SUPPLY UP THRU FLOOR. INSTALL SHUTOFF VA L VE. 1)',," WATER SUPPLY TO CHEMICAL FEED BUILDING. REFER TO DRAWING E2.02 FOR CONTINUATION. SWITCH SEPARATELY FROM LIGHTS. MANUFACTURER SUPPLIED TERMINAL BOX FOR 120V-10 POWER (E-4) AND CONTROL PER 1/0 LIST ALUM FEED TUBING IN 3" CARRIER PIPE r t---· -�--- (3) #6 THWN (1) #10 CU. GN J . 1" CONDUIT TO MAINTENANCE BARN PANEL "G" ,-, ' 1" CONDUIT w/ DIGITAL 1/0 TO BLOWER CONTROL PANEL ' WALL MOUNT Ml:'itRINO PUM� SKiiJ n---PANEL "E" !""- -- E-6 i iei--#G-6, 8 !----HEAT TRACE CONTROLLER ret---�E-5 I CONTROL WIRE IN CONDUIT TO SCADA PER 1/0 "A" .-,--, �·-] ' ' 1------ILOCAL OPERATOR STATION FOR CHEM FEED CONTROLS CHEMICAL FEED ROOM TO INFLUENT 1" CONDUIT w/ ANALOG 1/0 TO BLOWER CONTROL PANEL l--•-J 1" SPARE CONDUIT CAPPED FOR FUTURE USE E 3 }---I MDPB-20,22,24 2 UNIT HEATER -----+-+-�"(UH-2) PUMP STATION • .. • • • • .. . . E-1 • .. . '· . . . • . • . . . . . • . • . . . • • ' • • • ... •• . • • . . . . • • • • .• LIGHT FIXTURE SCHEDULE Type Manufacturer / Model Mounting Lamps A COLUMBIA - LXEM4-40HL-RFA-EDU-SSL XEHC SURFACE 47.4W LED B EXO - LNC2-4 8 L-4S-4K7-4W-UNV-DBT-PC SURFACE 45W LED C EXO - WGH2-LSCS SURFACE sow D EXO - SGD-6D-LSCS-GR ARM 56.9W LED E HUBBELL - FML-20L-52-4K-W-U-K KNUCKLE 52W LED H A RED SKY - LNR-80-10D-277-4K-H2-DP-GRY-PEND PENDANT 8 0W LED HB DUAL LITE - SEWLSRWE-CID2 SURFACE 3.1W LED NOTE, CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS, BRACKETS, CABLES, PHOTOCELLS, ETC. FOR FULLY FUNCTIONAL SYSTEM. MANUFACTURER OR ENGINEER APPROVED EQUAL. ' . . . ' • GENERAL HEAT TRACE NOTES 1. SELF REGULATING HEAT TAPE SHALL BE WRAPPED AND SECURED AROUND THE CHEMICAL FEED TUBING WITHIN THE 3" CARRIER PIPE TO PREVENT FREEZING. THE CONTRACTOR SHALL ORDER THE HEAT TRACE CABLING TO LENGTH ONCE THE ALUM FEED LINES INDICATED ARE INSTALLED AND LENGTHS CAN BE DETERMINED. PROVIDE AND INSTALL w/ ALL REQUIRED TAPING, STRAPPING, 10401 CONTROLLER, END SEALS, POWER KITS, CONNECTION/JUNCTION/PULL BOXES, THERMOSTATS, TERMINATIONS AND SW/FOOT SELF REGULATING HEATING CABLE PER MANUFACTURERS RECOMMENDATIONS AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. 2. THE CONTRACTOR SHALL MEGGER TEST THE HEAT TRACE CABLING PER THE MANUFACTURERS RECOMMENDATIONS AFTER IT IS INSTALLED TO ENSURE NO DAMAGE WAS DONE DURING INSTALLATION. 3. THE HEAT TRACE DESIGN WAS COMPLETED BY RELCON, WHILE IT IS NOT REQUIRED IT IS RECOMMENDED THAT THE CONTRACTOR CONTACT JACK HOLMES AT (317) 8 42-0505 FOR PRICING PRIOR TO BID. MOUNT AT FLOOR LEVEL OUT OF CONTAINMENT RADAR LEVEL--�ill) SENSOR CONTROL WIRING IN CONDUIT TO SCADA PER 1/0 LIST / / "A" BULK CHEMICAL STORAGE TANK / / / E-2 E-1 MOUNT AT 8'-0" A.F.F. Tl rrrn1 1 rr 11r111r • �...iE-1 . . • • .. • • • MOUNT AT • 4 • 8'-0". A.F.F.. • • • . ' • • • . . . ·.i; . • : • . .• .... .. .•· • • . . .. • . . .. . . . . ·- 4 ... .• :: ' .. . · • � . . . . . • • • • • • , .. . " " . . • • .. .. .. . . .•.- 4 ' . .. • • . . ... . . · . • • - . • . •• . .. . . . . .• . 'I I ' • • .. • _• . • .4 • - • . ' . . ,, . . .· . • • . . • • . . • • . . ·-· . . ' • •' . .. . ... . . , . --- -txHAUSf FAN (c,-4) CHEMICAL FEED BUILDING ELECTRICAL PLAN SCALE: Y," � 1'-0" • u t:: - REVISIONS 3/15/24 BID SET C2024 Mictwest(·m Engineer,;, Inc. S02 \Vesi Broadway Slri.:cl P.O. Box 295 Loogoo!ee. lnciiana 47.'i5� DATE MARCH 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK W.A.E PROJECT NUMBER 2020073-00 E12.01 121 OF 126 I FllE NUMBER I 43945 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2