0 �· w 0 m' > = 0 �· I t' i'/ Ii-: �· N• NO 81!2 �g � �� 2� •w 0� � -· .2� "o - >0 � 02 8 ;;1 .. �< "' o9 � i, N 55 , . <• GENERAL ELECTRICAL NOTES (APPLICABLE TD ENTIRE PROJECT) NO MORE THAN SIX CURRENT CARRYING CONDUCTORS (INCLUDING NEUTRAL CONDUCTORS) IN ANY ONE CONDUIT CARRYING 20-AMP LIGHTING OR RECEPTACLE LOADS WITHOUT DERATING IN ACCORDANCE WITH NEC ARTICLE 310. ALL OTHER CIRCUITS SHALL BE IN A DEDICATED CONDUIT, PROVIDE GROUND CONDUCTOR IN ALL CONDUITS. SIZE PER NATIONAL ELECTRIC CODE. ALL WIRING SHALL COMPLY WITH THE LATEST EDITION OF THE INDIANA ELECTRIC CODE AND COMPLY WITH COUNlY AND/OR LOCAL JURISDICTION HAVING AUTHORllY IN THAT AREA. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR THE EXACT LOCATION AND ROUGH-IN REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT AND PIPING BEFORE ROUGH-IN. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND OWNER BEFORE WIRING IS TO BEGIN TD VERIFY ALL OTHER CONDITIONS SO THAT WIRING WILL NOT INTERFERE WITH THE OTHER TRADES. ALL ELECTRICAL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ENTIRE ELECTRICAL SYSTEM SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. ALL MATERIALS USED IN THE WORK SHALL BE APPROVED BY THE UNDERWRITER'S LABORATORIES, INC, AND SHALL BEAR THEIR LABEL THE CONTRACTOR SHALL, AT HIS/HER OWN EXPENSE, OBTAIN ALL PERMITS, INSPECTIONS, CERTIFICATES, AND LICENSE REQUIRED BY LAW FOR THE EXECUTION OF WORK TO BE PERFORMED. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT AS INDICATED ON THE DRAWINGS. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND OF FIRST CLASS CONSTRUCTION, AND SHALL BE THE PRODUCT OF AN ESTABLISHED AND REPUTABLE MANUFACTURER, AND SHALL BE DESIGNED TD PERFORM THE SERVICE REQUIRED. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL HARDWARE, LAMPS, ACCESSORIES, ETC AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. MULTI-WIRE (SHARED NEUTRAL CIRCUITS) SHALL NOT BE USED. PROVIDE A NEUTRAL CONDUCTOR FOR EACH LINE-TD-NEUTRAL CIRCUIT. ALL POWER AND CONTROL CIRCUIT WIRING USED SHALL BE "fHHN" OR "THWN" COPPER UNLESS OTHERWISE SPECIFIED OR REQUIRED BY CODE. PER NEC 310,10, ALL WIRING SHALL BE SIZED TO COORDINATE WITH TEMPERATURE RATINGS OF TERMINATIONS LISTED WIRE SIZES ON PANELBOARD SCHEDULES ARE MINIMUM SIZES. SIZE WIRE TD MEET TEMPERATURE AND VOLTAGE DROP REQUIREMENTS PROVIDE A PULL ROPE IN ALL SPARE CONDUITS. PROVIDE ID TAG AT EACH END OF PULL ROPE IDENTIFYING LOCATION OF OPPOSITE END, ELECTRICAL SYMBOLS ARE NOT SHOWN TD SCALE. WHEN DEVICES ARE SHOWN ADJACENT, INSTALL IN ADJACENT BOXES. COMPLY WITH BOX FILL REQUIREMENTS OF NEC ARTICLE 314. PROVIDE CONDUIT EXPANSION FITTINGS WHERE CROSSING BUILDING EXPANSION JOINTS. ALL SAFETY SWITCHES SHALL BE "HEAVY DUlY" OWNER RESERVES FIRST RIGHTS TD ANY REMOVED EQUIPMENT AND MATERIALS. ALL UNWANTED EQUIPMENT AND MATERIALS SHALL BE DISCARDED BY CONTRACTOR PER LOCAL, STATE AND FEDERAL REGULATIONS AT NO ADDITIONAL COST TO THE OWNER. THE GENERAL CONTRACTOR SHALL COORDINATE SCOPE OF SUPPLY, INSTALLATION AND TERMINATION OF ALL CONTROL DEVICES BETWEEN INTEGRATOR AND ELECTRICIAN AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM PRIOR TO BID. THE CONTRACTOR SHALL COORDINATE ALL POWER AND CONTROL CONDUIT, WIRE AND CONNECTION WITH ALL RELATED TRADES DURING