Midwestern Engineers, Inc. Plan Preview
3'-10" 16 36 t 6" DI PUMP SUCT!ON LINE t FROM SLUDGE • _____ STORAGE¢ Q BAG SYSTEM ------ r ® TO SLUDGE _\ -� STORAGE •5_ BAG SYSTEM 3'-4" ,. • I CJ WATER SUP i�� -4!-. �I_,® I ! " [ ·:·:: ::·c:�c·c:· c:c. ················ • • ' ' - ' I /�1 'Y'� 13'-0" � 12' 6" - - - G) 0 I <Xl - - � \\,/@ - - 2'-8" 6" DI FORCE MAIN FROM EX DIGESTERS -- - • pr-, ' ' ___..L......._l_ ---T ' ' ®--: ' ' ' ' ' . . ' ' .r_ @.__ ".7.'.I'.7� :II � i( ' @ 22 � • 1· 1. 32 ,A\ C ' ii IOI ' ' " - • 1 11 111 I � • I ® • ' - 1!1 • ' �. ' " ; I 1'- ' • • ' -, 6" DI SLUDGE RETURN LINE ____D e::> TO EXISTING DRYING BEDS CJ - - I 0 - n WATER SUPPLY • LINE --+-! ll ,"= - S .d. --11,, F --b..;i., • 1 2 I 16 • " 16 ,9 ;@ " 8' 0,, 11 1" PVC BACK FLOW II - II PREVENTION DEVICE -=i:IF;;;:;;;;:;;;;:;�r;;;:;;;;;;;;;:;�-- - -11-1- 1" PVC BALL VALVE - II 11 II II J 8 1-® ,_, 6) • 1 6" DI PUMP .. SUCTION LINE ' ·� -:- i·. ,. �----1: · . 1 '.:. 18 , Polymer Drurlti Polymer Oruth II 11 15 18 7 1'- 0 1 8 • T/SLAB . 891.33' ,-_' .\*· -- CONCRETE "; ';" FOUNDATION WALl. \":> ; .... ··� ·, . . 16 PIPING & EQUIPMENT SCHEDULE ITEM DESCRIPTION 1 12'-6"L x 8'-O""W x 7'-6"H MODULAR FIBERGLASS COMPOSITE BUILDING, SEE SPECS. 2 SLUDGE/FLOCCULANT MIXER w/4" SCH 80 FLANGED END CONNECTIONS 3 POLYMER METERING PUMP ON S . S. SHELF 4 POLYMER SOLUTION HOSE STORAGE COMPARTMENT 5 (2) 55 GAL DRUMS, POLYMER, ON 2 DRUM CONTAINMENT PALLET w/RAMP 6 6" x 4" 0.1. 90' REDUCING BEND AT PUMP 7 SLIP ON CASKETED 6" 150# CAST IRON FLANGE 8 6" CHECK VALVE 9 6" PLUG VALVE 10 1" CHECK VALVE 11 POLYMER INJECTION QUILL/POINT 12 2" POLYPRO BALL VALVE FOR FLOC SAMPLING 13 PUMP SUPPORT STAND 14 VAPOR BARRIER 15 COMPACTED GRANUL AR BASE MATERIAL 16 6" DI/PVC PIPE 17 6" DI FITTING WITH FLANGE ADAPTER WHEN NECESSARY 18 CONCRETE SLAB & FOUNDATION PER STRUCTURAL 19 1" PVC VENT TO OUTSIDE 20 6" DI / PVC TEE 21 6"x4" D.I. REDUCING FITTING 22 6" D.I. / PVC 90' BEND 23 6" D.I. FITTING 24 4" FLEXIBLE HOSE W/ CAM-LOCK CONNECTOR 25 METAL STORAGE CONTAINER 26 FLEXIBLE SLUDGE DEWATERING STORAGE FABRIC 27 6" PLUG VALVE 28 6" HIGH CONCRETE CURB STOP 29 )," EXPANSION JOINT REQ'D 30 OVERHEAD PIPE SUPPORT 31 REVIEW STRUCTURAL PLANS FOR ANCHORING REQUIREMENTS 32 ROTARY SLUDGE TRANSFER PUMP - 4" INF / DIS CHEMICAL TREATMENT EQUIPMENT. PLAN VIEW 6" DI BACKWASH HOLDING EFFLUENT 33 PROVIDE PIPE SUPPORT AS NECESSARY �-,, r' ' �.. ,. , .. . �-- :.. . - \" }-. ,.-. ·, ;�, ·f· : ,_ - - __ , . • •. '•i T/SLAB 16 6" DI SLUDGE RETURN LINE TOEXISTING DRYING BEDS [ ,.: ·.·.. , ..• �; . . ,.� .... '"' ,;-, .::. I ._. ·,,·: :=l ; :) ·1 /·:;t \ .?. "' . ,, ·'· '" ;: . . ,· ' . -, .,_ ,_. •'" . ,, !-•. r TO SLUDGE STORAGE .. ,,-+--''---ji--" BAG SYSTEM n _, 6" DI FORCE MAIN ------�· FROM EX. DIGESTERS 3'-4" @ - ' ' ' ' - - - - - - - ' ' ' ' SCALE: )'," = 1'-0" .. 