Midwestern Engineers, Inc. Plan Preview
--� \ \ S' ii'l - - - - _/ � -----..,, � \ ,;! ' "' r-� I U I z r------- 0 / u / 0 / 6 0 I " N 2'-8" 2'-Q" ______ T_l__________ _ SEE HVAC OWG's FOR EXACT OPENING SIZE 20'-4" . , · .,. ,' . . . � . . ..... ,· . . . ' . \: \>; ·4, �'/,':";�..�::�</:".."// . <'./ . :'.}::. ., ... . . . . �.... ,;' . ·, ' . '· ... : .. , . . .. ,·· ':. COPEN TO T.O.G. = 885.79' 54'-0" [0/0 CMU] 42'-0" -- r --- ----------- r - I I ' 0 I .. ·• ,.,:·.-.� .. ' ·) ,. · .. � · ,: I' .,- '' .. . . .. , . · 6 '-3" (G) I I I I J'-4'' t-o" -- - - "' "' I "' IF.F.E. = 892.50' I WASTE REMOVAL ROOM I @) - -· - 12'-0" UPPER rLOOR PLAN SCALE: i /4" = 1 '�O" K 54'-4" [0/0 CONCRETE WALL) 83.09 42'-o" 4' - 0 " 3'-4'' ELECTRICAL 0 I .. r ROOM 3'-4" ' 0 I CXl ' ' ' ' ' 4'-o" 12'-0" SLOPE B" TYP. ----- I 1/ SLOPE ' -- - - - -� CJ) H S3.08 f .�J,i.i{:�/:·:�:'.:/�_!\/\··:/\�:,\ ··:· !:· ;·,; :,��:·\�·); � ·t�:-\/;:\t:\/�\ /.:'!'.·�t?'./(·:'</. 1 } :·t/\)?//\·�\:\.{?� ..\);: '.-:\/{::/\:·.: '. ':.. -�·.;_":_�.:_;,·:�·;.�.-/?� /·..·-,._ .:�(� ·,�· ;:�_). �,.:{:�\\ ''.·.·./Y·="-.:::_::.\ ( /(�·:_;:.·;.!t:::--t,��;:._.. : :? )/ :� . . i . '.� _ :,: '. ,.·· · . -�- . . ,.., ,,, ..,• -· ·, •;.• _ ... ,. .• ,. '-: i'. ;.· 14" TYP. 2 -· ·,.·t :, :. / E.J. ,;; )· ; ; o "I F � .F � .E�.-=-8� 8�3�.o � o�' I E.J. T.O.G. = 88B.OO' T.O.W. = 863.00' T.O.S. = 88�.oo· _________.i..._____ -+---- -------------------------�- ------------------------------ ---- ' GRIT REMOVAL ROOM � C J fFFE. = 883.00' f I. N 0 LOWER FLOOR PLAN SCALE, 1/4" = 1'-0" . .. . ... . :· ..•:.::,- . ·, . }.,·•., ,; :;· \ :-;-_ .(,\.; !; i- ./ ,., ..... - �· ·r ··r . ":. PLAN ABBREVIATION$, T.O.G. = TOP OF GRATING T.O.W. = TOP OF WALL T.O.S. = TOP OF SLAB f -- - - - � ROOM NAME ROOM No GRIT-REMOVAL RM 101 ELECTRICAL RM 201 WASTE REMOVAL RM 202 1 2 3 4 5 I ROOM FINISH SCHEDULE FLOOR BASE WALLS MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH >- z I W a' tc > CL 0 w �E w w � I C, <; z � c= >- C, 0 � w I z C, w 0 c:5 w 0 zO >- :, !!] - z 0: :, >- � ::, 0 c= "' z - ::J I ::, - w 1/) t;; > °' z :, w °' V) >- 0 >- � w � ::, .,: CL CL C: u � CL c= °' z 0 V) 0- z z � >- 0 ,;u > °' u� >- a' ::J "' C: z w z (D � V) I z CL >- >- C, :, I Q_ a' >- I t;; 00 w >- I b ,,; 0: 0: z u V) CL °' 0 0 "' 0 V) CL WU :, >- "' x- w � 0 c= � Q_ u ::J 0: 0: :, I o'z 0 z � >- >- V) "' "' >- 0 V) u u u � 0 u 0: C, w - "' 0: "' ::J 0 0: CL .,: ::, 0 w > i1 i1 X w � w i1 u u u u ::, >- w V) z 