� w z w �' � > 11' 0 0 0 N I !, �w Q_ tu "• � ' N- NO N� a,,, a: Sl �\ �� ,;w •" 0� -· �I �� "a >" - oz 131 g-, �� ;.; "" i � CN ' •• ' Cl 0 • I � . CONTRACTOR TO PROVIDE AND INSTALL 2 4"0 QUAZITE PULL BOX, SIZE PER NEC (TYPICAL) COORDINATE LOCATION w/ OWNER AND ENGINEER DURING CONSTRUCTION PRIOR TO INSTALLATION E ------'/48DV-3¢ DIGITAL CONTROL TO OXIDATION DITCH CONTROL PANEL (1") E ------'/ 480V-3¢ ACTUATED VALVES (1 ") TO NEW CHEMICAL FEED BUILDING, SEE SITE PLAN FOR CONTINUATION PB "A" E ------'/ 1 2 0V-1¢ D0/0RP TRANSMITTER (1") E ------'/ 1 2 0V-1¢ LIGHTS (1" ) E ------'/120V-1 ¢ RECEPT. (1") E ------'/ 480V-3o MOTOR #4 BELDEN CABLE (2") E ------'/ 480V-30 MOTOR #3 BELDEN CABLE (2'') E ------'/D0/0RP SIGNAL CABLES (1'') E ------'/ 2" SPARE TO CHEM FEED BUILDING VFD INTERLOCK WIRING IN CONDUIT TO MOTOR #3 AND #4 VFD'S IN CHEMICAL FEED BUILDING (1") PULL BOX DETAIL "A" ENLARGED FOR CLARITY NEW OXIDATION DITCH SCADA SYSTEM NOTES 1. THE OXIDATION DITCH CONTROL PANEL SHALL BE PROVIDED B Y MANUFACTURER, INSTALLED B Y CONTRACTOR AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2. INPUTS/OUTPUTS DIGITAL INPUTS, TO NEW CHEMICAL FEED BUILDING, SEE SITE PLAN FOR CONTINUATION OXIDATION DITCH INFLUENT VALVE STATUS (OPEN/CLOSED) OXIOATION DITCH STORM VALVE STATUS (OPEN/CLOSED) DIGITAL OUTPUTS, OXIDATION DITCH INFLUENT VALVE CLOSE COMMAND OXIDATION DITCH STORM VALVE OPEN COMMAND ANALOG INPUTS: ORP PROBE DO PROBE ANALOG OUTPUTS ETHERNET CHEMICAL FEED BUILDING SCADA PANEL OXIDATION DITCH ROTOR #1 VFD OXIDATION DITCH ROTOR #2 VFD OXIDATION DITCH ROTOR #3 VFD OXIDATION DITCH ROTOR #4 VFD CONTRACTOR TO PROVIDE AND INSTALL 24"0 QUAZITE PULL BOX, SIZE PER NEC (TYPICAL). COORDINATE LOCATION w/ OWNER AND ENGINEER DURING CONSTRUCTION PRIOR TO INSTALLATION. E ------'/ 480V-3¢ MOTOR # 2 BELDEN CABLE ( 2 ") � PB ------'/ VFD INTERLOCK WIRING IN CONDUIT TO MOTOR #2 � "B" ' AND #3 VFDS IN CHEMICAL FEED BUILDING (1") E 2" SPARE TO CHEMJ FEED BUILDING E ------'/ 48DV-3¢ MOTOR #1 BELDEN CABLE (2") r---RAS/WAS PUMP #1 480V-3¢ BELDEN CABLE ( 2 ") f-'-'---RAS/WAS PUMP #2 480V-3¢ BELDEN CABLE (2") J-'----RAS/WAS PUMP #3 480V-3¢ BELDEN CABLE (2") " J------ACTUATED VALVES 4BOV-3¢ (1") 1 " 1 " 11 j-,--���·:, �:�� e.-�-- - - - -120V-1¢ (1") FIBER TO CHEMICAL FEED BUILDING ( 2 ") 17----------RAS/WAS PUMP VFD INTERLOCK WIRING (1") PULL BOX DETAIL "B" ENLARGED FOR CLARITY SEE DETAIL THIS SHEETJ FOR ENLARGED PULL BOX INFORMATION NOTE, SOME CONDUITS MA Y NOT BE SHOWN FOR CLARITY, PROVIDE CONDUIT AND WIRE AS REOUIRED FOR FULLY FUNCTIONAL S Y STEM SEE DETAIL THIS SHEET- FOR ENLARGED PULL BOX INFORMATION INSTALL 3-WAY WEATHER PROOF SWITCH FOR OXIDATION DITCH CONVENIENCE LIGHTING PROVIDE AND INSTALL D0/0RP TRANSMITTER/ANAI. Y ZER � MOUNTED ON ALUMINUM UNISTRUT. PROVIDE 120V-1< POWER AND CONTROL WIRING IN SEPARATE CONDUITS CONTROL TO OXIDATION AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM DITCH CONTROL PANEL I [ I ! I I ' I I I I I 480V-3¢ TO VFD IN CHEMICAL FEED BLDG. B-27 �---�---�-,,-rl-+-m �l=•=·==l=il=\;c==¼i=l=i==15HP MOTOR #4 ::r==-------111,a: Q �,c=[ll - -:. -tiflt::�!!!!