Midwestern Engineers, Inc. Plan Preview
a s 0 0 w ~ w ,n ~ ' 0 0 5' 0 L 0 ,. 0 ::, 0 0 "' n PROPOSED 4" SCH. 80 PVC ~ CONDUIT, LONG SWEEP ELBOWS -,,-......_ PROPOSED 120/208V-3¢, 4W TO BE PROVIDED & INSTALLED BY NIPSCO AND PULL STRING BY CONTRACTOR. WIRING AND TERMINATIONS BY NIPSCO. rr-:::::::-J---200A SELF CONTAINED (4) #2 THWN ---'1". 2" ALUMINUM )-100A-3P METERBASE BY CONTRACTOR, MITTRING BY NIPSCO 1OOA-3P SERVICE ENTRANCE RATED CIRCUIT BREAKER DISCONNECT IN NEMA 4X S.S. ENCLOSURE, SQ.D OR ENGINEER APPROVED EQUAL ,t,,------(4) #2 THWN (1) #8 CU. GND. 2" ALUMINUM #8 BARE CU. GND. IN CONDUIT J EXOTHERMICALLY WELDED TO (3) K'¢x1 o· cu. CLAD GND. RODS 60A-3P 60A-3P PROPOSED PUMP CONTROL PANEL AND SCADA RTU PROVIDED BY THE OWNERS ON 1O' TRIANGULAR SPACING ,__ __ ,.c:::- - :;:i.._ HANDLETIE EXISTING SCADA SYSTEM INTEGRATOR AND INSTALLED BY THE CONTRACTOR 0 2 3 4 5 6 7 RUSSELLSTOLL J-LINE INTERCONNECTION SYSTEM, THOMAS & BETTS CAT.# JPS1044FR, 1OOA, 4W, 4P WEATHERPROOF (4) #6 THWN (1) #10 CU. GND. )-3oA-3P }-30A-3P )-sA-1P )-sA-1P )-20A-1P }-3A-1P }-3A-1P J_ J_ i l ~ @] @] (3) #12 THWN (1) #12 CU. GND. 1~" CONDUIT CONTINUOUS HINGED NEMA 4X S.S. VENTED JUNCTION BOX SEE DETAIL THIS SHT. HEATER RECEPTACLE SCADA '-r---i=::'_-PUMP CABLES PROVIDED BY 208V-3¢ 208V-3¢ 11 FLA 11 FLA PUMP SUPPLIER, INSTALLED BY CONTRACTOR PROPOSED ONE LINE DIAGRAM NOT TO SCALE GENERAL SCADA SYSTEM NOTES POWER SUPPLY POWER SUPPLY 8 )-20A-1 P WP GFI 1. THE CONTRACTOR SHALL UTILIZE THE OWNERS EXISTING SCADA SYSTEM INTEGRATOR FOR PROVIDING THE PROPOSED PUMP CONTROL PANEL, JUNCTION BOX, FLOATS, GENERATOR RECEPTACLE AND CONTROL DEVICES AS NOTED. CONTACT NATHEN BURKHART AT 317-718-1800 FOR SCOPE AND PRICING PRIOR TO BID. SEE ELECTRICAL SPECIFICATIONS FOR MORE INFORMATION. 2. THE PROPOSED PUMP CONTROL PANEL SHALL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO, THE FOLLOWING: A. ALLEN BRADELY PLC B. ANTENNA C. ABB NEMA RATED MOTOR STARTERS w/ OVERLOADS D. DIGITAL WETWELL LEVEL DISPLAY E. CIRCUIT BREAKERS AS REQUIRED F. PHASE MONITOR G. SURGE PROTECTION DEVICE H. GENERATOR PLUG I. ALARM LIGHT AND HORN WITH SILENCE, PUSH-TO-TEST AND ENABLE/DISABLE SWITCHES J. NEMA 4X S.S. ENCLOSURE w/ LIGHT AND HEATER K. UNINTERRUPTIBLE POWER SUPPLY L LIGHT SWITCH ON SWING OUT DOOR M. WEATHERPROOF GFI REC MOUNTED THROUGH ENCLOSURE 3. ALL STARTUP AND PROGRAMMING SERVICES AT THE LIFT STATION AND MASTER CONTROL PANEL SHALL BE INCLUDED AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. 