Midwestern Engineers, Inc. Plan Preview

0 "' fl I � �· □ 0 □ 0 �· i i' o' ,w <ffi �� "'" � ' N" oq 1:� NO 0 - � �- z !! § � � •w �� �" Q "" z• � <o •□ � ---- w� "o :i: a--, "< m� i,i cN � � � - Q <� PIKE COUNTY PIKE COUNTY COMMISSIONERS GENERAL NOTES HIGHWAY SUPERINTENDENT ROGER HAM PH. 1-812-354-9743 552 N. STATE ROAD 61 PETERSBURG, INDIANA 47567 MARK FLINT JEFF NELSON RYAN COLEMAN COUNTY COMMISSIONERS OFFICE 801 E. MAIN STREET, SUITE#2 PETERSBURG, IN 47567 1. THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICAN VERTICAL DATUM (NAVO 88) PH: 812-354-8448 INDIANA DEPARTMENT OF TRANSPORTATION VINCENNES DISTRICT 3650 SOUTH U.S. 41 VINCENNES, IN 47591 PH: 1-800-279-5758 FAX: 1-812-895-7479 UTILITIES ELECTRICAL: DUKE ENERGY 3001 W. BROADWAY ST. PRINCETON, IN 47670 PH: 1-812-3951605 WORK PH: 1-812-463-2212 MOBILE DARON SCHAUS$ daron.schauss@duke--energy.com HOLEY MOLIY SAYS, "CALL BEFORE YOU DJG" (lWO WORKING DAYS PLEASE) WATER/SEWER CITY OF PETERSBURG. 704 E. MAIN ST. PETERSBURG, IN 47567 PH: 1-812-354-8511 WORK PH· 1-812-582-2628 MOBILE ROSS ELMORE relmore@petersburg,in.gov 1-800-382-5544 INSIDE INDIANA 1-800-428-5200 FROM OUTSIDE IN� PROJECT LOCATION - GAS VECTREN 211 NW RIVERSIDE EVANSVILLE, IN 47708 PH: 1-812-491-5010 WORK PH: 1-812-305-0296 MOBILE BRAD V AN BIBBER brad. van bibber@centerpointenergy.com CABLE: WAVE COMMUNICATIONS 102 N 5TH ST., P O BOX 557 VINCENNES, IN 47591 PH: 1-812-887-8996 BART KOTTTER ba1i.kotter@wavecom.com WHITE RIVER WASTEWATER SYSTEM IMPROVEMENTS - DIV. II EXISTING WASTEWATER TREATMENT PLANT IMPROVEMENTS TELEPHONE INDIANA FIBER NETWORK, LLC 5520 W. 76TH ST. INDIANAPOLIS, IN 46268 PH: 1-317-777-7119 TELEPHONE: PERRY-SPENCER RURAL TELEPHONE CO-OP, INC. 11877 E. SR 62 ST MEINRAD, IN 47577 PH· 1-812-357-2123 FRONTIER COMMUNICATIONS 401 MERRITT 7 NORWALK, CT 06851 1-800-921-8101 PSC (PERRY-SPENCER TELEPHONE CO-OP) 402 E 4TH STREET, STE. A HUNTINGBURG, IN 47542 1-800-511-4899 L.S.#1 2. THE CONTRACTOR SHALL CALL INOIANA UNDERGROUND SERVICES AT 1-800-382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 3. DOWN TIME COORDINATION MUST BE MADE WITH THE SEWER UTILITY PRIOR TEMPORARILY SHUTTING DOWN A SEWER MAIN AND/ OR LIFT STATION. COORDINATE WITH CITY SERVICES MANAGER, ROSS ELMORE, AT 812-582-2628 (CELL), A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED. 4. TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES CULVERTS DRIVES. EXISTING UTILITIES, POINTS OF CONNECTION, ETC HOWEVER, THE EXACT LOCATION AND olJANTITIES , SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 5. PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT THE PROPERTY SURVEYS , BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. 