Midwestern Engineers, Inc. Plan Preview
□ ,:;;cl.,:J��-- - LED DUSK-TO-DAWN LIGHT w/ PHOTOCELL ON � WEATHER PROOF SWITCH BY DIV. IA CONTRACTOR FENCE NW OF TANK BYDIV. 1B CONTRACTOR 1¼" RIGIDALUMINUM CONDUIT PROPOSED PANEL "B"" -t+H-i AND PARKING LOT LIGHTING CONTACTOR IN 3D"x30" NEMA 4X S.S. ENCLOSURE BY DIV. IA CONTRACTOR DIV. IA ◄�--�-ao,► DIV. I I UNLES� OTHERWISE NOTED�- ,._,,._� , QUAZITE PULL ----l BOX BY DIV. I CONTRACTOR, WIRING BY DIV. IA CONTRACTOR " II 30" MIN. . . •:.: -200A-2P SERVICE ENTRANCE RATED CIRCUIT BREAKER DISCONNECT IN NEMA 4X S.S. ENCLOSURE BY DIV. I CONTRACTOR " ' 200A DOUBLE GANG METER BASE PROVIDED AND INSTALLED BY DIV. I CONTRACTOR, METERING, WIRING AND TERMINATIONS BY DUKE ENERGY 200A-2P SERVICE ENTRANCE RATED CIRCUIT BREAKER DISCONNECT IN NEMA 4X S.S. ENCLOSURE BY DIV. I CONTRACTOR -FENCE AT CORNER OF HART ST. AND BAUER DR. BY DIV. 18 CONTRACTOR (1) SPARE 2" SCH. 40 PVC CONDUIT FROM RACK TO TRANSFORMER POLE BY DIV. CONTRACTOR CAPPED FOR FUTURE USE (MIN. 36" COVER) :1---QUAZITE PULL BOX BY DIV. I CONTRACTOR, WIRING BY DIV IA CONTRACTOR (1) 2" CONDUIT FROM LIGHTINGJ CONTACTOR INSIDE TANK TO PULL BOX BY DIV. I CONTRACTOR, TANK LIGHTS WIRING BY DIV. IA CONTRACTOR (FIXTURES 5 & 6) � #4 COPPER IN 1'' ' - :;:-==f--_ J[ CONDUIT TO ¾"0x10' CU. CLAD GND. ROD INSTALLED BY DIV. I J L2" SCH. 40 PVC CONDUIT w/ PULL ROPE AND LONG SWEEP ELBOWS BY DIV. I CONTRACTOR, WIRING BY DUKE ENERGY (MIN. 36" DEEP). RISER UP TRANSFORMER POLE BY DUKE ENERGY. L(1) 2" CONDUIT FROM LIGHTING CONTACTOR INSIDE TANK TO PULL BOX BY DIV I CONTRACTOR, WIRING BY DIV. IA CONTRACTOR (3) 2" CONDUITS TO PARKING LOT ANDTANK LIGHTS BY DIV. I CONTRACTOR, WIRING BY DIV IA CONTRACTOR - PARKING LOT LIGHTS #1 - #4 - PARKING LOT VIDEO - OWNER SPARE LOCATION TYPE MOUNTING QUANTITY FIXTURE "R3" POLE 2 EA. POLE 1 - 4 FIXTURE 'V1" POLE 1 EA. POLE 5 - 8 CONTRACTOR PROPOSED ELECTRICAL RISER NOT TO SCALE LIGHT FIXTURE SCHEDULE LAMPS MANUFACTURER LIGHT MODEL # POLE MODEL # COMMENTS 70W LED HUBBELL RAR1-160L-70-4K7-4W-UNV-ASQU-LGS SSSH25-60B-2-B3-LGS-GFI 25' POLE 827W LED HUBBELL VFS-Y-126L-880-4K7-4-240-3C w/ SLIP SSSH25-60B-TA-LGS 25' POLE FITTER ADAPTER ACC-0-HLOL-VFS-MTG-SF-LGS CONTRACTOR TO UTILIZE ESL SPECTRUM FOR LIGHTING, CONTACT TRAVIS BELDEN AT (317) 223-26 3 FOR PRICING PRIOR TO BID, NO EQUAL. - ·- ... - "R3" D RIGID STEEL PVC COATE CONDUIT IN BASE TURN FOR PVC C CONCRETE ED OUT 12" ONNECTION OLTS ANCHOR B (TEMPLATE MANUFACTU BY RER) #3 CIRCULA @ 10" o.c R TIES RT. (8) #5 VE EQUALLY S BARS PACED __, 3" CLEAR AND BOTTO t SIDES \ ' . . • • . . . • .. " , - • I ' IC . • . • . • .