PLUMBING MATERIAL SCHEDULE SYSTEM DOMESTIC WATER SANITARY WASTENENT SANITARY WASTENENT NATURAL GAS NATURAL GAS ABOVE GRADE ABOVE GRADE BELOW GRADE ABOVE GRADE BELOW GRADE HARD COPPER TUBE HARD COPPER TUBE I CAST IRON PVC PVC BLACK STEEL BLACK STEEL POLYETHYLENE MATERIAL TYPE 'L' TYPE 'L' HUBLESS SCHEDULE 40 SCHEDULE 40 SCHEDULE 40 SCHEDULE 40 SDR 11 ASTM B88, NSF 61 I ASTM B88, NSF 61 ASTM A888 ASTM D1784 ASTM D1784 ASTM A53 ASTM A53 ASTM D2513 SIZE 1/2" THRU 4" 1/2" THRU 4" 1-1/2" THRU 6" 1-1/2'' 11-lRU 6" I 2" THRU 6" 1/2" THRU 2" 2-1/2" THRU 4" 1/2" THRU 2'' I I FITTINGS WROUGHT COPPER C0PPER/EPDM CAST IRON DWI PVC DWV PVC DWV MALLEABLE, CLASS 150 WROUGHT STEEL POLYETHYLENE ASME Bl 6.22 ASME B16.51 CISPI 301 ASTM D2665 ASTM D2665 ASME B16.3 ASTM A234 ASTM D2683 JOINTS LEAD-FREE SOLDER PRESS-CONNECT HUBLESS COUPLJNG SOLVENT CEMENT SOLVENT CEMENT THREADED WELDED HEAT FUSION ASTM 832 lAPMO PS-117 CISPI 310 ASTM 02564- ASTM 02564 ASME B1.20.1 AWS Dl0.12 ASTM 02657 COMPLY WITH CDA'S I JOIN TUBE AND COMPLY WITH CISPI COMPLY WITH ASTM COMPLY WITH ASTM COMPLY WITH ASTM INSTALLATION "COPPER TUBE FITTINGS WITH TOOLS "CAST IRON SOIL PIPE 02665 AND 02855, 02321. SANITARY TEES COMPLY WITH INOIANA FUEL GAS CODE I D2774. FURNISH WITH REQUIREMENTS HANDBOOK" RECOMMENDED BY & FITTINGS HANDBOOK" NOT PERMITTED IN AND SHORT-SWEEP CHAPTER 4, "GAS PIPING INSTALLATIONS" PE/STEEL LINE RISER AT FITTING MFR. CHAPTER IV RETURN AIR PLENUMS FITTINGS NOT PERMITTED METER ANO REGULATOR. COMPLY WITH MSS-SP-58 COMPLY WITH MSS-SP-58 COMPLY WITH MSS-SP-58 1/2" THRU 3/4" @ 5' SPACING, 3/8" ROD 1-1/2" THRU 2'' @ 5' SPACING, 3/8" ROD 1/2" THRU 1" @ 8' SPACING, 3/8" ROD HANGERS 1'' THRU 1-1/4" @ 6' SPACING, 3/8" ROD 3" @ 5' SPACING, 1 /2" ROD NOT APPLICABLE 1-1/4" THRU 2" @ 10· SPACING, 3/8" ROD NOT APPUCABLE 1-1/2" THRU 2" @ 8' SPACING, 3/8" ROD 4" @ 5' SPACING, 5/8" ROD 2-1/2" THRU J" @ 10' SPACING, 1/2'' ROD 2-1/2" THRU 4" @ 10' SPACING, 1/2" ROD 6" @ 5' SPACING, 7/8" ROD 4" @ 1Q' SPACING, 5/8" ROD VERTICAL PIPE @ 10' SPACING VERTICAL PIPE @ 10' SPACING VERTICAL PIPE @ 10' SPACING COMPLY WITH ASTM E84 I INSULATION 1" PREFORMED FIBERGLASS WITH ASJ NOT REQUIRED NOT APPLICABLE NOT REQUIRED NOT APPLICABLE ASTM C552, TYPE II, CLASS 2 TEST WITH WATER AT 10' HEAD FOR 2 TEST WITH WATER AT 10' TEST WITH AIR AT 150% WORKING PRESSURE TEST WITH AIR AT 150% TESTING TEST WITH WATER AT 50 PSI ABOVE WORKING HOURS. HEAD FOR 