Midwestern Engineers, Inc. Plan Preview

8 OXIDATION DITCH PULL BOX "B" 2-E-- < (1) 1'' SPARE TO PULL BOX "C" :;.-,--, (1) 2" SPARE TO PULL BOX "8'' :; . -,--, AND "c" OXIDATION DITCH PULL BOX "A" :C- ,__, (1) 2" SPARE TO PULL BOX "A" :C- ,-- , PB , --E ------< VF □ INTERLOCK WIRING , --<----i; 480V-30 BELDEN CABLES (ox DITCH) <-<----i: 480V-30 BELDEN CABLES (RAS/WAS) ,- -E-------;:: 120V-1¢ POWER ,--E-------( DIGITAL CONTROL ,__ E ANALOG CONTROL ,-- E------( 480V-3¢ ,--,----i; (1) 3" SPARE STUBBED UP INSIDE <--<----i: (1) 2" SPARE STUBBED UP INSIDE NOTE; SOME CONDUITS NOT SHOWN FOR CLARITY, SIZES VARY. TYPICALLY USE LONG SWEEP ELBOWS . SEPARATE POWER AND CONTROL; ANALOG, DIGITAL, ETHERNET. FIBER TO OPPOSITE SIDES OF PULL BOXES AND TRENCHES (TYPICAL) PULL BOX "D" DETAIL ENLARGED FOR CLARITY Type A B C D E F G H I LIGHT FIXTURE SCHEDULE Basis of Design or Approved Equal COLUMBIA LIGHTING - CFP24-5540 COLUMBIA LIGHTING - LXEM4-40HL-RFA-EU-SSL DUAL LITE - CATALOG No. EVCURW LED COMBINATION EXIT/EMERGENCY LIGHT HUBBELL LIGHTING - WGH2-LSCS-4K-U-L w/ PHOTOCELL HUBBELL LIGHTING - DDL-9L1 w/ PHOTOCELL HUBBELL LIGHTING - LNC3-24L-4K-U-DBT-PCU PRESCOLITE LIGHTING - LBSES-4RD-CS9-WH KIM LIGHTING - UR20-56L-75-4K7-5W-UNV-PT23-LGT-7PR-TL HUBBELL LIGHTING - FML-20L-52-4K-7-W-U-K Mounting LAY-IN SURFACE SURFACE SURFACE MAST ARM SURFACE SURFACE POLE KNUCKLE Lamps sow LED 47W LED 1.65W LED 60W LED 39W LED 60W LED 9.9W LED 75W LED 52W LED NOTE; CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS, BRACKETS, CABLES, PHOTOCELLS, ETC. FOR FULLY FUNCTIONAL SYSTEM. DATA AND TEL-COM NOTES PLENUM RATED CAT6 CABLE BLUE (DATA), YELLOW (PHONE). COVER PLATES TO MATCH SWITCHES AND OUTLET COVERS. SINGLE GANG BOX w/ ¾" CONDUIT IN THE WALL AND TURNED ABOVE THE DROP CEILING ROOM TERMINATIONS TO BE BLUE (DATA) AND YELLOW (PHONE) CAT 6 KEY STONES FOR TERMINATIONS OF SIMILARLY COLORED CABLES. COVER PLATE TO MATCH SWITCH AND OUTLET COVERS. CONTRACTOR TO TERMINATE, LABEL AND TEST ALL DROPS. LEGRAND PART No CJ21HW OR EQUAL TO BE USED AS CABLE MANAGEMENT ABOVE DROP CEILING. TRIPP LITE PART No. SR4 POST OR EQUAL SWITCH CABINET TO BE INSTALLED IN MECHANICAL ROOM . TRIPP LITE PART No. N252-P24 OR EQUAL TO BE INSTALLED IN SWITCH CABINET FOR NETWORK AND PHONE TERMINATIONS. CONTRACTOR SHALL PROVIDE ALL PATCH PANELS, PATCH CABLING, SWITCHES AND ASSOCIATED HARDWARE FOR A TURN-KEY DATA NETWORK. ABOVE SHELF (TYP. OF 2) PB "D" CONTRACTOR TO PROVIDE AND INSTALL 24"D QUAZITE PULL BOX, SIZE PER NEC. COORDINATE LOCATION w/ OWNER AND ENGINEER DURING CONSTRUCTION PRIOR TO INSTALLATION, SEE DETAIL THIS SHEET FOR ENLARGED PULL BOX INFORMATION. / 1 YELLOW ------+f•f<;I 1 BLUE SINGLE GANG BOX ¾" CONDUIT CU-1 / ' 8-6 0 1 OFFICE □ B-6 WH-1 8-6 I I / / 8-19 " ... 