6. THE LOCATION OF EXISTING UTILITIES, ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA 7. EXACT LOCATION OF MANHOLES, LATERALS, CLEANOUTS, ETC TO BE DETERMINED AT THE TIME OF CONSTRUCTION. 8. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURE (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. 9 IF ANY ARCHAEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY AT 1-317-232-1646. NO ADDITIONAL EXCAVATION WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 10. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U.S. FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES. 11 CONTRACTOR SHALL MINIMIZE DISTURBANCE TO CITY STREETS (INCLUDING BUT NOT LIMITED TO SPRUCE STREET) TO THE GREATEST EXTENT POSSIBLE IN ACCESSING THE PROJECT SITE. SPRUCE STREET WILL NOT BE RESURFACED AS PART OF THE PROJECT SCOPE DUE TO OTHER PROJECTS THAT WILL BE OCCURRING ONSITE. THE PLACEMENT OF TEMPORARY GRAVEL SHOULD BE USED TO AVOID RUTTING IN AREAS WHERE EXISTING ASPHALT PAVING DOES NOT ALLOW FOR PROPER TURNING MOVEMENTS. CONTRACTOR SHALL AVOID IMPACT TO ADJACENT PROPERTIES OUTSIDE OF CITY RIGHTS OF WAY SCALE: 1" = 1ODO' 0 WATER TREATMENT PLANT - BACKWASH HOLDING TANK· SEE DIV. I FOR ADDITIONAL INFORMATION L.$.#4 EQUALIZATION BASIN AND HEAOWORKS BUILDING - SEE DIV. I F TION L.S.#� FOURSTARLS. WASTEWATER COLLECTION SYSTEM LIFT STATION 3 & 5 IMPROVEMENTS, SEE DIV. Ill FOR ADDITIONAL INFORMATION LS12 •�9 L.S. #1 PROJECT LOCATION MAP SHEET NUMBER LEGEND G1 .01 SHEET DESIGNATOR _J r1t SHEET SEQUENCE SHEET TYPE OR STRUCTURE� DENOTES A STRUCTURE NUMBER SHEET 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 SHEET DESIGNATOR KEY: G GENERAL INFORMATION & DESIGN V SURVEY/ MAPPING SD SITE DEVELOPMENT/ GEOTECHNICAL C CIVIL D DEMOLITION/ RENOVATION S STRUCTURAL A ARCHfTECTURAL Q EQUIPMENT P PLUMBING M MECHANICAL - PROCESS PIPING AND CHEMICAL FEED MH MECHANICAL/ HVAC E ELECTRICAL SC SYSTEM CONTROLS R RESOURCES/ EXISTING FACILITY DRAWINGS Z SHOP DRAWINGS SHEET TYPE OR STRUCTURE DESIGNATOR KEY: 100 GENERAL PLAN SHEETS: CIVIL PLAN SHEETS; SEPTAGE RECEIVING SYSTEM AND TYPICAL DETAILS SHEETS NEW STRUCTURES 1.0 OFFICE/ LAB/ CHEMICAL FEED BUILDING 2.0 OXIDATION DITCH 3.0 NEW & EXISTING CLARIFIERS FLOW SPLITTER BOX: NEW FINAL CLARtFIERS No. 1 & 2 AND RAS/WAS PUMP STATION 6.0 U.V. DISINFECTION ANO STEP AERATION TANK AND U.V. STORAGE BUILDING 7.0 MIXING PUMP BUILDING 8.0 CONTAINER BAG SLUDGE DEWATERING SYSTEM AND POLYMER FEED BUILDING EXISTING STRUCTURES TO BE RENOVATED 4.0 TRANSFER PUMP STATION AND VALVE VAULT 5.0 EXISTING FINAL