2 HOURS. AIR WORKING PRESSURE (3 PSI PRESSURE FOR 24 HOURS AIR TEST NOT PERMITTED. TtST NOT PERMITTED. (3 PSI MIN) FOR 24 HOURS MIN) FOR 24 HOURS FLUSH WITH POTABLE WATER. FILL SYSTEM REMOVE DIRT AND DEBRIS PURGE SYSTEM TO THE WITH WATER/CHLORINE SOLUTION AT 50 PPM REMOVE DIRT AND DEBRIS AS WORK AS WORK PROGRESSES. PURGE SYSTEM TO THE OUTSIDE WITH NATURAL OUTSIDE WITH NATURAL GAS CLEANING FOR 24 HOURS. FLUSH WITH POTABLE WATER. PROGRESSES. PLUG OPEN ENDS EACH DAY PLUG OPEN ENDS EACH DAY GAS IN ACCORDANCE WITH INDIANA FUEL GAS IN ACCORDANCE WITH SUBMIT WATER SAMPLES TO IDOH. REPEAT WHEN WORK STOPS. WHEN WORK STOPS. CODE, SECTION 406 INDIANA FUEL GAS CODE, UNTIL SATISFACTORY RESULTS ARE OBTAINED. I SECTION 406 PLUMBING EQUIPMENT SCHEDULE ELECTRICAL DATA ITEM DESCRIPTION BASIS OF DESIGN I I CAPACITY INSTALLATION NOTES EQUAL MANUFACTURERS LOAD VOLTS PHASE LOCHINVAR 43 GPH RECOVERY AT 90' RISE, SET OUTLET TEMP AT 140'F A.O. SMITH, BRADFORD WHITE, WH-1 GAS FlRED WATER HEATER GBN0S0-40 - - - 40,000 BTUH INPUT, 50 GAllONS TERMINATE T&P RELIEF RHEEM, STATE ' STORAGE VALVE OVER FLOOR DRAIN I THERMOSTATIC MIXING LAWLER 5.5 GPM AT 10 PSI MAX ½" 140' HOT WATER, ½" BRADLEY, LEONARD, POWERS, TMV-1 VALVE 61-15 - - - PRESSURE DROP 1.0 GPM COLO WATER INLETS, ½" 120' SYMMONS i MINIMUM FLOW HOT WATER OUTLIT I ET-1 EXPANSION TANK AMTROL 2.0 GALLON TANK VOLUME ADJUST PRE-CHARGE PRESSURE BELL & GOSSETT, TACO, ST-5 - - TO MATCH SYSTEM PRESSURE CALEFACTIO I MAXITR0L I 150,000 BTUH TOTAL CONNECTED FURNISH INLET/OUTLET REDUCERS EQUIMETER, FISHER, ROCKWELL, GR-1 GAS REGULATOR I 325-3L-1/2" - - - LOAD, 2 PSI INLET, 11" W.C. OUTLET AS REQUIRED SENSUS I PLUMBING FIXTURE ROUGH-IN SCHEDULE & MOUNTING HEIGHTS ROUGH-IN SIZES FIXTURE DESCRIPTION MOUNTING HEIGHT CW HW TRAP WASTE VENT WC-1 WATER CLOSET - TANK TYPE, ADA 1/2" 4" ,- I 17" TO SEAT - - L-1 UWATORY - WAll HUNG 1/2" 1/2" 1 1/4" 1 1/2" 1 1/2" 34" TO DECK SK-1 SINK - LAB, EYEWASH 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2" BOWL INTEGRAL WITH COUNTERTOP SK-2 SINK - MOP 1/2" 1/2" 3" 3" 2" 36" TO FAUCET SH-1 SHOWER - ADA 1/2" 1/2" - - - 78" (HEAD), 60" (HANDSPRAY), 42" (VALVE) EWC-1 ELECTRIC WATER COOLER - ADA 1/2" - 1 1/4" 1 1/2" 1 1/2" 36" TO BUBBLER IMB-1 ICE MAKER BOX 1/2" - - - - 24" � w HB-1 HOSE BIBB 3/4" - - - - j 24" HY0-1 WALL HYDRANT 3/4" - - - - 18" ABOVE GRADE SS-1 SAFETY SHOWER 1" 1" 1 1/4" 1 1/2" 1 1/2" 82 7/8" HEAD, 37 1/2" BOWL