2' 8" 1 7 ·,:: J '18' .,�- -� •:. . ;H-JC.... �:.±: .;,i :� 1'-4" . .. � :: j ., ' 6" DI PUMP '---lit--...J.�· SUCTION LINE @) 6" DI SLUDGE RETURN LINE TO EXISTING DRYING BEDS 34 SAMPLING PORT 6" DI SLUDGE RETURN LINE TO EXISTING DRYING BEDS 35 ACCESS DOOR BY BLDG. MANUFACTURER (FRP) 36 6" DI DIGESTER SLUDGE BY PASS LINE TO CHEMICAi. FffD 2 CHEMICAL STORAGE DETAIL SCALE:: 1/2" = 1 '-0" -- - --� - -- ---·----" - ---=---_ _ -_ -=------... � ---- §�ffi:- -----1 '""'9� ·o�s---t-_-_-_-_-_�·-· ��-� ------- �-------- - -_-_ - _-_-_-_-_-_-_-_-_-_-_____. _ _��_,� ·o� "' �������������������-==:-�---- - , 905 I �-�------'-"-"'-" - 1-------- - - -----------------� ---------------ro c I U)-u_,------ -1 -------- -1- - - - ----+, ---'-- - - -- - - - - \ 900 '21' 122' •, _. t--==-t�·:� - ��� --- �- - �� -- - ------ - - -,"' 24'1"®� Ii• 1 7 ) - ---------- � _.0. ( : 2 .,, s __ _, C 2 " s '-- ---@t i ;;!: µ-' 1 " 6 '-- l _ _ _ _ _ __ :;,; _-a' -11- � - 1-� - --------- - --- 1-8=9�5�::::::::::::::::::::::::::: : ::: : :�_ : --------- -- - i 1l"K___ - - ----------- � --+-I- ' <f) ,__________________[ 1 1 1 ' I \ PROVIDE METAL �-- ", , j,.--+-- ro ---- ..c m··1l1 PIPE SUPPORT � - ;-- . � : - -- - 1 900 895 890 EL �; 1 L ��$cc,_ ------' " 1 -;f'-------' 'f =- I --1- ----- 31�l �tr, AS NECESSARY �-i� • , c, c5- -- - I __ , ·: ···· ,, \ _ ' , - - '"' _ , .. , _ . _ . _ .•_ ...._ .. _ , .., _ , ·· _ · '"' ... . n ,, ,,, .. , . .. -�-..,, -�"n,,, ,.. , t" .,,,,,� 111 ' '1+ --1c' ,Y ,,.1 8s-;---J.- 8 "-' 9 '-' 0 "--- __,1 J •- - -"" r 1 .:,, s ,_____________ _,,_ ,--1 1 _ 1 r 1s1 _ L@�: 885 880 875 1---------------- - --------- - -II,-__ ' ) 17 : (16] 6" PVC PIPE - ·I - - - -I CONCRETE / • PIER SUPPORT _J 8"x6"' PVC WYE ---------- 1 , !NV. EL. 885 . 05' --- -·-----------•f:::-:!-:::::l------='-'='=:..':".:::'.c:::'.....:________ 1 D1J.O ----·�--------------------------�! BACKWASH SLUDGE DEWATERING PROFILE 885 880 875 CHEMICAL FEED STRUCTURE DETAIL 4 SCALE: 1"=10' Horiz. 1"=5' Vert. SCALE: 1/2" = 1'-0" 1 CHEMICAL FEED STRUCTURE DETAIL SCALE: 1/2" � 1'-0" CHEMICAL TREATMENT DETAILS NOTES: SCALE: AS SHOWN IT IS THE CONTRACTORS RESPONSIBILITY TO SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT, PIPING, VALVES AND APPURTENANCES FOR A FULLY OPERATIONAL CONTAINER BAG SLUDGE DEWATERING SYSTEM, INCLUDING THE CHEMICAL FEED SYSTEM . INSTALLATION SHALL BE IN ACCORDANCE TO THE MANUFACTURER'S RECOMMENDATIONS. ANCHOR BUILDING TO CONCRETE SLAB PER MANUFACTURERS RECOMMENDATION RF;VISIONS BID SET C2024 Midwc,tcm Engineers. Inc.. 802 West Bro,idway Street P . O.Bo . , 1ci5 Loogootee. Indiana 47553 DATE MARCH 2024 DESIGN M.M.S. DRAWN D.A.P. a.c. CHECK W.A.E. PROJECT NUMBER 2020073-00 P13.02 60 OF 126 I FllE NUMBER _ 44006 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2