�:: r-- 1 1tt-� IN � S � T � AL � L _,_ W � EA � T _ H _ ER -- P � R � O _ O -_ F -_- C � O � N � V - E - NIENCE PROVIDE AND INSTALL 480V, 60A-3P NON-FUSED � ..,._ c: RECEPTACLE IN CAST ALUMINUM BOX w/ DISCONNECT IN NEMA 4X S . S. ENCLOSURE. ' PROVIDE SLAB MOUNTED UNISTRUT STAND FOR PROBE SIGNAL CABLING IN ...,._._ IN USE STYLE METAL COVER (TYP. OF 3) DISCONNECT, STAINLESS STEEL HARDWARE SHALL CONDUIT ALONG RAILING . ,· rt'llif3s .· B- 2 6: BE USED FOR INSTALLATION. LENGTHS ORDERED BY "' -..- CONTRACTOR (NO SPLICES) '• �• PROVIDE AND INSTALL ORP PROBE, BRACKETING AND WIRING PER MANUFACTURERS RECOMMENDATIONS. E] w PROVIDE AND INSTALL DO PROBE,/ BRACKETING AND WIRING PER MANUFACTURERS RECOMMENDATIONS. • PROVIDE AND INSTALL 480V, 60A-3P NON-FUSED DISCONNECT IN NEMA 4X S.S. ENCLOSURE. PROVIDE SLAB MOUNTED UNISTRUT STAND FOR DISCONNECT, STAINLESS STEEL HARDWARE SHALL BE USED FOR INSTALLATION - ,...·� .:...;:�. t:o� �. 480V-3¢ TO VFD IN ' . rJJ' MDPB-12 � TO OX DITCH CONTROL PANEL, -VALVE CONTROL (OPEN/CLOSE) -VALVE STATUS (OPEN/CLOSED) AUTOMATED INFLUENT VALVE, NORMALL Y OPEN ENERGIZE TO CLOSE, CONTROLLED ,---;>++c1+--,gy OXIDATION DITCH CONTROL PANEL . ', I 8-25 INSTALL LED DUSK TO DAWN LIGHT ON 1¼" ALUMINUM CONDUIT APPROX 8' ABOVE GRATING (TYP. OF 5) TO OX DITCH CONTROL PANEL, o -VALVE CONTROL (OPEN/CLOSE) \ -VALVE STATUS (OPEN/CLOSED) "STORM MODE" AUTOMATED INFLUENT VALVE, NORMALLY CLOSED ENERGIZE TO OPEN, CONTROLLED BY OXIDATION DITCH CONTROL PANEL 30 HP MOTOR #3 CHEMICAL FEED BLDG. I " E " . � i •' � _, 480V-30 TO VFD IN J�� � B � - :.: 2 :' 5 �t--�. 30 HP MOTOR CHEMICAL FEED BLDG. _ ., . , ,,. � � �� B. -26: • PROVIDE AND INSTALL 480V, 60A-3P NON-FUSED DISCONNECT IN NEMA 4X S.S. ENCLOSURE. PROVIDE SLAB MOUNTED UNISTRUT STAND FOR INSTALL WEATHER PROOF CONVENIENCE RECEPTACLE IN CAST ALUMINUM BOX w/ IN USE STYLE METAL COVER (TYP. OF 3) DISCONNECT, STAINLESS STEEL HARDWARE SHALL BE USED FOR INSTALLATION. . - IJ C 1 � I I' .�.� �a,, - . ' � . ""lfi► '' "'l"""- - � � ---i!f!iF .J..a. -.,.Ill)� ·•••U� -- -·� � lliiil!S-- .'"-,� , re:r. "E" B-2s9" ·B-26 WP . 3FJ • ' T • PB �::::j+J==:='tJ:+=i= = =1 5 HP MOTOR #1 "8" [ 480V-3¢ TO VFD IN CHEMICAL FEED BLDG. PROVIDE AND INSTALL 480V, 60A-3P NON- USED DISCONNECT IN NEMA 4X S.S. ENCLOSURE. PROVIDE SLAB MOUNTED UNISTRUT STAND FOR DISCONNECT, STAINLESS "E" STEEL HARDWARE SHALL BE USED FOR INSTALLATION. 8-25 INSTALL 3-WAY WEATHER PROOF SWITCH FOR--���- ,.J�--.... ...:.1 ..., ' ,.• ,..!, '..lal __, 1 ,,: 1 ""' , ,.!,, I -""1� ....,, ....,,t!J OXIDATION orrcH CONVENIENCE LIGHTING 0 NEW OXIDATION DITCH - ELECTRICAL PLAN SCALE, 3/16" � 1'-0" NOTE ALL BURIED CONDUITS SHALL BE SCH. 80 PVC w/ LONG SWEEP ELBOWS. ALL EXPOSED CONDUITS SHALL BE ALUMINUM FASTENED w/ STAINLESS HARDWARE. REVISIONS 9/' /202" BID SET © 2021 �!idwest,·m Engine�r,;. In�. 802 West 13ro,1dw;1v S1ree1 P.O. llm 295 l0<)1,!<IIM�. Jndiam47553 DATE SEPT. 2021 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 E2.01 105 OF 11 4 FILE NUMBER 41967 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2