� � �I � i:i - Q �i � � 0 � < �� (al l z 0 w 0 w' i = �I z ;: w �w "� $� . I N- N9 NO 0� �g -- -o ·� • w .� 0� �" -� "o >U oz o-, 00 � < u9 LN Ee '5 iii "" , ------------------------------------------- 7 I I • • • • ,:;a POLYMER METERING PUMP, INTERLOCK TO RUN w/ SLUDGE PUMP(S) VIA SCADA SYSTEM ,. ___,. • • • • SCADA NOTE: I I I I I � � � w_ I 120V-10 � •I .[ TO SCADA PER 1/0 /7 J'\ - '\ • • 1.INTEGRATOR TO PUT SOFTWARE SELECTOR SWITCH ON (2) EXISTING SLUDGE PUMPS. OWNER WILL MANUALLY SELECT WHEN SLUDGE PUMP #1 OR #2 IS WASTING. WHEN EITHER PUMP IS WASTING OR GRAVITY, INTERLOCK POLYMER FEED PUMP TO RUN. ' • � >---SLUDGE/FLOCCULANT ■ MIXER • !u So �, -0 "B s. I I I I I I I I I I I I I I (3) #6 THWN I ) #10 CU. GND I • -(); i'(r., - • CONDUIT j TO PANEL "C" , _ _ , , --e- -e -EL- � IN CONTROL "8" I j l�+--SQUARE D, 12 CKT., 60A, 1 BUILDING ' "' • • • 12DV-1¢ • • • lMODULAR FIBERGLASS COMPOSITE BUILDING, 12'-O"x1o'-O"x7'-6"H • C-1,2 • • LOAD CENTER, FIELD VERIFY � LOCATION w/ELECTRICAL I CONTRACTOR PRIOR TO • INSTALLATION. CONNECT ALL ELECTRICAL WIRING, IN CONDUIT, AS REQUIRED FOR • FULLY FUNCTIONAL SYSTEM I NOTE: CONTRACTOR IS RESPONSIBLE FOR MAKING ALL ELECTRICAL CONNECTIONS INSIDE PROPOSED CHEMICAL FEED BUILDING AS REQUIRED FOR FULLY FUNCTIONAL SYSTEM. SEE SPECIFICATIONS AND CIVIL PLANS FOR MORE INFORMATION. L---------�---------------------------------� POLYMER FEED BUILDING ELECTRICAL PLAN SCALE: 1/2" - 1'-0" SIZED BY CONTRACTOR HINGED COVER----,- _::; �--, INSTALL CLASS I DIV. I RATED CABLE GROMMET FOR CABLES FROM POWER/CONTROL RACK a Z "'- NCTION BOX WITH VENT NEMA 4X S .S . POWER DISTRIBUTION BLOCKS MOUNTED TO BACKPANEL INSIDE JUNCTION BOX INSTALL CABLE GRIPS TO SUPPORT CABLE OUT OF PULL BOX (TYP. 3) .,..------ VENTED ALUMINUM WIRE MESH CABLE GUARD w/ HINGED ACCESS m · . . ' .· ., ·='llilliil="""='fi+-�co RE DRILL ENTRY • TO WETWELL (TYP.) WET WELL JUNCTION BOX DETAIL NOT TO SCALE LENGTH OF STAND x 4' DEEP ' .. 24 , , . .. • .•. • ; . : . ' . . ' ... : ,, . . ; . ,• . ,. ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) Y , " STAINLESS STEEL ALL-THREADS IN CONCRETE 10TH AS REQUIRED TO ADEQUATELY SUPPO T EQUIPMENT • 4"x4"x½j_" ALUM. ANGLE ��½" ALUM. BASE PLATE PROVIDE 4" SQUARE WOVEN WIRE REINFORCEMENT IN FOUNDATION BASE DETAIL NOT TO SCALE NOTE: LOCATE JUNCTION BOX 5' FROM VENT SUCH THAT IT IS NOT A TRIP HAZARD. Blue River Technologies Port-A-Poly w/Blue White A2 Series Pump Neat Polymer Suction Hose w/Barrel Wand I I I I I I I I I I Polymer Drum PAK 524 S�ill Deck Stainless Steel Shelf Floor Level Note: 1 4" Sludge/Flocculant Mixer w/4" Schd80 Flanged end connec. Poly Tank Out to Dewotering Pad Incoming Water Line Install 1" Brass Shutoff Valve CHEMICAL FEED DETAIL NOT TO SCALE CONTINUOUS HINGED NEMA 4X S.S. VENTED I JUNCTION BOX SEE DETAIL THIS SHEET �� □ '�[ C C, - I. t '\�-=,- . . J \,"� � ' INSTALL CONDUITS SLAB ( T YPICAL) / '� UNDER t: ' ' ! 480V NON-FUSIBLE - - TRANSFER PUMP STATION CONTROL PANEL IN NEMA 4X S.S ENCLOSURE ,_, -t ----,: FIBER TO WWTP SCADA PANEL ,_ E-:==--iE� / CONTROL WIRING J E------C IN CONDUIT TO VFD FOR :=== E r DISCONNECT ' , INTERLOCK I I .,:u I I u I I 0 � I I �.,: I I 0 In from Sludge pumps TRANSFER PUMP CONTROL PANEL SCADA SYSTEM NOTES 1. 