i w m w 0 z �' 0 z o' N - � . � � � is 0 o' m ,ffi ae ow 0 a .,; . N9 " Nm o,- No -o N, � Co m� • .w ~e Q ---- 8� � "11 ,;a � a> rO 'ti oz " 8� " " " ,< < � 0� .. Q .� ial 5c , " � ·<a CONTROL BUILDING SCADA SYSTEM NOTES THE CONTRACTOR SHALL UTILIZE THE OWNERS EXISTING SCADA SYSTEM INTEGRATOR DEQ, INC. BY CONTACTING DONNIE QUALKENBUSH AT 812-525-8358 FOR SCOPE AND ANY QUESTIONS PRIOR TO BID. THE PROPOSED SCADA CONTROL PANEL SHALL INCLUDE, BUT NOT NECESSARILY BE LIMITED TO, THE FOLLOWING, A NEMA 12 ENCLOSURE T. PILOT LIGHTS FOR RAW PUMPS SEAL LEAK B. POWER DISTRIBUTION BLOCK U. PILOT LIGHTS FOR RAW PUMPS HIGH TEMP C. PHASE MONITOR V H-0-A SELECTOR SWITCHES FOR SLUDGE PUMPS D MOTOR CIRCUIT BREAKERS SIZED FOR RAW PUMPS W. NORMAL/OFF/WASTE SELECTOR SWITCH FOR SLUDGE PUMPS E. NEMA SIZE 1 MOTOR STARTERS FOR RAW PUMPS X. PILOT LIGHTS FOR SLUDGE PUMPS RUNNING F. MOTOR CIRCUIT BREAKERS SIZED FOR SLUDGE PUMPS Y PILOT LIGHTS FOR SLUDGE PUMPS FAIL G. NEMA SIZE 2 MOTOR STARTERS FOR SLUDGE PUMPS Z. PILOT LIGHTS FOR SLUDGE PUMPS SEAL LEAK H. MOTOR CIRCUIT BREAKERS SIZED FOR STANDBY SLUDGE PUMPS AA. PILOT LIGHTS FOR SLUDGE PUMPS HIGH TEMP I NEMA SIZE 1 MOTOR STARTERS FOR STANDBY SLUDGE PUMPS BB PUMP PROTECTION RELAYS (PROVIDED BY PUMP MANUFACTURER) J. CONTROL TRANSFORMER CC H-0-A SELECTOR SWITCHES FOR DIGESTER MIXER K. CIRCUIT BREAKERS DD. PILOT LIGHTS FOR DIGESTER MIXER RUNNING L. ALLEN BRADLEY COMPACTLOGIX PLC w/ EXPANSION 1/0 EE. PILOT LIGHTS FOR DIGESTER MIXER FAIL M. AUTOMATION DIRECT C-MORE TOUCHSCREEN FF. PILOT LIGHTS FOR STANDBY SLUDGE PUMP RUNNING N. FIBER OPTIC PATCH PANEL GG. PILOT LIGHTS FOR STANDBY SLUDGE PUMP FAIL 0. MANAGED NETWORK SWITCH FOR SCADA NETWORK HH INTRINSICALLY SAFE BARRIERS P 24VDC POWER SUPPLY II. CONTROL RELAYS Q. H-0-A SELECTOR SWITCHES FOR RAW PUMPS JJ. TERMINAL BLOCKS R. PILOT LIGHTS FOR RAW PUMPS RUNNING KK. UPS BAITTRY BACKUP S. PILOT LIGHTS FOR RAW PUMPS FAIL LL. LED INTERIOR CONTROL PANEL LIGHT BAR 2. INPUTS/OUTPUTS DIGITAL INPUTS, DIGESTER HEAT EXCHANGER STATUS RAW PUMP STATION HIGH LEVEL FLOAT RAW PUMP STATION LAG ON FLOAT RAW PUMP STATION LEAD ON FLOAT RAW PUMP STATION OFF FLOAT SLUDGE PUMP STATION HIGH LEVEL FLOAT SLUDGE PUMP STATION HIGH LAG ON FLOAT SLUDGE PUMP STATION HIGH LEAD ON FLOAT SLUDGE PUMP STATION OFF FLOAT PANEL 200 AMPERES C 120/208 VOLTS 'WIRE CIRCUIT I NO. ITEM FEED _1_ POLYMER FEED BUILDING 3 5 SUMP PUMP IN LOWER LEVEL 7 DEHUMIDIFIER IN LOWER LEVEL 9 DIGESTER COVER LEVEL CONVERTER 11 SPARE 13 INTERMEDIATE LEVEL LIGHTS 15 INTERMEDIATE CONVENIENCE RECEPT. 