4. INPUTS/OUTPUTS: DIGITAL INPUTS: PUMP #1 RUN STATUS (ON/OFF) PUMP #1 ALARM (OVERLOAD) PUMP #1 ALARM (SEAL LEAK) PUMP #1 ALARM (OVERTEMP) PUMP #2 RUN STATUS (ON/OFF) PUMP #2 ALARM (OVERLOAD) PUMP #2 ALARM (SEAL LEAK) PUMP #2 ALARM (OVERTEMP) FLOAT - OFF FLOAT - LEAD ON FLOAT - LAG ON FLOAT - HIGH LEVEL STATION POWER LOSS STATION PHASE LOSS COMMUNICATION FAILURE EXISTING POWER POLE TO BE REPLACED BY NIPSCO DIGITAL OUTPUTS: ANALOG INPUTS: ANALOG OUTPUTS: PUMP #1 CALL PUMP #2 CALL ALARM LIGHT ON ALARM HORN ON WETWELL LEVEL WETWELL LEVEL DISPLAY PROPOSED ELECTRICAL EQUIPMENT ON UNISTRUT STAND r NEW LIFT STATION FIELD VERIFY EXACT ROUTE OF UNDERGROUND ELECTRIC SERVICE DURING CONSTRUCTION NEW 6" FORCE MAIN lli NEW 6" CONCRETE j PAD AROUND VALVE VAULT AND WET WELL ,(;~\\ '~ t EXISTING STRUCTURE TO f- BE REMOVED \\ ~~ J BE - BE R/W ~-V.=-BF==~i"~– -----~~---...;~_B,;E"tr- BE___. E-OHE-OHE ___-DHE-OHE-OHE-o ---<f_- W·--- ---w HE-OHE-OHE-OHE-OHE- OHE-OHE-OHE- ~fYmoufh - Gosh --- -----£P -~ail - EXISTING 12" DT WATER MAIN ---w___ ------- w --- 0-:-~~-o s-cALS_E T_A_T_I_O_N_E_LE_C_T_R_IC_A_L_S_I_T_E_P_L_A_N_ LEGEND CD THE CONTRACTOR SHALL FIELD VERIFY THE OWNERS EXISTING GENERATOR PLUG CONFIGURATION FOR COMPATIBILITY PRIOR TO ORDERING. ONCE COMPLETED, CONNECT GENERATOR AND RUN STATION TO CHECK ROTATION. GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. FLOAT WIRING INTERIOR VIEW MOTOR SAFETY WIRING LEVEL XMTR WIRING 2. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL 3. ALL CONDUIT SHALL BE SCHEDULE 80 PVC IF BURIED, ALUMINUM IF EXPOSED UNLESS OTHERWISE NOTED. GROUT AROUND ALL PENETRATIONS INTO CONCRETE STRUCTURES. MOTOR WIRING---+1111 4. ALL ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL UNLESS OTHERWISE NOTED. ALL ENCLOSURES SHALL HAVE A HASP AND STAPLE FOR PADLOCK. 5. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, OTHER MATERIAL, AND INSTALLATION FOR A COMPLETE AND FUNCTIONAL SYSTEM. 6. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. SEED AND STRAW OR STONE ALL SURFACES TO PRE-DISTURBED CONDITION. 7. CONTRACTOR TO REMOVE UNUSED ELECTRICAL EQUIPMENT AS A RESULT OF THE PROJECT. OWNER RESERVES THE RIGHT TO ANY REMOVED EQUIPMENT. ANY UNWANTED EQUIPMENT, MATERIAL, CONDUCTORS, ETC. SHALL BE DISPOSED OF BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 8. ENSURE 5' MIN. BETWEEN WETWELL VENT AND JUNCTION BOX. LOCATE NEW JUNCTION BOX AT A MIN. OF 18"' ABOVE TOP OF WELL. 9. CONTRACTOR TO VERIFY CONDUIT SIZE BETWEEN JUNCTION BOX AND PUMPS IN WET WELL TO ACCEPT PUMP POWER CABLES (PER NEC), TYPICALLY USE LONG SWEEP ELBOWS. 1 0. ALL UTILITY FEES WILL BE PAID BY OWNER IN FULL PRIOR TO CONSTRUCTION. CONTRACTOR TO CONTACT RICHIE MORGAN w/ NIPSCO AT 574-935-8194 A MIN. OF FOUR WEEKS PRIOR TO COORDINATE NEW SERVICE INSTALLATION. NOTIFY OWNER OF ALL REQUIRED OUTAGES A MIN. OF 48 HOURS IN ADVANCE. JUNCTION BOX --t--K– STAINLESS STEEL 16 37 FRONT 4.39-~ CABLE ACCESS --i~~C::':~ ALUMINUM CLASS I, DIV. I RATE CABLE GROMMET/GLAND AND STAINLESS STRAIN RELIEF (TYP.) CONTINUOUS PIANO HINGE EXTERIOR VIEWS RIGHT SIDE LEFT SIDE 7.61--- FACE MOUNT PADLOCKABLE HASP 11. POWER FOR TEMPORARY BYPASS PUMPING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. JUNCTION