CLAR!FIERS No. 1 & No. 2 AND SLUDGE DRAW-OFF PIT 7.0 CONTROL BUILDING; ANAEROB!C DIGESTER AND WASTE GAS BURNER 8.0 SLUDGE DRYING BEDS EXISTING STRUCTURES TO BE DEMOLISHED 4_0 RETURN PUMP STATION AND RECIRCULATION PUMP STATION 9.0 PRIMARY SETTLING TANKS • TRICKLING FILTER CHLORINE CONTACT TANK U.V. DISINFECTION TANK AND U.V. STORAGE BUILDING SHEET SCHEDULE (CONT'D) PAGE DESCRIPTION 9.01 PRIMARY SETTLING TANK - DEMOLITION PLANS 9.02 PRIMARY SETTLING TANK - DEMOLITION SECTIONS 9.03 PRIMARY SETTLING TANK - DEMOLITION SECTIONS 9.04 PRIMARY SETTLING TANK - DEMOLITION SECTIONS 9.05 TRICKLING FILTERS - DEMOLITION PLAN 9.06 TRICKLING FILTERS - DEMOTION SECTIONS ANO DETAILS 9.07 CHLORINE CONTACT TANK - DEMOLITION PLAN AND DETAILS 9.08 EXISTING ULTRAVIOLET DISINFECTION - DEMOLITION PLAN VIEWS AND DETAILS E101 ELECTRICAL SITE PLAN WEST E102 ELECTRICAL SITE PLAN EAST E103 EXISTING POWER DISTRIBUTION ONE LINE DIAGRAM E104 PROPOSED POWER DISTRIBUTION ONE LINE DIAGRAM E1.01 LAB/ CHEMICAL FEED BUILDING - LIGHTING AND POWER PLAN E1.02 LAB/ CHEMICAL FEED BUILDING - CONTROLS PLAN E2.01 OXIDATION DITCH - ELECTRICAL PLAN E3.01 NEW FINAL CLARIFIER$ AND RAS/ WAS PUMP STATION - ELECTRICAL PLAN E3.02 NEW FINAL CLARIFIERS ANO RAS/ WAS PUMP STATION - ELECTRICAL DETAILS E4.01 EXISTING TRANSFER PUMP STATION - ELECTRICAL PLAN E5.01 EXISTING FINAL CLARIFIER$ - ELECTRICAL PLAN E6.01 NEW U.V. DISINFECTION I STEP AERATION - ELECTRICAL PLAN E7.01 CONTROL BUILDING I ANAEROBIC DIGESTER INTERMEDlCATE LEVEL - ELECTRICAL PLAN E7.02 CONTROL BUILDING/ ANAEROBIC DIGESTER MAIN LEVEL - ELECTRICAL PLAN SC101 PROPOSED SCADA NETWORK DIAGRAM - WEST SC102 PROPOSED SCADA NETWORK DIAGRAM - EAST SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 SHEET SCHEDULE PAGE DESCRIPTION 1 COVER SHEET G101 PROJECT LOCATION MAP, SHEET SCHEDULE AND GENERAL NOTES G102 DESIGN SUMMARY G103 FLOW DIAGRAM G104 HYDRAULIC PROFILE G105 HYDRAULIC PROFILE V101 SITE BOUNDARY SURVEY SD101 SOIL BORING LOCATION MAP AND SOIL BORING LOGS SD102 EROSION CONTROL PLAN AND DETAILS C101 EXISTING SITE RENOVATION PLAN C102 OVERALL SITE IMPROVEMENTS AND STRUCTURE LOCATION PLAN C103 SITE GRADING PLAN C104 SITE GRADING PLAN C105 OVERALL SITE PIPING ANO UTILITIES PLAN C106 SITE PIPING PLAN AND UTILITES PLAN C107 SITE PIPING PLAN AND UTILITES PLAN C108 PIPING PLAN AND PROFILES C109 PIPING PLANS AND PROFILES C110 TYPICAL DETAILS AND MANHOLE/ STRUCTURE SCHEDULE C111 TYPICAL SITE DETAILS C112 TYPICAL SITE DETAILS C113 PARKING PLAN AND SITE DETAILS S114 STRUCTURAL GENERAL NOTES AND TYPICAL DETAILS S1.01 OFFICE/ LAB/ CHEMICAL FEED BUILDING - FOUNDATION PLAN S1.02 OFFICE/ LAB/ CHEMICAL FEED BUILDING - ROOF FRAMING PLAN A1.03 OFFICE/ LAB/ CHEMICAL FEED BUILDING - FLOOR PLAN A1 04 OFFICE/ LAB/ CHEMICAL FEED BUILDING· REFLECTED CEILING PLAN A1.05 OFFICE I LAB/ CHEMICAL FEED BUILDING - ELEVATIONS A1.06 OFFICE/ LAB/ CHEMICAL FEED BUILDING· BUILDING SECTIONS A1.07 OFFICE/ LAB/ CHEMICAL FEED BUILDING - WALL SECTIONS A1.08 OFFICE/ LAB/ CHEMICAL FEED BUILDING - OFFICE CABINETS AND RESTROOM ELEVATIONS, DETAILS ANO SCHEDULES A1.09 OFFICE/ LAB/ CHEMICAL FEED BUILDING - LAB, PLAN VIEW, ELEVATIONS, AND SCHEDULES A1.10 OFFICE/ LAB/ CHEMICAL FEED BUILDING - DOOR AND WINDOW ELEVATIONS AND SCHEDUILES A1.11 OFFICE/ LAB I CHEMICAL FEED BUILDING - DOOR AND WINDOW DETAILS P1.12 OFFICE/ LAB/ CHEMICAL FEED BUILDING - DOMESTIC WATER PLUMBING PLAN P1 13 OFFICE/ LAB/ CHEMICAL FEED BUILDING· SANITARY SEWER PLUMBING PLAN P1.14 OFFICE/ LAB/ CHEMICAL FEED BUILDING - PLUMBING SCHEDULES M1 15 OFFICE/ LAB/ CHEMICAL FEED BUILDING - CHEMICAL FEED PLAN M1.16 OFFICE/ LAB/ CHEMICAL FEED BUILDING - CHEMICAL FEED EQUIPMENT SCHEDULES AND DETAILS H1.17 OFFICE I LAB/ CHEMICAL FEED BUILDING - HVAC PLAN, SCHEDULES AND DETAILS S2 01 OXIDATION DITCH - FOUNDATION PLAN AND DETAILS S2 02 OXIDATION DITCH - UPPER LEVEL PLAN AND DETAILS S2.03 OXIDATION DITCH - TOP VIEW PLAN S2.04 OXIDATION DITCH - ELEVATIONS S2.05 OXIDATION DITCH· TANK SECTIONS S2.06 OXIDATION DITCH· SECTIONS AND DETAILS S2.D7 OXIDATION DITCH - SECTIONS AND DETAILS S2.08 OXIDATION DITCH • SECTIONS AND DETAILS S2 09 OXIDATION DITCH - SECTIONS AND DETAILS S2.10 OXIDATION DfTCH - SECTIONS AND DETAILS M2.11 OXIDATION DITCH- MECHANICAL PIPING PLAN S3.01 NEW & EXISTINGCLARIFIERS FLOW SPLITTER BOX. NEW FINAL CLARIFIERS, RAS/ WAS PUMP STATION -FOUNDATION PLAN M3.02 NEW & EXISTING CLARIFIERS FLOW SPLITTER BOX. NEW FINAL CLARIFIERS. RAS I WAS PUMP STATION - LOWER LEVEL/ MECHANICAL PLAN & PIPING EQUIPMENT SCHEDULE S3.03 NEW & EXISTING CLARIFIER$ FLOW SPLITTER BOX, NEW FINAL CLARIFIERS, RAS I WAS PUMP STATION - UPPER LEVEL PLAN S3.04 NEW & EXISTING CLARIF!ERS FLOW SPLITTER BOX, NEW FINAL CLARIFIERS, RAS/ WAS PUMP STATION - SECTIONS AND DETAILS S3.05 NEW & EXISTING CLARIFIER$ FLOW SPLITTER BOX, NEW FINAL CLARIFIERS, RAS/ WAS PUMP STATION - SECTIONS AND DETAILS S3.06 NEW & EXISTING CLARIFIERS FLOW SPLITTER BOX, NEW FINAL CLARIF!ERS, RAS/ WAS PUMP STATION SECTIONS AND DETAILS S3.07 NEW & EXISTING FINAL CLARIFIERS - LAUNDER COVER PLAN VIEW S3.08 NEW & EXISTING FINAL CLARIFIERS - LAUNDER COVER - SECTIONS AND DETAILS S3.09 NEW & EXISTING FINAL CLARIFIERS - LAUNDER COVER - SECT!ONS AND DETAILS S3.10 NEW & EXISITNG FINAL CLARIFIERS -WEIR AND SCUM BAFFLE - SECTIONS AND DETAILS S3.11 NEW FINAL CLARIFIERS - CURRENT BAFFLE - SECTIONS ANO DETAILS 4.01 EXISTING TRANSFER, RECIRCULATION AND RETURN PUMP STATIONS- PLAN VIEWS 4.02 EXIST\NG TRANSFER, RECIRCULATION AND RETURN PUMP STATIONS - SECTIONS 4.03 EXISTING TRANSFER PUMP STATIONS - PLAN VIEW AND SECTIONS 5.01 EXISTING FINAL CLARIFIERS AND SLUDGE DRAW-OFF PIT· DEMOLITION PLAN 5.02 EXISTING FINAL CLARIFIERS AND SLUDGE DRAW-OFF PIT - DEMOLITION DETAILS 5.03 EXISTING FINAL CLARIFIERS - RENOVATION PLAN & DETAILS S6.01 UV DISINFECTION/ STEP AERATION STRUCTURE AND U.V. STORAGE BUILDING - FOUNDATION PLAN AND DETAILS M6.02 U.V. DISINFECTION/ STEP AERATION STRUCTURE AND U.V. STORAGE BUILDING· LOWER LEVEL/ MECHANICAL PLAN AND DETAILS S6.03 U.V. DISINFECTION/ STEP AERATION STRUCTURE AND U.V. STORAGE BUILDING - TOP VIEW PLAN AND DETAILS A6.04 U.V. DISINFECTION STORAGE BUILDING - PLAN AND DETAILS 7.01 CONTROL BUILDING/ ANAEROBIC DIGESTER· PIPING PIT & LOWER LEVEL DEMOLITION PLAN 7.02 CONTROL BUILDING/ ANAEROBIC DIGESTER - INTERMEDIATE LEVEL DEMOLITION PLAN 7.03 CONTROL BUILDING/ ANAEROBIC DIGESTER - MAIN LEVEL DEMOLITION PLAN 7.04 CONTROL BUILDING/ ANAEROBIC DIGESTER- PIPING PIT LEVEL RENOVATION PLAN 7.05 CONTROL BUILDING/ ANAEROBIC DIGESTER- LOWER LEVEL RENOVATION PLAN 7.06 CONTROL BUILDING/ ANAEROBIC DIGESTER - INTERMEDIATE LEVEL RENOVATION PLAN 7.07 CONTROL BUILDING/ ANAEROBIC DIGESTER - SECTIONS AND DETAILS 7.08 CONTROL BUILDING I ANAEROBIC DIGESTER - MAIN LEVEL RENOVATION PLAN 7.09 CONTROL BUILDING/ ANAEROBIC DIGESTER - ROOF LEVEL RENOVATION PLAN AND DETAILS 7.10 EXISTING ANAEROBIC DIGESTER - DUO-DECK FLOATING COVER PLAN & SECTIONS 7.11 CONTROL BUILDING/ ANAEROBIC DIGESTER - STAIRS PLANS AND DETAILS 7.12 CONTROL BUILDING/ ANAEROBIC DIGESTER - INTERMEDIATE LEVEL PLUMBING AND H.V.A.C 7.13 CONTROL BUILDING/ ANAEROBIC DIGESTER - MAIN LEVEL PLUMBING AND H.V.A.C. 7.14 WASTE GAS BURNER - PLAN & DETAILS 8.01 SLUDGE DRYING BEDS - RENOVATION PLAN 8.02 CONTAINER BAG SLUDGE DEWATERING SYSTEM AND POLYMER FEED BUILDING - PLAN VIEW, SECTIONS AND DETAILS 8.03 CONTAINER BAG SLUDGE DEWATERING SYSTEM AND POLYMER FEED BUILDING· PLAN VIEW, SECTIONS. DETAILS AND PIPING SCHEDULE 8.04 CONTAINER BAG SLUDGE DEWATERING SYSTEM AND POLYMER FEED BUILDING - SECTIONS OVERALL PROJECT MAP, GENERAL NOTES AND SHEET SCHEDULE ' • REVISIONS 09-19-23 (C) 2021 l\!i(!w�stem l;ngim'crs. l11c, 802 IV6t 13rornlway S!rcct P.O. 80x 295 Loogru1c,:,. [ncti,111a-17553 DATE FEB. 2021 DESIGN C.W.R. DRAWN Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 G101 2 OF 114 F!LE NUMBER 42070 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2