17 DIGESTER MIXER LIGHT AND RECEPT. cJ2_ CONDENSING UNIT 21 23 SPARE 25 SPARE 27 SPARE 29 SPARE 31 SPARE 33 SPARE 35 SPARE 37 SPARE 39 SPARE 41 SPACE 43 SPACE 45 SPACE 47 SPACE 49 SPACE 51 SPACE 53 SPACE MCBMAIN CONNECTION 'PHASE KAIC WIRE CU. SIZE AMPS POLE BUS 6 60 2 A B 12 20 1 C 12 20 1 A 12 20 1 8 12 20 1 C 12 20 1 A 12 20 1 8 12 20 1 C 12 25 2 A B 10 30 1 C 12 20 1 A 12 20 1 B 12 20 1 C 12 20 I A 12 20 1 B 12 20 1 C 12 20 1 A 12 20 1 8 C A 8 C A 8 C POLE 3 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 CQt:JIRQI Bllll Qlt-JG El ECI8IC8I ROOM LOCATION SURFACE MOUNTING S.E.L . WIRE ITEM FEED ! CIRCUIT AMPS SIZE NO 100 3 PANEL "O" e..L 6 20 12 SLUDGE SUPPLY FLOW METER TRANS 8 20 12 MAIN LEVEL LIGHTS 10 20 12 ROOF VENTILATION EXHAUST FAN 12 20 12 RAW!SLUDGE WETWELL EXH. FAN 14 20 12 EXTERIOR LIGHTS (CONTROL BLDG.I 16 20 12 EXTERIOR LIGHTS (POLE MOUNTED'\ 18 25 12 CONDENSING UNIT � 22 20 12 SPARE 24 20 12 SPARE 26 20 12 SPARE 28 20 12 SPARE 30 20 12 SPARE 32 20 12 SPARE 34 20 12 SPARE 36 20 12 SPARE 38 20 12 SPARE 40 SPACE 42 SPACE 44 SPACE 46 SPACE 48 SPACE 50 SPACE 52 SPACE 54 DIGESTER MIXER RUN STATUS (ON/OFF) DIGESTER MIXER RUN STATUS (ALARM) DIGESTER MIXER H-0-A STATUS NOTE: CONTRACTOR TO PROVIDE TfPED AND LAMINATED PANEL SCHEDULES FOR "AS-BUILT" INSTALLATION AT COMPLETION OF PROJECT. RAW PUMP #1 RUN STATUS (ON/OFF) RAW PUMP #1 RUN STATUS (ALARM) RAW PUMP #1 H-0-A POSITION RAW PUMP #2 RUN STATUS (ON/OFF) RAW PUMP #2 RUN STATUS (ALARM) RAW PUMP #2 H-0-A POSITION STANDBY SLUDGE PUMP RUN STATUS (ON/OFF) STANDBY SLUDGE PUMP RUN STATUS (ALARM) SLUDGE PUMP #1 RUN STATUS (ON/OFF) SLUDGE PUMP #1 RUN STATUS (ALARM) SLUDGE PUMP #1 H-0-A POSITION SLUDGE PUMP #2 RUN STATUS (ON/OFF) SLUDGE PUMP #2 RUN STATUS (ALARM) SLUDGE PUMP #2 H-0-A POSITION SLUDGE PUMPS NORMAL-OFF-WASTE SELECTOR SWITCH POSITION (NORMAL) SLUDGE PUMPS NORMAL-OFF-WASTE SELECTOR SWITCH POSITION (WASTE) DIGITAL OUTPUTS DIGESTER MIXER START COMMAND SLUDGE PUMP #1 START COMMAND SLUDGE PUMP #2 START COMMAND ANALOG INPUTS: FLOATING DIGESTER COVER POSITION (I.E. TANK LEVEL) SLUDGE FLOW METER INSTANTANEOUS FLOW ANALOG OUTPUTS ETHERNff TRANSFER PUMP TRANSFER PUMP #1 VFD #2 VFD iOO NOTE, EXISTING LIGHTS OUTSIDE OF THE PROPOSED ELECTRICAL ROOM TO BE REWIRED ANO FULLY FUNCTIONAL FROM PROPOSED PANEL "c". 