Midwestern Engineers, Inc. Plan Preview

LEGEND 8 ® 0 © 0 0 (j) ® 0 @ @ @ (2) #12 THWN (1) #12 CU. GND. 1" CONDUIT DiMMAllLe llGHi $WITCH, NDRMALlY ON (�) 1m fHWN (1) #10 GU. CNll , 1" tCNOU1f 11' I� TH[ INT�Nt OF tHI� �ROjeCT iD l'Lif i1XISTIN� FIXTURi;:s #I � #6 ON fHt sAMc CIRCUIT M SHliWN. CONTRACTOR SHALL MAKE cONNECTiON WITH IRREVERSlilLE LONG CRIMP SPLICE. BUTT SPLICES SHALL BE CERTIFIED FOR COPPER ONLY, NOT ALUMINUM AND COPPER BOTH. HEAT SHRINK WITH SEALANT SHALL BE USED TO FINISH CONNECTION. IT IS THE CONTRACTORS RESPONSIBILITY TO PROVIDE AND INSTALL ADDITIONAL CONDUIT AND WIRE VIA PULL BOX #2 & #4 AS REQUIRED TO RECONNECT EXISTING LOAD TO PROPOSED DISTRIBUTION PANEL WITHOUT ADDITIONAL INSTRUCTION FROM THE ENGINEER OR COST TO THE OWNER. SEE PROPOSED ONE LINE DIAGRAM FOR MORE INFORMATION. FIELD VERIFY EXACT LOCATION WITH OWNER AND ENGINEER DURING CONSTRUCTION PRIOR TO INSTALLATION. MAX LOAD 192DW (3) #8 THWN (1) #10 CU. GND. 1" CONDUIT MIDWEST ELECTRIC PRODUCTS, OUTDOOR RATED POWER OUTLET MOUNTED ADJACENT TO ELECTRICAL SERVICE PANEL, 50A (14-50R), MODEL #U054P. MAX LOAD 9600W MIDWEST ELECTRIC PRODUCTS, METALLIC RV POWER CENTER, NEMA 3R GALVANIZED WELDED STEEL CONSTRUCTION WITH PAD LOCK, 1 DOA, 120/240V, MODEL #U075CTLO10, UL LISTED. THE CONTRACTOR SHALL MOUNT TO SMALL CONCRETE PAD WITH COMPLETE POST ASSEMBLY PER NEC AND MANUFACTURER'S INSTALLATION RECOMMENDATIONS. HOMERUN EACH PEDESTAL ON DEDICATED CIRCUIT, DO NOT DAISY CHAIN. SEE FIGURE #1 FOR ADDITIONAL INFORMATION. (3) #3 THWN (1) #8 CU. GND. 2" CONDUIT MIDWEST ELECTRIC PRODUCTS, METALLIC RV POWER CENTER, NEMA 3R GALVANIZED WELDED STEEL CONSTRUCTION WITH PAD LOCK, 100A. 120V, MODEL #U131CTL010, UL LISTED. THE CONTRACTOR SHALL MOUNT TO SMALL CONCRETE PAD WITH COMPLETE POST ASSEMBLY PER NEC AND MANUFACTURER'S INSTALLATION RECOMMENDATIONS. HOMERUN EACH PEDESTAL ON DEDICATED CIRCUIT, DO NOT DAISY CHAIN. SEE FIGURE #2 FOR ADDITIONAL INFORMATION. (2) #3 THWN (I) #8 CU. GND. 2" CONDUIT PANEL A ------<2CUP!J.0AMPERES 120/?40VOLTS I "?WIRE ___JM111C.i,8 MAIN CONNECTION ___....1 1 PHASE --------S�E�RY�IC�f�G� AB� l �NET��RAwG=KLOCATION S I IREAGF MOUNTING BY DUKE E j ERGY c --i--- -120/240V-1¢ FLUSH MOUNT PEDESTAL AT CORNER OF 1 1------ CHURCH ST. ANO HWY 231 BY DUKE ENERGY. CONTACT ADAM THORNE AT (812) 318-3248 FOR MORE INFORMATION. BY CONTRACTOR CONTRACTOR TO PROVIDE AND : � INSiALL 2" SCH. 40 PVC CONDUIT, LONG SWEEP ELBOWS AND PULL ROPE WITH MINIMUM 30" COV�R. WIRING AND frnMINAflONS BY DUK[ i;:NcRGY M ( 3) # 3/o THWN-�-�y 2" CONDUIT ,-� CONTRACTOR iO PROVIDE & INSTALl iooA RINGLESS M.E.G, APPROVW MCTER BASE, MCTERING 8Y DUKE ENERGY. r STAINLrss STEEl ENCLOSURE PROVIDED BY CITY, INSTALLED BY CONTRACTOR -------- -PROVIDE AS BUILi PANEL SCHEDULE AND MARKUPS io OWNER/ENGINEER AT COMPLETION OF PROJECT �------ CIRCUITI NO. [ ITEM FEED 1 PHOTOCELL CONTROL 3 EXISTING LIGHTS 1-6 5 PARK LIGHT FIXTURES 11 14 7 PAVILION