BOX DETAIL NOT TO SCALE 12. FIELD LOCATE JUNCTION BOX AND WETWELL VENT w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION. OVERHEAD PRIMARY, TRANSFORMERS & POLE BY NIPSCO \ I '°"' 1~" RIGID ALUMINUM CONDUIT LED DOWN LIGHT-~~ ON WP SWITCH I "" ·))---NEW ANTENNA, VERIFY DIRECTION PRIOR .,,, , 1" ALUMINUM CONDUIT-~-+H TO INSTALLATION w/ INTEGRATOR NEW POLE & RISER BY NIPSCO w/ TESCO LMR 400 CABLE OR EQUAL 11--~--BOND ANTENNA TO GROUNDING ELECTRODE CONDUCTOR - - ALUMINUM UNI-STRUT-~~=;5:~l:i;=~~~~::r[j~~~B:::~31-~- VERTICAL, HORIZONTAL ~ ill'!' AND SIDE SUPPORTS 200A METER BASE BY---+-- ~ STATION AS REQUIRED TO CONTRACTOR, PUIIP SUPPORT EQUIPMENT METERING BY NIPSCO I= e:: CONTROL PANEL 1OOA-3P SERVICE ENTRANCE ----,r-++t-++-++--1 RATED CIRCUIT BREAKER n-~-.' DISCONNECT IN NEMA 4X S.S. ENCLOSURE, SQ.D OR ENGINEER APPROVED EQUAL NEMA 4X f;f. STEEL ,,,.-- GENERATOR 0,,/ RECEPTACLE .._D r - >- CONTINUOUS HINGED ::-\ NEMA 4X S.S. VENTED \ JUNCTION BOX SEE \ DETAIL THIS SHT. / RADAR LEVEL TRANSMITTER / w/ BLUETOOTH UNDERGROUND SECONDARY.– SEE ONE LINE DIAGRAM THIS SHEET LENGTH OF STAND - x 4' DEEP - ~ V CLASS I, DIV. 1/11 CONDUIT SEALING FITTING (TYP.) ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) ~" STAINLESS STEEL ALL-THREADS IN CONCRETE '·,, ./- 4"X4"x.l'4" ALUM. ANGLE ~" ALUM. BASE PLATE BASE DETAIL NOT TO SCALE .. . . . . . ' A • . • • ;\ MIN. 5' SEPARATION /I'-. --~--r-t---1, ('\..J - \\ 4:_,. . . . . , .. '-~ /j " . .. HIGH LEVEL LAG ON LEAD ON OFF • • ·. ' .. ··~"'~-.·ii,···~ . ·-t ~. ·. (2) 3HP 208V-3¢ 11 FLA ' • . A I• • . ' . 4. ; • A 4 •· ' PROPOSED LIFT STATION ELECTRICAL RISER NOT TO SCALE ' , . ;r . ....r , r~ ,m, .. SLOPE CONCRETE & GRADE - AWAY FROM STATION (TYP.) .. .. . ,:::::-,. _) \... , ,,_- . .. ,1 . 1• .;: . ·."'li . • .. • ' -. . . ./ : . . -- ·, ... , ·r· . . 1 ', ,' :, • u g ';i d ~ u ~ " ·~ 1-4 N ' ~ £ ' ~ ' V ~ " "' -~ - 0 '" ' ~ 00 ,.,~g I°' -~oo "'l ~ Sz 'i1 a CJ :/)-~ :§ ~,.rS'l ~ ~ CJ ~~E m - go d 5 ~ii i " • ~ .§ a. (.J j a ·a ...... • "' • . er; " J:i • N u ·E 0 C V d 00 oc ~ • '';' f~~ ,_(', ~ N ,..:, oc -~ Q -~ ] ~ ~ ;E ' ' CJ ~ • ' ;..,I ' C, • 00 ' 00 -~ ~ N ~- CJ ..... -.!" ·..o ~ ~z~ t ~ --, ~ ~ ~ .'!}.~;;: j = "-0 c!. ' ~ " o.- ~ .,, 8 ~: = 0 • - ' "' C ·~ Q. ~ " • ..-4 ~] " 8 ::E ~ I- 0 w -, 0 o:'. a... I C) z z I- - <( ::::> < U) z U) ~ 0 < 0 0 w ~ 2 o:'. 0 >- >" 0 o:'. >- o:'. ...J 2 _J 0 0 a.. ::, <( LL 0 LL (.) z 0 LL ...J ...J z z 0 < I w <( UJ I- >- Cl'. z z < I- :a w 0 0 I- () ;:: U) I- LL _J REVISIONS 3/4/2020 BID SET @2020 Midwestern Enginc-crs. Inc 802 Wc~t Brnadv,;ay Street P.O. Box 295 Loogootee, Indiana 47553 DATE MARCH 2020 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK M.M.S. PROJECT NUMBER 2019102-00 7 7 OF 7 I FlLE NUMBER • 39837 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2