2. THE CONTRACTOR SHALL UTILIZE THE OWNERS EXISTING SCADA SYSTEM INTEGRATOR DEQ, INC. BY CONTACTING DONNIE QUALKENBUSH AT 812-525-8358 FOR SCOPE AND ANY QUESTIONS PRIOR TO BID. THE PROPOSED CONTROL PANEL SHALL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO, THE FOLLOWING: A. NEMA 4X S.S. ENCLOSURE K. PILOT LIGHTS FOR TRANSFER PUMPS RUNNING B. CIRCUIT BREAKERS L. PILOT LIGHTS FOR TRANSFER PUMPS VFD FAIL C. TVCC M PILOT LIGHTS FOR TRANSFER PUMPS SEAL LEAK D. PANEL HEATER N. PILOT LIGHTS FOR TRANSFER PUMPS HIGH TEMP E. ALLEN BRADLEY CDMPACTLOGIX REMOTE 1/0 0. POTEMTIOMETER FOR TRANSFER PUMPS HAND SPEED CONTROL F. FIBER OPTIC PATCH PANEL P. PUMP PROTECTION RELAYS (PROVIDED BY PUMP MANUFACTURER) G. MANAGED NETWORK SWITCH FOR SCADA NETWORK Q. INTRINSICALLY SAFE BARRIERS H. 24VDC POWER SUPPLY R. CONTROL RELAYS I . H-0-A SELECTOR SWITCHES FOR TRANSFER PUMPS S. TERMINAL BLOCKS J. DIGITAL DISPLAY FOR TRANSFER PUMP WETWELL LEVEL T. UPS BATTERY BACKUP INPUTS/OUTPUTS DIGITAL INPUTS· TRANSFER PUMP STATION HIGH LEVEL FLOAT TRANSFER PUMP STATION LAG ON FLOAT TRANSFER PUMP STATION LEAD ON FLOAT TRANSFER PUMP STATION OFF FLOAT FINAL CLARIFIER #1 RUN STATUS (ON/OFF) FINAL CLARIFIER #1 HIGH TORQUE FINAL CLARIFIER #1 HIGH TORQUE SHUTDOWN ALARM FINAL CLARIFIER #2 RUN STATUS (ON/OFF) FINAL CLARIFIER #2 HIGH TORQUE FINAL CLARIFIER #2 HIGH TORQUE SHUTDOWN ALARM TRANSFER PUMP #1 H-0-A POSITION TRANSFER PUMP #1 SEAL LEAK TRANSFER PUMP #1 HIGH TEMP TRANSFER PUMP #2 SEAL LEAK TRANSFER PUMP #2 HIGH TEMP TRANSFER PUMP #2 H-0-A POSITION DIGITAL OUTPUTS: TRANSFER PUMP #1 RUN STATUS (ON/OFF) PILOT LIGHT TRANSFER PUMP #1 RUN STATUS (ALARM) PILOT LIGHT TRANSFER PUMP #2 RUN STATUS (ON/OFF) PILOT LIGHT TRANSFER PUMP #2 RUN STATUS (ALARM) PILOT LIGHT POLYMER FEED PUMP START COMMAND ANALOG INPUTS: WET WELL LEVEL TRANSFER PUMP #1 POTENTIOMETER TRANSFER PUMP #2 POTENTIOMETER ANALOG OUTPUTS FIBER: WWTP CONTROL PANEL UV CONTROL PANEL U. LED INTERIOR CONTROL PANEL LIGHT BAR FIBER TO WWTP SCADA PANEL ALUMINUM UNISTRUT __;:;,.L_ 7W'TRANSFER PUMP STATION MDPC-1 MDPC-2 / / 4"x4" ALUMINUM ----1 CONTROL ANGLE PANEL ., - J:c�-480V NON-FUSIBLE - DISCONNECT IN NEMA 4X CONTINUOUS HINGED NEMA 4X S.S. VENTED JUNCTION BOX, SEE DETAIL THIS SHEET NEMA 4X S.S. S.S ENCLOSURE (TYP.), WIRE INTERLOCK WIRING IN CONDUIT TO VFD IN CONTROL BUILDING ELECTRICAL ROOM. ·- -ei:-s;..-- SEE BASE DETAIL THIS SHEET DISCONNECT IN NEMA 4X S .S. ENCLOSURE (TYP.) 480V-30 TO WWTP CONTROL BUILDING PROPOSED RADAR TRANSDUCER, VEGA WL61 -+TO LOCAL CONTROL � t-- : EL VIA � U � ON BOX ; ELECTRICAL PLAN SCALE: 3/8"-1 '-0" SEAL LEAK AND HIGH TEMP TO LOCAL CONTROL PANEL VIA JUNCTION BOX (TYP. OF 2) (2) 20HP 480V-3o 27 FLA ,, - NOTE: STATION TO MAINTAIN LEVEL VIA RADAR LEVEL SENSOR UNDER NORMAL OPERATION, FLOATS ARE BACKUP • HIGH FLOAT LAG ON FLOAT T OFF FLOAT ELECTRICAL RISER NOT TO SCALE: EXISTING TRANSFER PUMP STATION • - � � �: 21 � ,, • £ REVISIONS 9/'/707· BID SET © 2021 Midv.c,1crn E�gineers. lnc. 802 West Broadway Street P.O. Box 295 Loogootee, lnclim," -17553 DATE SEPT. 2021 DESIGN AS.B. DRAWN C.N.M. O.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 E4.01 108 OF 11 4 FILE NUMBER 41964 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2