TO NEW CLARIFIER INFLUENT CHANNEL *-------'� CONTRACTOR TO REMOVE ENOUGH PIPE TO ADEQUATELY INSTALL 14" M.J.D.I. 90' BEND, PIPE END CAP AND CONCRETE THRUST BLOCKING AS INDICATED EXISTING 14" D.I. EFFLUENT LINE EXISTING CLARIFIER No.1 AND No.2 EQUIPMENT DEMOLITION - PLAN VIEW NOTE . 1. ALL INTERIOR EQUIPMENT TO BE REMOVED FOR CLARIFIER No.1 AND CLARIFIER No.2. CONSULT WITH OWNER THE SCHEDULING OF EQUIPMENT REMOVAL. SCALE: 1/4" = 1'-0" NUMB ER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2:l 24 26 26 2'1 28 29 30 NOTATION TABLE PIPING Existing 32' Dia. Exterior Concrete Wall to Remain Existing Influent Pipe Sleeve to be Removed and Wall Opening To Be Grout Filled. Existing 14" Dia. Effluent OpeningIn Concrete. Effluent Pipe To RemainIn Use Existing Concrete Wall to Remain in Use Existing RAS / WAS Channel to Remain in Use Existing 14" DI. Influent Line to be Abandoned in Place Existing 6" 0.1. Scum Drain Line to Remain in Use. Existing Scum Telescoping Valve to Remain in Use Existing 6" Dia. Tank Drain Plug Valve To Remain in Use Existing Scum Effluent Channel To Be AbandonedIn Place Existing 10" Dia. Scum Effluent Line To Be AbandonedIn Place • Existing Clarifier Effluent Channel To RemainIn Use Existing RAS / WAS Pumps to Be Removed Existing Concrete Wall To Remain In Use. Remove Stop Plate Existing 12" Clarifier Effluent Pipe Removed Remove Existing Stop Plate and Weir Plate. { Two Locations) Existing Equipment To Be Removed Effluent Trough Piping to Be Removed. ( Each Clarifier ) Existing Clarifier Drain Line Telescoping Valve and Plug Valve to Remarn In Use. - - . Existing Plug Valve to Remain in Use - - .·- .... - - - - - - - - - - ·-- ·- Elxi$ting Concrete Wall To 9e Removad - - -- �xisting laffluMt Opehing a. i,_d lcffiueht Pipe to Remain In Use Plug �xis!ing Pipe Opehing With Non-Shrink GFl>u! -- - - Remove Existing Grate -- - - • Existing Metal Baffi� To Be Removed Existing Fixed Davit Crane Base Existing Flushing Hydrant to RemainIn Use - - - - - - - Existing Sub. Pump Equipment "Fast Out" Equipment To Be Removed LEGEND £ CUT -= LJ :.: NE ::._:'-"�-'---J.. DRAWING NO. FOR SECTION VIEW A10 - - - - - IXXI CROSS HATCH INDICATES ITEMS TO BE REMOVED COMPLETE. CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF ALL MATERIALS AND DEBRIS ASSOCIATED WITH THE DESIGN HATCH INDICATES ITEMS TO BE ABANDONED IN PLACE - - - - REVISldNS BID SET c2024 Mirlwe.slem Engineers. Inc. S02 West Broadway Slrec! P.O. Box 295 Loogootee. Indiana 47553 DATE MARCH 2024 DESIGN M.M.S. DRAWN D.A.P. Q.C. CHECK W.A.E. PROJECT NUMBER 2020073-00 P8.01 42 OF 126 I Fll£ NUMBER I 44024 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2