Midwestern Engineers, Inc. Plan Preview

0 � 0 o, I = �' 0 0 0 0 co' �w "� De � ' �� 0� �o ��,::O � �� ·� •w a� -c ' �� �I "o > <> oz g;, ;j �-< .. <>� w oN l; 5S , . <c GENERAL PLUMBING NOTES 1. THESE NOTES APPLY TO ALL PLUMBING DRAWINGS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE SHOWN ON THOSE SHEETS. 2. ALL PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE REQUIREMENTS OF THE INDIANA PLUMBING CODE, 2012 (INTERNATIONAL PLUMBING CODE, 2006 WITH INDIANA AMENDMENTS). COMPLY WITH ADA AND ACCESSIBILITY LAWS AND REGULATIONS AND ALL OTHER AUTHORITIES HAVING JURISDICTION 3. WORK INCLUDES FURNISHING ALL LABOR, MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE, CLEAN-UP, AND SERVICES REQUIRED TO CONSTRUCT AND INSTALL A COMPLETE FULLY OPERATIVE PLUMBING SYSTEM FOR THE PROJECT. 4. ALL NEW WORK IS DRAWN DARK ALL ITEMS DRAWN UGHT ARE EXISTING. EXISTING ITEMS SHALL REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. 5. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACIUTIES DURING CONSTRUCTION. ANY ITEM DAMAGED OR DISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION. PROVIDE PLATING AS REQUIRED TO PROTECT SURFACE OF EXISTING PARKING LOT INCLUDING UNDER WHEELS OF DUMPSTER, LIFTING DEVICES AND OTHER EQUIPMENT THAT COULD SINK INTO ASPHALT. 6. ALL UNDERLINED EQUIPMENT IS SCHEDULED, SEE SCHEDULE SHEETS. 7. CONTRACTOR SHALL COORDINATE WORK WITl-1 ALL OTHER TRADES AND STRUCTURAL CONDITIONS PRIOR TO INSTALLATION. CONTACT ENGINEER WITH CONFLICTS OR DISCREPANCIES. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING AND CUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALL NEW PIPING WHETHER SHOWN OR NOT. 9. ALL PENETRATIONS n-mu RATED CONSTRUCTION TO BE FIRE STOPPED. 10. UNLESS OTHERWISE NOTED, INTERIOR DRAINAGE PIPING SHALL BE INSTALLED AT 1/8' PER FOOT SLOPE. 11. PIPE AND DUCTWORK ROUTINGS SHOWN ON DRAWINGS ARE DIAGRAMMATIC AND ARE A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, I.J.\YOUT, AND CODE COMPLIANCE. 12. SCALES INDICATED ARE FOR ARCHITECTURAL REFERENCE ONLY. DO NOT SCALE DRAWINGS. IT IS NOT INTENDED THAT THE DRAWINGS SHOW EVERY PIPE, DUCT, FITTING, SUPPORTS, ETC., AND IT IS UNDERSTOOD THAT THE DRAWINGS MUST BE FOLLOWED AS CLOSELY AS CIRCUMSTANCES WILL PERMIT, THE PROPER INSTALLATION ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS, LOCAL CODES ANO STANDARD PRACTICES SHALL BE PROVIDED. 13. COORDINATE VENT PENETRATIONS WITH MECHANICAL ROOF TOP EQUIPMENT, REFER TO HVAC DRAWINGS. OFFSET VENTS AS REQUIRED TO MAINTAIN MINIMUM 10'-0' SEPARATION FROM AIR INTAKES. 14. ALL FLOOR MOUNTED EQUIPMENT SHALL BE MOUNTED ON A CONCRETE HOUSEKEEPING PAD. 1 5. CONTRACTOR SHALL FJELD VERIFY EXISTING PIPE ANO EQUIPMENT SIZES, LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR BEGINNING WORK. 16. CONTRACTOR SHALL COORDINATE SHUT DOWN OF ANY MECHANICAL SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, AND ANY OTHER AUTHORITY HAVING JURISDICTION. 17. REMOVE ALL PIPING, VALVES, EQUIPMENT, ETC. MADE OBSOLETE />S A RESULT OF NEW CONSTRUCTION. 