RECEPTACLES � RV PEDESTAL 1 11 i--.1l.. RV PEDESTAL 3 15 17 PAVILION POWER PEDESTAL 19 SPARE 21 SPACE 23 SPACE 25 SPACE 27 SPACE 29 SPACE KAIC S.E.L. WIRE AMPS POLE CU. WIRE SIZE BU S POLE AMP S SIZE 12 12 12 12 3 3 3 12 20 1 20 1 20 1 20 1 100 2 100 2 100 1 20 1 A 20 B 20 A 20 B 2 50 A B 2 100 A 8 2 100 A 8 20 A 8 A B A LEGEND ---- NEW CONDUIT, WIRING, AND EQUIPMENT - cXISTING CONDUIT, WIRING, AND EQUIPM[Nf 12 12 12 8 3 3 12 ITEM FEED CIRCUIT NO. PAVILION LIGHTS 2 PARK LIGHT FIXTURES 7 10 4 SERVICE PANEL CONY. RECEPTACLE 6 OUTDOOR 240V CONY. RECEPTACLE ..._§_ 10 RV PEDESTAL 2 ,__11-14 RV PEDESTAL 4 i-1§.. 18 SPARE 20 SPACE 22 SPACE 24 SPACE 26 SPACE 28 SPACE 30 SQUARED TYPE NDOD SERVICE ENTRANCE RATED 120/240V 10-3W 30 CKT PANELBOARD "A" IN NEMA 1 ENCLOSURE, COPPER BUSSING AND INTEGRAL SPD 200A-2P ---------1 I I I I ... - PROVIDE ANO INSTALL (1) ---,,__ c>.++ I_ ) �20A-1P 2 3 4 '>20A-1P �20A-1P "). 20A-1P 5 6 7 8, 10 9,11 12,14 13,15 16,18 17 '>20A-1P �20A-1P '}20A-1P "). 50A-2P '•100A-2P '>100A-2P '>100A-2P �100A-2P 0 }100A-1P #4 BARE cu. GND. IN "-- ' I ISPD J'."¢ ALUMINUM L-- -===-----+----+------------+----------J-----l------+----+-----+-------Jf-------+------+-----1--- ----- EXOTHERMICALLY WELDED � TO Y."•x10· cu. CLAD I GND. ROD (TYP. OF 3 ON 1 o· LINEAR SPACING) I SQUARE D LG30 V02 3-POLE---f-- 1 _ _ _ _ __ _ LIGHTING CONTACTOR IN NEMA I 1 ENCLOSURE w/ CONTROL CIRCUIT FUSE FORM F. PROVIDE ONE SPST SWITCH FOR PHOTOCELL BYPASS w/ I INSTALL EQUIPMENT ON "' I, v · ,._ ' 8 CD ' =:=POLE 1 =*= POLE 2 ' 8 8 ' 8 I, 8 J,. ==POLE 4 ' w u wz�w u- "' z�w 0..>w - z u Cc Ow "u O' I I I I I PHENOLIC TAG THAT READS "PHOTOCELL BYPASS" I NEW BACKPLANE, MINIMIZE ENCLOSURE PENETRATIONS ----- -- -- -- --� --�-- --� - -f-, _____J LOCATE ADJACENT TO SERVICE CABINET. COORDINATE SENSITIVITY w/ OWNER. TIE SINGLE PHOTO CELL TO CONTROL LIGHT FIXTURE CONTACTOR. PC 8 ' "A" I, 8 ' "A" 8 "A" NEW PULL BOX #1 BY CONTRACTOR ON EAST CORNER OF CHURCH ST. AND HWY 231 (TYPE "A") 0 - +,(;! ,-- { 8{ , - # 3� #2)r� { { #4)--\ PAVILION LIGHTS EXISTING LIGHTS 0 PULL BOX #4 1 I (TYPE "B") '--,--J #10 #B I, ' �0 8 ' ' '). ' ''), # 9 .8 8 1' , \. , PROPOSED PARK LIGHTS #7 0 0 PULL BOX 5 1,--J---, # G): #13 8 #11 (TYPE "B'') ' 8 ./ . 1",, ' 8 ./ , PROPOSED PARK LIGHTS #14 #12 ,n 0 WP GFI CONVENIENCE OUTLETS AT PAVILION (TYP. OF 4) ELECTRICAL ONE LINE DIAGRAM NOT TO SCALE 8 7 OUTDOOR 240V-1¢ CONVENIENCE OUTLET I @ I PULL BOX #4 I (TYPE "B"\ @ PU / LL BOX _#2 I TYPE �B�l @ 0 RV PEDESTAL #1 RV PEDESTAL #2 . ' ' I PULL BOX #5 I (TYPE "B' ' ) @ @ I PULL BOX #3 I (TYPE "B") @ 101 RV PEDESTAL #3 @ 0 RV PEDESTAL #4 ' @ @ PAVILION POWER PEDESTAL 6/13/2024 BID SET Cl 2024 Midwe.!lt'mEnginctrs. !nc. 802 We.,\ Broadway Street P.O. Box 295 Loogool��- Indian" 47553 DATE JUNE 2024 DESIGN AFB DRAWN CNM a.c. CHECK WAE PROJECT NUMBER 2022115-00 20 20 OF 20 I Fll£ NUMBER I 43458 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2