8-5 I I / T7 8-24 87� -""'1-l--; - ' L--- 1 YELLOW OFFICE / 1 BLUE / / SINGLE GANG BOX ¾" CONDUIT 1 : 0UNTER FOR OVEN ) f"B-36 1 B-37 8-38 RECEPTACLE ABOVE---n � 1 ffi��h,: 1 l' - -,1!1I,,-- - � G -, ,-, -�,- 18-43) , � I r..---r �8-39 ""'-·"--''---QUADS ABOVE � 1 ,1 f r " 8-41 OUTLET FOR VACUUM 1 YELLOW ) - oeF . . COUNTER UNLESS B-9 , (B-35) UNDER CABINET, 1 BLUE I OTHERWISE NOTED B-18,20 PROPOSED 60A-2P/ NON-FUSIBLE K MECHANICAL ROOM ·' . ' / / GFI SWITCH ON COUNTER IN 2 SINGLE GANG BOX 8- IDc©I J r � GANG BOX w/ UNDER ¾" CONDUIT I '- GFI _ j ,· � - � CABINET LIGHT SWITCH I I DISCONNECT IN NEMA 4X S.S ENCLOSURE PROPOSED 30A-2P NON-FUSIBLE DISCONNECT IN NEMA 4X S.S. ENCLOSURE B-28,30 CU-2 AH-2 POWERED VIA CU-2 PROPOSED RAS/WAS VFD'S AND DVDT FIUERS (TYP. OF 3) WP GFl B-9 / / TO PROPOSED RAS/WAS LIFT STATION, SEE SITE PLAN FOR CONTINUATION 1---,--,--, // , / / . I "7 Ir 1 YELLOW ' - LABORATORY l"!l fo MOUNTED 11 ARCHITECTURAL -c��7i [ FLUSH I •1 • / NOTE: SEE LAB .. B-11 RESTROOM I 1 1 BLUE I, JUI QUAD , , 8-'3 I SINGLE GANG BOX ELEVATIONS '--,--,!-----lf,,..J o FOR CLARITY // : I ¾" CONDUIT (2) CONNECTIONS -ETHERNET FOR INTERNET -ETHERNET FOR SCADA I \ '.J---j ; SCADA TV MONITOR le 8-4 CONTRACTOR TO COORDINATE ELECTRICAL REQUIREMENTS TO ISLAND DURING CONSTRUCTION ROUTE CONflUIT U �DER SLAB YELLOW � 1 BLUE SINGLE GANG BOX 8-40.,'@· / 'I G /@ 8�31 • -"- 1 -'----MINI-FRIDGE G I=-,.' UNDER COUNTER , ¾" CONDUIT EXHAUST FAN AT ROOF, INTERLOCK w/ LOUVER SEE STRUCTURAL AND HVAC PLANS FOR MORE INFORMATION \ \ ' ELECTRICAL ROOM PROPOSED---!� OXIDATION DITCH CONTROL PANEL '-JI 8-14 / . J__,-MDPB-4 ,, PROPOSED --- -, SCADA PANEL CHEMICAL FEED ROOM 8-7 WP GFI TO PROPOSED OXIDATION DITCH, SEE SITE PLAN FOR CONTINUATION I--,---,__ ' 1---, _ _ ,_ _, 1---, _ _ ,_ _ , w 8-17 PROPOSED 120/208V-30---i LIGHTING PANEL "8'' I PROPOSED 75KVA-30 TRANSFORMER 480V-30PRIMARY 120/208V-3o, 4W SECONDARY, ' ON 4" CONCRETE HOUSEKEEPING PROPOSED OXIDATION DITCH VFD'S AND DVDT FILTERS (TYP. OF 4) I W I ROPOSED 480V-30 MAIN POWER (3) 3" SPARES FROM DIV. I PULLBOX--+- -- w .. STUBBED UP IN ELECTRICAL ROOM _/ _ DISTRIBUTION PANEL "MD t B" \ C- '-;c__ E E EE E E� "' ) w l---2 RUNS OF 3" SCH. 80 PVC II I \ I \ �<-- ' <- - E CONDUIT, SEE ONE LINE FOR TO EXISTING HEADWORKS ?