0 I v' [ F· · � /1\ �'li===�����a;c l',, = =,l[ I I ';!!/ 1 \ \ �·: q i<-<t \ \ ,,. "B ,., " ...-.-""7l Qi d�_:;- "B" MAIN LEVEL LIGHTING PLAN SCALE: ¼."=·1'-0" 4 S.S CABLE CONVERTING COVER LEVEL VIA TRANSDUCER ON BRACKET NEAR ROOF EXISTING 10.QAMPERES _M_GB_MAIN CONNECTION "'.0.b!J.RQLB. LllLDJb!G__ELECIRI.CliiL. RD_D_M. LOCATION PANEL /_ SlJBCSCC L __J,ZQ-20.8. VOLTS ___ ,J PHASE _ ��MOUNTING P 1 ' WIRE __ _,_ KAIC .. S.E.L. CIRCUIT ITEM FEED �1;: I AMPS POLE CU. POLE I AMPS WIRE ITEM FEED NO. 1 B A US 1 20 S 1 IZ 2 E POLE '1 CIRCUIT NO �UPPE�LEVEL BLDG. LIGHTS 12 , _,2"0 -+ -'--+� IL'__ 3 EXTERIOR BLDG. LIGHTS_ --1 iL+--20 1 B 1 I 20 12 MIDDLE LEVEL BUILDING 4 5 BLDG. RECEPTACLES & EF-4 72 20 1 C 1 20 12 MIDDLE LEVEL & LOWER RECEPT. 6 7 RECEPT. DIG ALARM CABINET 12 20 1 A 1 :zcJI J2 LOWER LEVEL LIGHT 8 9 INCUBATOR 12 20 1 8 1 20 12 LAB COUNTER RECEPTACLE 10 � UNDER COUNTER REFRIGERATOR 12__20 -+- 1 C 1 2Q.. _ 12 LAB COUNTE��CEPTACLE __ 12 13 EF-1 & EF-2 12 20 .,.._1 -! A 1 20 . 12 SPARE_ ___ 14 15 CL2 ROOM RECEPTACLE 12 20 1 B ----.- -1 �_1Q_ JL MMP 16 17 EF-3 & I.AB CENTER RECEPTACLE 12 20 1 C 1 20 12 FLOW RECORDER FIT-07 18 19 1 EF-5 & EWC - -- - -, 12 -20 1 'A I 1 20 - 12�L2 LEAK DETECTOR 20 21 BUBBLER AIR COMPRES�OR &____g_A�12 20 1 B 1 20 12 __JlOW TRANSJ 0ITTER FIT-1] __ 22 23 BASEMENT EXHAUST FAN 10 30 1 C 1 20 12 , WATER HEATER 24 ' - 25 SITE RECEPTACLE 12 20 1 A 2 30 10 THRU WALL A/C 26 27 SUMP PUMP 12 20 I 1 I B I _ 28 f- 29 l:QLE LIGHT #2 - -_. 12 20 1 i C I I 1 1 : I 20 12 POLE_ LIGHT _jf____4_ 30 J1_ �OLE LIGHT & RECEPTACLLJ5 _.___1_2 -�-1 A _J_, _,____�OJ_ 12 f POLE LIGHT 16 __J...32 33 SPARE ---,---12 ---;-- 20 1 B i 1 20 12 �L2 ROOM LIGHT 34 ,_15 SPARE 12 20 1 C i 1 I 30 10 SPARE __ ~36 37 120/208V GENERATOR & 12 20 3 A 1 I 30 10 SPARE __ _ 38 100A PANEL 8 1 20 12 iSPACE + 4 . Q_ , 1 C !SPARE ____Lg NOTE: 120V-10 LOADS REMAINING IN USE FROM THIS PANEL SHALL BE RECONNECTED AND FULLY FUNCTIONAL FROM PANEL "C" MOTOR RATED SWITCH, WIRED TO FAN ON ROOF MAIN LEVEL POWER PLAN SLUDGE WETWELL #1 NOTE: INDOOR UNITS POWERED FROM OUTDOOR UNITS, INSTALL PER MANUFACTURERS INSTALLATION RECOMMENDATIONS REVISIONS BID SET © 2021 /11idwestc•m Engint'crs. Jnc. 802 Wc,1 llro;,dway Street PO Llox 29S l<..>c,ll,OOl��- Jndinn:1 --17553 DATE SEPT. 2021 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 E?.02 11 2 OF 11 4 FILE NUMBER 41960 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2