18. THOROUGHLY REVIEW All DRAWINGS PRIOR TO ANY DEMOUTION WORK. ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONAL COST TO OWNER. 19. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. 20. PIPING SUPPLIES TO FIXTURES ARE SAME SIZE AS INDICATED IN ROUGH-IN SCHEDULE UNLESS OTHERWISE NOTED ON DRAWINGS. 21. FURNISH ANO INSTALL ALL ITEMS NECESSARY TO MEET THE REQUIREMENTS OF THE UTILITY COMPANY WHETHER INDICATED IN DRAWINGS AND SPECIFICATIONS OR NOT. VERIFY PIPING ROUTING AND RUNS, TAP LOCATIONS, AND INVERT ELEVATIONS REQUIRED PRIOR TO COMMENCING WORK. 22. EXISTING BELOW SI.AB PIPING SHOWN ON THIS Pl.AN HAS BEEN DRAWN FROM AS-BUILT DOCUMENTS, FIELD SURVEYS, AND OTHER AVAILABLE SOURCES. CONTRACTOR MUST USE THESE DOCUMENTS AS A GUIDE TO COMPLETE WORK SHOWN HEREIN ANO INCLUDE IN THEIR BUDGET COSTS FOR MINOR FIELD DEVIATIONS. WHERE MAJOR DEVIATIONS ARE EXPOSED (WHERE THE INTENT OF WORK CANNOT BE COMPLETED AS SHOWN), CONTRACTOR SHALL STOP WORK IN THE EFFECTED AREA AND NOTIFY ENGINEER OF DISCREPANCY. 23. COORDINATE DELIVERY AND STORAGE OF MATERIALS WITH THE OWNER. 24. FURNISH ALL CERTIFICATES OF APPROVALS BY THE PLUMBING INSPECTOR AND BOARD OF HEALTH. 25. MAINTAIN A MINIMUM CLEARANCE OF THREE FEET IN FRONT OF ELECTRICAL PANELS ANO ONE FOOT EITHER SIDE WITH PIPE. 26. INCLUDE IN BID, ALL LICENSE, PERMIT, INSPECTION AND OTHER FEES REQUIRED TO COMPLETE WORK. 27. DURING CONSTRUCTION PROCEDURES, THE ENTIRE WORK AREA SHALL BE CLEAN OF ALL DUST, DIRT AND OTHER DEBRIS BEFORE APPLICATION OF ANY NEW MATERIALS. 28. CONTRACTOR SHALL PROVIDE AND INSTALL NAIL PLATES WHERE PIPING PASSES THROUGH STUD(S) WITHIN 2' OF NAILING SURFACE TO PROTECT PIPE FROM NAILS OR DRYWALL SCREWS. PLAN NOTES 0 ¾" GAS (2PSI) UP TO REGULATOR ASSEMBLY. REFER TO DRAWING Pl.12 FOR CONTINUATION. 0 2" METERED DOMESTIC WATER SERVICE UP TO MAIN SHUTOFF VALVE. REFER TO DRAWING P1.12 FOR CONTINUATION. ,q 3" FD-2 T VTR :---...._3" I / SK-2 I SH-1 = " 1½" / "-f 2 I " SK-1 � 'S / i"-1½ r'\J EWC-1 // 2 '� �� CONDENSATE � � J TRAP o MUD VALVE FD-1 --� ,-:: 4 " � WC-1 // co SANITARY SEWER ISOMETRIC NOTTO SCALE ' ' ' ' ., ' co ' ' ' ' l FD-2 OFFICE ' ,, - ' ,, \, ' ,, STORAGE CLOSET '- ' ' ,, -, OFFICE _, 1¾" METERED GAS SERVICE (2 PSI) F_F_E_ 438.50 t '- � '' ,-," "<._ ,,.__"'-. �-\... - \. ' ' ' ' '- 4"FD MECHANICAL ROOM LABORATORY � 2"/' '- "-J 4" V 4" I " •-1. --- ;,-------� ' ' ' "' ' 2 '- \, --��-- ....:;,.______' 4" " '- 2"w 2"v" 3" 3"W o-.-o [ S-,_ ' "- " f--2" METEREO DOMESTIC WATER SERVICE 1 RESTROOM D 2"FD � -1/ ''-,, ' I{;) 4"FD --''- T 4"FD cQ .......,-=-=--=,_ F.F.E. 434.50 ELECTRICAL ROOM CHEMICAL FEED ROOM MUD VALVE L£J I- t- ' PIPE SLEEVE � � (TYPICAL) "' -,, - - � i - ', CO )�6" SANITARY 6 y INV 431-85' SANITARY SEWER PLAN SCALE:¼" = 1'-0" NEW CHEMICAL FEED BUILDING • - REVISIONS 9/'/2071 BID SET © 2021 �lidwestem E11gjne,,rs. l11{'. SO� \Vc,1 Broadway Street P.O. Box 29� Loogoole�. lndiana 4755J DATE SEPT. 2021 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 P1 .13 36 OF 114 FILE NUMBER 42036 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2