---E--< ,--,--,-' MORE INFORMATION BUILDING, SEE SITE PLAN FOR CONTINUATION I \ POWER PLAN SCALE; ¼" - 1'-0" 8-16 tM-''l---PUMP SKID SCADA JI'--'"--'-'-' BULK TANK 'LEVEL READOUT ' 11 '- PANEL SHIPPED LOOSE INSTALLED ON WALL PANEL 200 AMPERES B 120,/208 VOLTS 4WIRE CIRCUIT ITEM FEED NO. 1 INTERIOR LIGHTS 3 EXIT & EXTERIOR LIGHTS 5 REFRIGERATOR RECEPTACLE 7 EXTERIOR RECEPTACLES 9 MECHANICAL ROOM RECEPTACLES 11 RESTROOM RECEPTACLES 13 ELECTRICAL ROOM RECEPTACLES 15 CHEMICAL FEED ROOM PUMP SKID 17 CHEMICAL FEED BLDG. SCADA PANEL 19 AIR HANDLER UNIT 21 CHEMICAL FEED ROOM UNIT HEATER 23 CLARIFIER SCADA PANEL LOAD CNTR. 25 OXIDATION DITCH LIGHTING 27 OOIORP PROBE TRANSMITTER 29 ELEC. ROOM INTERNET RECEPTACLE 31 MINI FRIDGE UNDER COUNTER 33 SCAOA COMPUTER 35 LAB VACUUM SWITCHED RECEPT. 37 LAB COUNTER QUAD RECEPTACLE 39 LAB COUNTER QUAD RECEPTACLE 41 LAB INCUBATOR 43 SOLIDS OVEN 45 SPACE 47 SPACE 49 SPACE 51 SPACE 53 SPACE MCBMAIN CONNECTION .'i PHASE KAIC WIRE CU. SIZE AMPS POLE BUS 12 20 1 A 12 20 1 8 12 20 I C 12 20 1 A 12 20 1 8 12 20 1 C 12 20 1 A 12 20 1 8 12 20 1 C 12 20 1 A 12 20 1 B 10 30 1 C 12 20 1 A 12 20 1 8 12 20 1 C 12 20 1 A 12 20 I B 12 20 1 C 12 20 1 A 12 20 1 B 12 20 1 C 12 20 1 A B C A 8 C CHEMICAL FEED BUILD I NG flECTRICAI ROOM LOCATION POLE 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 SIJREACE MOUNTING S.E.L. WIRE AMPS SIZE ITEM FEED 20 12 CHEMICAL FEED ROOM LIGHTS 20 12 LAB COUNTER RECEPTACLES 20 12 OFFICE RECEPTACLES 20 12 STORAGE CLOSET RECEPTACLES 20 12 DISHWASHER 20 12 OFFICE RECEPTACLES CIRCUIT NO. 2 4 6 8 10 12 20 12 CHEMICAL FEED ROOM RECEPTACLES 14 20 12 BULK TANK LEVEL READOUT 16 35 10 CONDENSING UNIT 20 20 12 WATER FOUNTAIN 22 20 12 OFFICE RECEPTACLES 24 20 12 OXIDATION DITCH RECEPTACLES 26 30 10 ELECTRICAL ROOM MINI-SPUT 30 20 12 SCADA TV 32 20 12 CONVENIENCE OUTLETS 34 20 12 LAB COUNTER QUAD RECEPTACLE 36 20 12 LAB COUNTER QUAD RECEPTACLE 38 20 12 LAB COUNTER QUAD RECEPTACLE 40 20 12 OFFICE RECEPTACLES 42 20 12 SPARE 44 SPACE 46 SPACE 48 SPACE 50 SPACE 52 SPACE 54 NOTE: UPDATE WIRE AND C.B. TO MECHANICAL EQUIPMENT PER MANUFACTURERS INSTALLATION REQUIREMENTS NOTE: CONTRACTOR TO PROVIDE TYPED AND LAMINATED PANEL SCHEDULES FOR "AS-BUILT" INSTALLATION AT COMPLETION OF PROJECT. MOUNT FIXTURE @ 12'-0" A.F.F 8& "D" LIGHTING PLAN SCALE; ¼" � 1'-0" 0 I I ' - I,, B-3 -¢-r - NEW CHEMICAL FEED BUILDING REVISIONS 9/ /207' ' g . ;; -= g (.) '""§ i� ;;_• :'Efi "' " BID SET © 2021 /llidw�,tem Engineers. Inc. 302 Wes! Broadw:,y .Srn. 'C! PO. Box 295 Lc>ogvotee. Indiana 47553 DATE SEPT. 2021 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 20'15078-01 E1 .01 103 OF 114 FILE NUMBER 41969 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2