w , ", �' s w 'I" "w N" ��I N9 8� "'0 ��ii� mW - i;; ' �" ii -" a, "o ' �u -1 DZ g;; • >< ' u Sl c � � '" , . <" PLUMBING FIXTURE SPECIFICATIONS FIXTURE BASIS OF DESIGN DESCRIPTION EQUAL MANUFACTURERS WC-1 L-1 SK-1 SK-2 SH-1 tWC-1 IMB-1 V-1 HB-1 HYD-1 SS-1 FD-1 FD-2 co co co WHA AFF AG AP AO ALT BAS BF BG BFP BOP BTU BTUH CB Cl co COND CP csw CV cw OF DIA OS DN OW EC ET EWC EWH FO FS GPM GC GFWH GR HB HR HW HWR HYO FIXTURE: AMERICAN STANDARD 211AA.104 FIXTURE: FLOOR MOUNT, BOTTOM OUTLET, WHITE VITREOUS CHINA, 1.28 GPF, ELONGATED BOWL, ADA, FLUSH TANK FIXTURE: ZURN, KOHLER, SLOAN SEAT: BEMIS 1655SSCT SEAT: MOLDED SOLJD PLASTIC, OPEN FRONT, ELONGATED, EXTRA HEAvY DUTY, SELF-SUSTAINING HINGE SEAT: CHURCH, OLSONITE - CABINET: FAIRMONT DESIGNS 1512-WV3021 CABINET: 30"Wx21"Dx24-1/4"H BATHROOM VANITY, WALL MOUNT, WOOD CONSTRUCTION, WHITE FINISH, TWO DOORS CABINET: N/A TOP: FAIRMONT DESIGNS TC3-3122W1 TOP: 31"x22"x1-1/4" WHITE CERAMIC VANITY SINK TOP WITH INTEGRAL BOWL, SINGLE HOLE FAUCET, OVERFLOW TOP: N/A FAUCET: CHICAGO 3511-E2805AB FAUCET: DECK MOUNT, SOLID BRASS, CHROME Pt.ATE, 0.5 GPM, SINGLE LEVER HANDLE, SINGLE HOLE FAUCET: ZURN, T&S BRASS FIXTURE: N/A FIXTURE: SINK SOWL INTEGRAL WITH COUNTERTOP FIXTURE: N/A SINK FAUCET: CHICAGO 201-AE35ABCP SINK FAUCET: CONCEAL MOUNT, SOLID BRASS, CHROME PLATE, 1.5 GPM, LEVER HANDLES, 9" SWING SPOUT SINK FAUCET: ZURN, T&S BRASS RO FAUCET: WATTS PWFCT303CHA RO FAUCET: DECK MOUNT, CHROME PLATE, AIR GAP CONNECTION, LEVER HANDLE, SWIVEL NECK RO FAUCET: N/A EYEWASH: GUARDtAN G1779, G6020 EYEWASH: DECK MOUNT, EYE/FACE WASH, 90' SWING DOWN, 1/2'' INLET, THERMOSTATIC MIXING VALVE EYEWASH: BRADLEY, HAWS FIXTURE: FIAT MSB2436, MSG2436, 832M, 889CC FIXTURE: FLOOR MOUNT, MOLDED STONE, 24"x36"x10", CAST BRASS DRAIN WITH STAINLESS DOME STRAINER FIXTURE: MUSTEE, STERN-WILLIAMS FAUCET: CHICAGO 897-RCF FAUCET: WALL MOUNT, SOLID BRASS, CHROME Pt.ATE, LEVER HANDLES, CHECK STOPS, VACUUM BREAKER, HOSE THREAD FAUCET: ZURN, T&S BRASS -- - -- -- FIXTURE: SWAN SS-3448, SK-364872 FIXTURE: SOLID SURFACE SINGLE THRESHOLD SHOWER PAN, CENTER DRAIN, sou □ SURFACE WALL KIT, WHITE IN COLOR FIXTURE: JUST FAUCET: SYMMONS 1-117-FS-830-X FAUCET: PRESSURE BALANCE, SINGLE HANDLE, 2.5 GPM, DIVERTER, SLIDEBAR, HAND SPRAY, BRASS HEAD, CHROME FINISH FAUCET: ZURN, T&S BRASS FIXTURE: HALSEY TAYLOR HAC8SS-WF FIXTURE: SINGLE S.S. CABINET, WALL MOUNT BRACKET, PUSH BAR OPERATED, WATER