0 0 w J z J m w w 0 g' ;; �I = § 0 0 I � m � >w "� w -c � I N- N9 �� �� ;a§ .w -� �� -c - Q. I "o ►0 oz o-, ·\ 00 •< .. 09 • i, N '= " . ::i <c NEW CHEMICAL FEED BUILDING SCADA SYSTEM NOTES THE CONTRACTOR SHALL UTILIZE THE OWNERS EXISTING SCAOA SYSTEM INTEGRATOR DEQ, INC. BY CONTACTING DONNIE QUALKENBUSH AT 812-525-8358 FOR SCOPE AND ANY QUESTIONS PRIOR TO BID. THE PROPOSED SCADA CONTROL PANEL SHALL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO, THE FOLLOWING A NEMA 12 ENCLOSURE B. CIRCUIT BREAKERS C. TVSS D. ALLEN BRADLEY CDMPACTLOGIX PLC w/ EXPANSION 1/0 E. DIGITAL AND ANALOG 1/0 CARDS F. AUTOMATION DIRECT C-MORE TOUCHSCREEN G. FIBER OPTIC PATCH PANEL H. MANAGED NCTWORK SWITCH FOR SCADA NETWORK I. MANAGED GIGABIT NCTWORK SWITCH FOR INTERNET NCTWORK J. 24VDC POWER SUPPLY K. CONTROL RELAYS L. TERMINAL BLOCKS M. UPS BATTERY BACKUP N. LED INTERIOR CONTROL PANEL LIGHT BAR 2. INPUTS/OUTPUTS DIGITAL INPUTS, CHEMICAL FEED PUMP #1 RUN STATUS (ON/OFF) CHEMICAL FEED PUMP #1 RUN STATUS (ALARM) CHEMICAL FEED PUMP #1 IN-REMOTE STATUS CHEMICAL FEED PUMP #2 RUN STATUS (ON/OFF) CHEMICAL FEED PUMP #2 RUN STATUS (ALARM) CHEMICAL FEED PUMP #2 IN-REMOTE STATUS DIGITAL OUTPUTS, CHEMICAL FEED PUMP #1 CALL CHEMICAL FEED PUMP #2 CALL ANALOG INPUTS, BULK STORAGE TANK LEVEL CHEMICAL FEED PUMP #1 SPEED REFERENCE CHEMICAL FEED PUMP #2 SPEED REFERENCE ANALOG OUTPUTS CHEMICAL FEED PUMP #1 PACING SIGNAL (PACED OFF INFLUENT FLOW) CHEMICAL FEED PUMP #2 PACING SIGNAL (PACED OFF INFLUENT FLOW) ETHERNET, OXIDATION DITCH CONTROL PANEL SCAOA PC RAS/WAS PUMP #1 VFD RAS/WAS PUMP #2 VFD RAS/WAS PUMP #3 VFD FIBER, CLARIFIER CONTROL PANEL HEADWORKS BUILDING SCADA PANEL I ., .-��- - � 0 � � MECHANICAL ROOM t I I ' -,-, -----, I 11@]] 1 I I : : 1--0--1 I- --1 I • I I I I l!I I c ] I I I L ---1..L _J I ' ,/, ,.•'-\. / 'L = ' � I r._ I 1) ' ,, n I ' � ' I I / / -- � NOTE CHEMICAL FEED PUMPS TO BE PACED OFF INFLUENT FLOW METER n CHEMICAL FEED PUMP SKID DIGITAL AND ANALOG TO SCADA PER 1/0 LIST • f _",;;�ti ; I -� """1 1111 CHEMICAL FEED SCAOA PANEL CHEMICAL FEED ROOM I " I BULK TANK ' ���=a. I I / --7"1DIGITAL READOUT FOR BULK STORAGE � • TANK LEVEL, PRECISION DIGITAL II TO SCADA ==-=== ,,,-- ---: 1 �====SJ' 'p' ' " 11 /l_� 11: MODEL #PD765-6R3-10 IN NEMA 1 STEEL ENCLOSURE 0 ' './ �---Ir- .«�- m>$ ,I 'c ' / C) - ' ' ,,,..' ''"-'• ,' ' ' : • _,,, ' ·� ,, / ' 2" SCADA DIV. I PULL BOX �" [ FIBER/INTERNET TO �n�t�t=��p=' =' �TI I I I ' ' ' ' □ ,, CONTROL TO CONTROL TO OXIDATION SCAOA " PROPOSED 75KVA-30 TRANSFORMER 480V-3¢ PRIMARY k/ ' I/ ' ,· ' ' CONTROL PANEL CONTROL PER 1/0 UST PANEL PER 1/0 LISTING ELECTRICAL ROOM PROPOSED 480V-30 MAIN POWER DISTRIBUTION PANEL "MOPS" ETHERNET TO SCADA ETHERNET TO OXIDATION DITCH CONTROL PANEL � - ' ' ,. ' ': ·, ' ' 120/208V-3¢, 4W SECONDARY, ON 4" CONCRETE HOUSEKEEPING PAD 11 C t2.. SCAOA FIBER/INTERNET TO _CLARIFIER SCAOA PANEL VIA DIV. I PULL BOX [;rl� � ; -' M M Of M NOTL SEE 1/0 LIST AND \ ;:--. ,. ,,• , , • ; NETWORK DIAGRAM FOR "' ; � /. '� ADDITIONAL INFORMATION ' � .;, .;,\\/,' PROPOSED RAS/WAS VFD S '---; , t i ✓ ' PROPOSED OXIDATION DITCH ANO DVDT FILTERS (TYP OF 3) , ,/ VFD'S AND DVDT FILTERS (TYP. OF 4) CONTROLS PLAN VFD'S ELECTRICALLY INTERLOCKED (HARDWIRED) TO LOCAL MOTOR DISCONNECTS AS SHOWN ON PROPOSED ONE LINE DIAGRAM FOR "RUN ENABLE". CONDUITS SHOWN FOR CLARITY BUT CAN BE RAN TOGETHER, SEPARATE FROM OTHER POWER AND CONTROL. SCALE, ¼" = 1'-0" NEW CHEMICAL FEED BUILDING REVISIONS 9/'/702' BID SET © 2021 Midv.,·.,tcrn Engintcri,. Jm:. 802 We.st Bro:1dwny St"'cl P.O. Box 295 Loogwtec. l11diana 47553 DATE SEPT. 2021 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W PROJECT NUMBER 2015078-01 E1 .02 104 OF 114 FILE NUMBER 41968 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2