0: CL C: w z "' u: rn z X X X X X X X X X X X X X X X X X X GENERAL CONSTRUCTION NOTES IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT ALL GUARDRAILS & HANDRAILS ARE INSTALLED PER THE CURRENT EDITION OF THE ADA STANDARDS FOR ACCESSIBLE DESIGN & OSHA REQUIREMENTS. GUARDRAILING ON UPPER FLOOR SHALL BE INSTALLED 6" FROM SLAB EDGE TO CENTERLINE OF RAILING. EXTERIOR CMU ON UPPER FLOOR SHALL BE OFFSET 2" FROM THE OUTSIDE EDGE OF THE CONCRETE WALL BELOW. OUTSIDE EDGE OF CONCRETE WALL BELOW SHALL BE CHAMFERED 1j" EXCEPT AT DOORS BUT SHALL BE SLOPED TO PREVENT WATER INFILTRATION. ALL CONCRETE MIXTURES USED FOR CONTAINMENT OF LIQUIDS SHALL BE AS NOTED FOR (MIXTURES FOR TREATMENT PLANT STRUCTURES) UNDER SPEC. SECTION "Q33000-C,l,f'. COl'J.CRETE". WATERPROOFING ADMIXTURE IS NOT REQUIRED IF A LINER SYSTEM IS USED. DOOR, WINDOW, & HARDWARE SCHEDULE LOCATED ON SHEIIT "$3.1 o". I 0 0 0 0 0 0 0 0 0 @ @ . FLOOR PLAN KEYNOTES 033000-CAST-IN-PLACE CONCRETE PROPOSED INTERIOR SLAB-ON-GRADE (MIXTURE FOR BUILDING ELEMENTS) 033000-CAST-IN-PLACE CONCRETE 14" CONCRETE WALLS (MIXTURE FOR BUILDING ELEMENTS) 033000-CAST IN PLACE CONCRETE PROPOSED 4" EXTERIOR SLAB-ON-GRADE (MIXTURE FOR BUILDING ELEMENTS) Q42200 UNIT MASONRY PROPOSED 8" CMU EXTERIOR WALL 042200 UNIT MASONRY PROPOSED 8" CMU INTERIOR WALL 05�000 METAL FABRICATIONS 6" STEEL PIPE BOLLARD 055000-METAL FABRICATION$ C12x8.27 ALUM. STAIR STRINGER 055000 METAL FABRICATIONS ALUM. STAIR LANDING FRAMING MEMBERS LANDING (ALUM. CHANNELS, ANGLES, & TUBE COLUMN) 055213 PIPE !l< TU6E RAILINgS GUARDRAIL (G) OR HANDRAIL (H) 055313 SAR GRATINGS ALUMINUM GRATING 067413 FRP GRATINGS SOLID GRATING I CEILING MATERIAL FINISH I w V) w I w >- °' � I °' >- °' ::J 0 w >- ::J 0 w 0 ::J 0 0 >- °' z >- 0 >- X rn � "' 0 X :, w c= CL :, X :, w w V) >- 0 V) >- V) >- :, � CL °' I I ::J "' 0: rn >- >- w I I V) V) V) u "- z z :, V) V) - - CL c= :, - - z z a' a' - z z >- V) 0 ::J °' C: C: C, CL CL Q_ C: C: ::J w V) 0 � CL >- >- C, u >- <; <; >- >- >- °' °' z "' z C, °' 0: le le le 0 0 c= :, w w V) 15 15 :, ::, >- >- u u :s u u u x Q'. Q'. "' "' i1 "' i1 "- w z z Q_ Q_ "- X X X X X X NEW HEADWORKS BUILDING - FLOOR PLANS R�ISIONg BID SET Cl 2024 Midwestern Engineeris. Jnc. 801 West Bro;1dw11'' Str,:�l P.O. Box 295 • Loogoolt'c. lndian�47553 DATE MARCH 2024 DESIGN T.M.K. DRAWN T.M.K. Q.C. CHECK W.A.E. PROJECT NUMBER 2020073-00 S3.03 66 OF 126 I FILE NUMBER . 44000 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2