FILTER, 8 GPH CHILLER FIXTURE: OASIS, ELKAY, HAWS - - FIXTURE: GUY GRAY MIB1HAAB FIXTURE: 20 GA STEEL, WHITE POWDER COAT FINISH, 4-3/4"X4-1/8"X3-1/2", HAMMER ARRESTER FIXTURE: ACORN, IPS CORP FIXTURE: CHICAGO 986-909AGVCP FIXTURE: WALL MOUNT WITH Ft.ANGE, SOLID BRASS, CHROME PLATE, SINGLE LEVER HANDLE. SERRATED NOZZLE, VACUUM FIXTURE: ZURN, T&S BRASS -- FIXTURE: WOODFORD MODEL 26 FIXTURE: BRASS BODY. CHROME PLATE, ASSE 1052, HOSE THREAD OUTLET, METAL WHEEL HANDLE FIXTURE: J.R. SMITH, ZURN, JOSAM FIXfURE: WOODFORD MODEL 67 FIXTURE: BRASS BODY, CHROME PLATE, SEPARATE DRAIN TUBE. ASSE 1052, HOSE THREAD OUTLET, WALL CLAMP FIXTURE: J.R. SMITH, ZURN, JOSAM - - FIXTURE: GUARDIAN G1950, G6040 FIXTURE: COMBINATION SHOWER/FACE WASH, PLASTIC SHOWER HEAD, S.S. EYEWASH BOWL, THERMOSTATIC MIXING VALVE FIXTURE: HAWS, BRADLEY, ENCON FIXTURE: J.R. SMITH 2041S-A FIXTURE: CAST IRON, SIDE SPIGOT OUTLET, INTEGRAL TRAP, CLEANOUT, ADJUSTABLE ROUND NICKEL BRONZE TOP FIXTURE: ZURN, J0SAM -- - -- ---- - FIXTURE: J.R. SMITH 2310Y FIXTURE: CAST IRON, BOTTOM NO-HUB OUTLET, MEDIUM DUTY, ADJUSTABLE ROUND NICKEL BRONZE BAR GRATE FIXTURE: ZURN, JOSAM FIXTURE: J.R. SMITH 4101S (CONCRETE) FIXTURE: CAST IRON, SPIGOT OUTLET, BRONZE PLUG WITH GASKET, ROUND SCORIATED NICKEL BRONZE COVER FIXTURE: ZURN, JOSAM -- FIXTURE: J.R. SMITH 4141S (TILE) FIXTURE: CAST IRON, SPIGOT OUTLET, BRONZE PLUG WITH GASKET, ROUND NICKEL BRONZE COVER, TILE RECESS FIXTURE: ZURN, JOSAM FIXTURE: J.R. SMITH 4021S-Y (CARPET) FIXTURE: CAST IRON, SPIGOT OUTLET, BRONZE PLUG WITH GASKET, ROUND NICKEL BRONZE COVER, CARPET MARKER FIXTURE: ZURN, JOSAM - - - - - FIXTURE: J.R. SMITH 5005 FIXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED, POI-A, 3/4" CONNECTION, 1-11 FU RATING FIXTURE: J.R. SMITH 5010 FIXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED, PDl-8, 1'' CONNECTION, 12-32 FU RATING FIXTURE: ZURN, JOSAM SIOUX CHIEF FIXTURE: J.R. SMITH 5020 FIXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED, PDI-C, 1" CONNECTION, 33-60 FU RATING FIXTURE: J.R. SMITH 5030 FIXTURE: STAINLESS STEEL BELLOWS, FACTORY PRESSURIZED, PDI-E, 1" CONNECTION, 61-113 FU RATING PLUMBING SYMBOLS AND ABBREVIATIONS ABBREVIATIONS PLUMBING SYMBOLOGY DRAWING SYMBOLOGY ABOVE FINISHED FLOOR IMS ICE MAKER BOX ----{X]-- SHUTOFF VALVE ABOVE GRADE INV INVERT ELEVATION ACCESS PANEL L LAVATORY r ANGLE VALVE AREA DRAIN LT LAUNDRY TUB -K>t-- BALANCING VALVE ALTERNATE MBH