• . . . . • ' " R.3� ·• • . . p, - • • . . . k . •. . , ' • . ,, l - .- .. . . . • • 6" SQUARE STRAIGHT STEEL POLE HAND HOLE LEAR / 1)1" C @ TOP I � __, z " • 0 I "' 2" 3" -CONDUIT & WIRE PER E LINE DIAGRAM ON ' ' )\"0 X 8'-Q' CU. CLAD GROUND ROD 2'-0" �4,000 ENTRAI PSI 6% AIR NED CONCRETE PIER FIXTURE 1 - 4 DETAIL NOT TO SCALE A '- . --, ,_ ·['� OLTS ANCHOR B (TEMPLATE MANUFACTU BY RER) D RIGID STEEL PVC COATE CONDUIT IN BASE TURN FOR PVC C CONCRETE ED OUT 12" .:£ ONNECTION #3 CIRCULA @ 10" o.c R TIES (8) #5 VER EQUALLY S T. BARS PACED .. . • . . • • • . . . .• • l\ \_,1 ,V1" ·1 6" SQUARE STRAIGHT STEEL POLE HAND HOLE / 1!," C @ TOP LEAR 2" ·• 3" .- " . • . ·• . • • z • ·� " • , 0 • I .. 3" CLEAR AND BOTTO t SIDES \ • . • ' . • ' "' • . -co ON NDUIT & WIRE PER E LINE DIAGRAM ' , )\"¢ X 8'-Q' CU. CLAD GROUND ROD " •. : 2'-o" . • • I 4,000 ENTRAI PSI 6% AIR NED CONCRETE PIER FIXTURE 5 - 8 DETAIL NOT TO SCALE CH. 80 PVC C FOR PARKING (MIN. 24" 1" SCH. 80 PVC CONDUIT AND WIRE FOR PARKING LOT LIGHTS AND 120V-1¢ CONV. OUTLETS (MIN. 24" COVER) !FIXTURE 6! ¢ ' J LIGHT FIXTURES, 1" SCH. 80 PVC CONDUIT AND WIRE FOR TANK FLOOD LIGHTING (MIN. 24" COVER) BY DIV. IA CONTRACTOR (1) 2" SCH. 80 PVC FOR PROPOSED PARKING LOT POLE LIGHTING (1) 2" SCH. 80 PVC FOR PROPOSED PARKING LOT FUTURE CAMERAS (1) 2" SCH. 80 PVC SPARE FOR FUTURE USE (1) 2" SCH. 80 PVC FOR PROPOSED PARKING LOT POLE LIGHTING (1) 2" SCH. 80 PVC FOR PROPOSED PARKING LOT FUTURE CAMERAS (1) 2'' SCH. 80 PVC SPARE FOR FUTURE USE 18 x18"x18 QUAZITE PULL BOX AND WIRING BY DIV. IA CONTRACTOR (1) 2" CONDUIT FROM LIGHTING CONTACTOR INSIDE TANK TO PULL BOX BY DIV. I CONTRACTOR, WIRING BY DIV. IA CONTRACTOR \ • • • NK FLOODLIGHT CO D INSlf,LLEO BY DI • • .f • LIGHT FIXTURES, 1" SCH. 80 PVC CONDUITS AND WIRE FOR TANK LIGHTING (MIN. 24" COVER) BY • 'DIV. IA CONTRACTOR (1) 2" SCH. 80 PVC FOR PROPOSED PARKING LOT POLE LIGHTING (1) 2" SCH. 8D PVC FOR PROPOSED PARKING LOT FUTURE CAMERAS (1) 2" SCH. 80 PVC SPARE FOR FUTURE USE [: LIGHT POLE TO BE ENERGY , r E PULL TRACTOR, E : TRACTOR NNECTS ON UNISTRUT STAND (SEE RISER FOR MORE TOR SIDE TANK TO PULL BOX BY DIV. I RACTOR ,.,;,,+,,., l.ll [:...,;,;...;i,_111t '\,, ' -=--'-' ' -� PARKING LOT AND TANK LIGHTING SITE PLAN SCALE, 1" = 30' • REVISIONS 2/8/24 BID SET 0 2024 Mtrlwes!cm Engineers. Inc. 802 Wesl Broarlway Street P.O Bo� Z95 Loogoutec, J11di"na 47553 DATE JANUARY 2024 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK PROJECT NUMBER 2021058-00 6 6 OF 7 I Fll.£ NUMBER I 42694A Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2