GENERAL ELECTRICAL NOTES 1. 2. 3. 4. 5. 6. 7. ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. CONTRACTOR SHALL PROVIDE AND INSTALL NEMA 4X S.S. ENCLOSURE UTILIZING STAINLESS HARDWARE. ALUMINUM UNI-STRUT STAND PROVIDED AND INSTALLED BY DIV. I CONTRACTOR. ALL EXPOSED CONDUITS SHALL BE ALUMINUM, SCH. 80 PVC IF BURIED, UNLESS OTHERWISE NOTED. CONTRACTOR TO UTILIZE PVC COATED RIGID THROUGH CONCRETE BASES. ALL OUTDOOR ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL AND HAVE HASP AND STAPLE FOR PADLOCK UNLESS OTHERWISE NOTED. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, OTHER MATERIAL, AND INSTALLATION NEEDED FOR A COMPLETE SYSTEM UNLESS OTHERWISE NOTED. COORDINATE ALL ROUGH IN REQUIREMENTS w/ PARKING LOT CONTRACTOR DURING CONSTRUCTION. IT SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE SCOPE OF WORK BETWEEN ELECTRICIAN AND PARKING LOT SITE WORK PRIOR TO BID. IN GENERAL THE DIVISION IA SCOPE SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO PANEL "8'', PARKING LOT LIGHTING CONTACTOR, TANK LIGHTING CONTACTOR, CONDUIT, WIRE, LIGHTS, POLES AND CONCRETE BASES WITH ALL MISC. MATERIALS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. THE DIVISION I CONTRACTOR WILL HAVE THE ELECTRIC SERVICE AND RACK SET, SERVICE ENTRANCE RATED DISCONNECT, PANEL "A" INSIDE THE TANK AND ALL TANK RELATED SITE CONDUITS AND PULL BOXES. SQUARED TYPE N QOD 120/240V-10, 3W, 200A MCB P ANELBOARD "A" IN NEMA 1ENCLOSURE,COP PER BUSSING, IN SIDE TANK BYD IV ICON TR ACTOR 16,18 19,21 20 <' l�20A-2P l�20A-2P �20A-1P G) G) = :::POLES 1,2 0 0 ' 0 0 0 ' = :::POLES 3,4 ' G) ' PC 1--- LOCATE PHOTOCELL OUTSIDE TANK, ACCESSIBLE FOR MAINTENANCE. COORDINATE LOCATION AND SENSITIVITY w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION. PARTIAL POWER DISTRIBUTION ONE LINE DIAGRAM - PANEL "A" NOT TO SCALE PANEL 100 AMPERES Ml OMAIN CONNECTION l!�I srnIIr 8�C� LOCATION DIV. I CONTRACTOR TO COORDINATE AND INSTALL 120/240V 1¢-3W ELECTRICAL SERVICE BY DUKE ENERGY. DIV. I t-i' DIV. IA B 120/240 VOLTS 1 PHASE SlJRFACF MOUNTING 'WIRE KAIC CIRCUIT WIRE CU. ITEM FEED AMPS POLE POLE AMPS NO. SIZE BUS ,J_ SURGE ARRESTOR 6 60 2 A 1 20 3 B 1 20 5 FIXTURE 3&4 LIGHTS "R3� 12 20 1 A 1 20 7 SPARE 12 20 1 B 1 20 9 SPARE 12 20 1 A 1 20 11 SPARE 12 20 1 B 1 20 13 SPARE 12 20 1 A 1 20 15 SPARE 12 20 1 B 1 20 17 SPARE 12 20 1 A 1 20 19 SPARE 12 20 1 B 1 20 21 SPACE 12 20 1 A 1 20 23 SPACE 12 20 1 B 1 20 25 SPACE 12 20 1 A 1 20 27 SPACE 12 20 1 B 1 20 29 SPACE 12 20 1 A 1 20 V UNDERGROUND ELECTRIC SERVICE CONDUCTORS BY DUKE ENERGY. DIV. I CONTRACTOR TO PROVIDE AND INSTALL 2" SCH. 80 PVC CONDUIT W/ LONG SWEEP ELBOWS BETWEEN TRANSFORMER POLE AND METER POINT. PULL ROPE, TRENCH, COVER SEED AND STRAW BY CONTRACTOR. 200A DOUBLE GANG METER BASE PROVIDED AND INSTALLED BY DIV I CONTRACTOR, METERING, WIRING AND TERMINATIONS BY DUKE ENERGY I--- - 200A-2P SERVICE ENTRANCE RATED CIRCUIT BREAKER DISCONNECT IN ' NEMA 4X S.S. ENCLOSURE BY DIV. I CONTRACTOR +---- (3) #3 THWN (1) #6 CU. GND. 1" CONDUIT S.E.L. WIRE ITEM FEED SIZE 12 PHOTOCELL 12 FIXTURE 1 &2 LIGHTS HR3� 12 DUSK TO DAWN LIGHT 12 SPARE 12 SPARE 12 SPARE 12 SPARE 12 SPARE 12 SPARE 12 SPARE 12 SPACE 12 SPACE 12 SPACE 12 SPACE 12 SPACE CIRCUIT NO. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 SQUARED TYPE N Q 120/240V-10, 3W, 100A MLO P ANELBOARD "B" IN NEMA 1ENCLOSURE,COP PER BUSSING 1,3 2 4 5 \60A-2P J)-20A-1P �20A-2P l,20A-2P DIV. IA CONTRACTOR T0-----1 PROVIDE AND INSTALL NEMA 4X S.S. ENCLOSURE TO HOUSE LOAD CENTER, SURGE ARRESTOR AND PARKING LOT LIGHTING CONTACTOR 3----LEADS TO BE AS SHORT AND STRAIGHT AS POSSIBLE SA 0 G) ' SURGETRACK SURGE ARRESTOR· w/ SURGE COUNTER 120/240V-10 CAT.# TK-ST120-1 S240-B OR EQUAL LOCATE PHOTOCELL ---< PC ADJACENT TO SERVICE CABINET. COORDINATE SENSITIVITY w/ OWNER. G) ' = �POLE = =POLE 1,2 3,4 , 0' � 0 ' 6 20A-1P =POLES 5-8 POWER DISTRIBUTION ONE LINE DIAGRAM - PANEL "B" NOT TO SCALE KEY NOTES (D (2) #12 THWN (1) #12 CU. GND. 1" CONDUIT Q) (2) #1D THWN (1) #10 CU. GND. 1" CONDUIT G) TWO CONDUITS FROM CONTACTOR LOCATION INSIDE TANK TO PULL BOXES BY DIV. I CONTRACTOR. CONDUIT FROM PULL BOXES TO LIGHTS AS WELL AS REQUIRED WIRING IS BY DIV. IA CONTRACTOR. CONTRACTOR TO PROVIDE AND INSTALL 30A SQ.D CLASS 8903 TYPE LG ELECTRICALLY HELD 8 POLE NON-COMBINATION LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE AND HAND-OFF-AUTO SELECTOR SWITCH, AUTO OPERATION SHALL FUNCTION FROM THE PHOTOCELL. I REVISIONS 2/8/24 BID SET C 2024 Mirlweslem Engineers, Inc. 802 Wes! Bru..dw,1y Street P.O. Box 295 Loogoote.:. lndi31M 47553 DATE JANUARY 2024 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK PROJECT NUMBER 2021058-00 7 7 DF 7 Fll.E NUMBER I 42694 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2