THOUSANDS OF BTU PER HOUR BUILDING AUTOMATION SYSTEM MC MECHANICAL CONTRACTOR " BALL VALVE BELOW FLOOR MH MANHOLE ' BELOW GRADE MS MOP SINK ,, BUTTERFLY VALVE BACKFLOW PREVENTER NPW NON-POTABLE WATER CHECK VALVE BOTTOM OF PIPE NTS NOT TO SCALE ----f'--f- BRITISH THERMAL UNIT ORD OVERFLOW ROOF DRAIN -------&- CONTROL VALVE BTU PER HOUR OSD OPEN SITE DRAIN ' CATCH BASIN PRV PRESSURE REDUCING VALVE PLUG VALVE CAST IRON RD ROOF DRAIN -----0- PRESSURE REDUCING VALVE CLEANOUT RPZ REDUCED PRESSURE BFP CONDENSATE SAN SANITARY DRAIN _£_ SOLENOID VALVE CIRCULATION PUMP SE SEWAGE EJECTOR COLD SOFT WATER SF SQUARE FOOT ',r- SAFETY RELIEt VALVE CONTROL VALVE SH SHOWER COLD WATER SK SINK -=- BACKFLOW PREVENTER DRINKING FOUNTAIN SP SUMP PUMP HOSE BIBB ' DIAMETER ss SAFETY SHOWER DOWNSPOLIT ss STAINLESS STEEL i_j WALL HYDRANT DOWN sr STORM DRAIN 9 PRESSURE GAUGE DISHWASHER TO TRENCH DRAIN ELECTRICAL CONTRACTOR TMV THERMOSTATIC MIXING VALVE Q THERMOMITER EXPANSION TANK TOP TOP OF PIPE ELECTRIC WATER COOLER TYP TYPICAL -------0------ PUMP ELECTRIC WATER HEATER UR URINAL ---f"l- AUTOMATIC AIR VENT FLOOR DRAIN V VENT FLOOR SINK VB VACUUM BREAKER [GMI GAS METER GALLONS PER MINUTE VCP VITRIFIED CLAY PIPE @ GENERAL CONTRACTOR VS VENT STACK WATER METER GAS FIRED WATER HEATER VTR VENT THRU ROOF GAS REGULATOR WB CLOTHES WASHER BOX HOSE BIBB we WATER CLOSET HOSE REEL wco WALL CLEANOUT HOT WATER WHA WATER HAMMER ARRESTER HOT WATER RETURN ws WASTE STACK WALL HYDRANT l'I ZONE CONTROL VALVE r ELBOW TEE £1 PIPE TURNING DOWN - PIPE TURNING UP ----r- TEE UP - TEE DOWN y --0-------- DROP AND RUN --{>-- REDUCER -,ff- UNION STRAINER - y SUSPENDED CLEANOUT - PIPE CAP --- PIPE SLEEVE -><- PIPE ANCHOR ----=- FLEXIBLE CONNECTION FLOW ARROW = PIPE SLOPE DIRECTION 0 FLOOR DRAIN B FLOOR SINK 0 CLEANOUT - - -- - - - csw - - 14 � - - - 14� A G D ---- -- --- II ,;, / Ill 0 0 (] COLD WATER HOT WATER HOT WATER RETURN COLD SOFT WATER 140' HOT WATER 140' HOT WATER RETURN COMPRESSED AIR NATURAL GAS DRAIN/RELIEF - DEMOLITION - VENT SANITARY (ABOVE GRADE) SANITARY (BELOW GRADE) STORM (ABOVE GRADE) STORM (BELOW GRADE) ACID (ABOVE GRADE) ACID (BELOW GRADE) PLAN NOTE DETAIL NUMBER DETAIL/SECTION DRAWING SHEET GENERAL PLUMBING NOTES 1. THESE NOTES APPLY TO ALL PLUMBING DRAWINGS. ADDITIONAL GENERAL NOTES SPECIFIC TO A PARTICULAR DRAWING ARE SHOWN ON THOSE SHEETS 2. All PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE REQUIREMENTS OF THE INOIANA PLUMBING CODE, 2012 (INTERNATIONAL PLUMBING CODE, 2006 WITH INDIANA AMENDMENTS). COMPLY WITH ADA AND ACCESSIBILITY LAWS AND REGULATIONS AND ALL OTHER AUTHORITIES HAVING JURISDICTION. 