CONSTRUCTION PRIOR TD INSTALLATION. THIS SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TD ELECTRICAL, CONTROLS, HVAC AND PLUMBING. VERIFY ALL WORKING CLEARANCES FOR BUILDING, TRANSFORMER, STANDBY POWER GENERATION AND PROCESS EQUIPMENT AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. ALL UTILllY RELATED FEES WILL BE PAID FOR BY THE OWNER DURING CONSTRUCTION. IT SHALL BE THE CONTRACTORS RESPONSIBILllY TD AID THE OWNER IN APPLYING FOR AND SUCCESSFULLY COORDINATING/SCHEDULING THE WORK TO BE COMPLETED. IT SHALL BE THE CONTRACTORS RESPONSIBILllY TD QUANTIFY AND SIZE ALL NECESSARY PULL BOXES PER NATIONAL ELECTRIC CODE, SOME MAY NOT BE SHOWN FOR CLARllY. THE BOXES SHALL BE EQUAL TO QUAZITE POLYMER CONCRETE, 24" DEEP WITH SOLID BOTTOM INSTALLED ON COMPACTED STONE BASE; DRILL (2) WEEP HOLES FOR DRAINAGE. LIDS SHALL BE CASKETED AND BOLTED DOWN WITH LOGO THAT READS "ELECTRICAL". LIDS TD BE TRAFFIC RATED FOR TIER 15 VERTICAL LOADING, NON-DELIBERATE. J '-.__ '-.__ '-.__ • '- . __ '-.__ > '- . __ ,_,,,,-- cc::_,,, ---..__ -_ I- -_ WWTP ELECTRICAL ROOM (480V-3¢) '- - -, <, / (3) 3" CONDUITS TD MDPC IN "- ...� t ----- ,,-,---- '-.__ ' -- ___ ... \ "-...... --- -- � (. � ---......... t---- - t '-.__ -_, CLARIFIER DRIVE No. 1 ½ HP, 480V-3¢, 1.6 FLA FIBER TO WWTP SCADA PANEL CLARIFIER SCADA PANEL LIFT STATION RAS/WAS PUMPS #1, #2 & #3 15HP, 480V-3¢, 21 FLA (EA.) _y"!J vLARIFIER DRIVE No. 2 ½ HP, 480V-3¢, 1.6 FLA --, , -_ ' OXIDATION DITCH MOTOR No. 15 HP, 480V-3<, 21 FLA '- . __ '-.__ '-.__ '-.__ '-.__ OXIDATION DITCH MOTORS No 2 3 l / . I / I NOTE, CONDUIT TRENCHES TD BE 24" DEEP w/ ELECTRICAL WARNING TAPE @ 12" DEEP 30 HP, 480V-3¢, 40 FLA (EA) '- . __ NEW OXIDATION DITCH PROPOSED PULL BOX "A" OXIDATION DITCH MOTOR No. 15 HP, 480V-3o, 21 FLA c( ✓ (3) 3" SPARE CONDUITS TO CHEMICAL �c FEED BUILDING ELECTRICAL ROOM (2) 3" CONDUITS-4,� ,· �_r -- - -- , ,--,--/ (3) 3" CONDUITS FOR MDPB 480V-30 TO MOPB '"'--: ,--,--/ (3) 3" CONDUITS FOR MDPC 480V-30 1-,--E PB E--E---( 3" SPARE CONDUIT (3) 3" CONDUITS�/-,--, DIV. I ,--,--/ 3" SPARE CONDUIT FOR MDPC 480V-3¢ 1-,--, ,--,--/ 2" CONDUIT FOR SCADA FIBER AND DATA/INTERNET t:=:h: ---,_ ____ _J ,--,--1 4" SPARE CONDUIT (DEAD ENDED IN PULL BOX) (1) 2" CONDUIT FOR SCADAJ l(1) 2" CONDUIT FOR SCADA NOTE, PULL BOX, PULL ROPES AND CONDUITS TO FIBER AND DATA/INTERNET FIBER AND DATA/INTERNET TO HEADWORKS BUILDING PROVIDED AND INSTALLED BY TO CHEMICAL FEED BUILDING CLARIFIER SCADA BUILDING DIV. I CONTRACTOR. ALL REQUIRED WIRING AND FURTHER CONDUITS TD BE PROVIDED AND INSTALLED BY DIV. II CONTRACTOR. SEE PROPOSED ONE LINE DIAGRAM FOR MORE INFORMATION, DIV. I PULL BOX DETAIL NOT TD SCALE � � -::::::- -::::::- -::::::- -::::::- -::::::- -::::::- ;/ NOTE: CONTRACTOR SHALL SEPARATE ALL POWER AND CONTROL REGARDLESS OF VOLTAGE AND PHASE; SEPARATE ALL FIBER, ETHERNET, DIGITAL AND ANALOG, MINIMUM CONDUIT SIZE 1". WASTEWATER TREATMENT PLANT - ELECTRICAL SITE PLAN EAST SCALE, 1" - 20' • u :: - REVISIONS 9/'/2021 BID SET © 2021 l>!idwc,tc·m Eng.inc�r,. lnc. S02 We,, IJniadwny St...,ct 1'.0. Bo.� 29.'i Lvo�uotc•c. !ndian:, -!7553 DATE SEPT. 2021 DESIGN A.F.B. DRAWN C.N.M. O.C. CHECK R.D.W. PROJECT NUt.1.BER 2015078-01 E1 02 100 OF 11 4 FILE NUMBER 41972 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2