3. WORK INCLUDES FURNISHING ALL LABOR, MATERIALS, APPLIANCES, EQUIPMENT, TOOLS, TRANSPORTATION, SUPERINTENDENCE, CLEAN-UP, AND SERVICES REQUIRED TO CONSTRUCT AND INSTALL A COMPLETE FULLY OPERATIVE PLUMBING SYSTEM FOR THE PROJECT. 4. All NEW WORK IS DRAWN DARK. ALL ITEMS DRAWN LIGHT ARE EXISTING. EXISTING ITEMS SHALL REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. 5. CONTRACTORS SHALL PROTECT ALL EXISTING OWNER FACIUTIES DURING CONSTRUCTION. ANY ITEM DAMAGED OR DISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION PROVIDE PLATING AS REQUIRED TO PROTECT SURFACE OF EXISTING PARKING LOT INCLUDING UNDER WHEELS OF DUMPSTER. LIFTING DEVICES AND OTHER EQUIPMENT THAT COULD SINK INTO ASPHALT. 6. ALL UNDERLINED EQUIPMENT IS SCHEDULED, SEE SCHEDULE SHEETS. 7. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES AND STRUCTURAL CONDITIONS PRIOR TO INSTALLATION. CONTACT ENGINEER WITH CONFLICTS OR DISCREPANCIES. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR CORE DRILLING AND CUTTING HOLES THRU WALLS AND FLOORS AS REQUIRED TO INSTALL NEW PIPING WHETHER SHOWN OR NOT. 9 ALL PENETRATIONS THRU RATED CONSTRUCTION TO BE FIRE STOPPED. 10. UNLESS OTHERWISE NOTED, INTERIOR DRAINAGE PIPING SHALL BE INSTALLED AT 1/8' PER FOOT SLOPE. 11. PIPE AND DUClWORK ROUTINGS SHOWN ON DRAWINGS ARE DIAGRAMMATIC AND ARE A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, AND CODE COMPLIANCE. 12, SCALES INDICATED ARE FOR ARCHITECTURAL REFERENCE ONLY. DO NOT SCALE DRAWINGS. IT IS NOT INTENDED THAT THE DRAWINGS SHOW EVERY PIPE, DUCT, FITTING, SUPPORTS, ETC , AND IT IS UNDERSTOOD THAT THE DRAWINGS MUSl" BE FOLLOWED AS CLOSELY AS CIRCUMSTANCES Will PERMIT, THE PROPER INSTALLATION ACCORDING TO THE TRUE INTENT AND MEANING OF THE DRAWINGS, LOCAL CODES ANO STANDARD PRACTICES SHALL BE PROVIDED. 13. COORDINATE VENT PENETRATIONS WITH MECHANICAL ROOF TOP EQUIPMENT, REFER TO HVAC DRAWINGS. OFFSET VENTS AS REQUIRED TO MAINTAIN MINIMUM 10'-0' SEPARATION FROM AIR INTAKES. 14. ALL FLOOR MOUNTED EQUIPMENT SHALL BE MOUNTED ON A CONCRETE HOUSEKEEPING PAD. 15. CONTRACTOR SHALL FIELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES, LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR BEGINNING WORK. 16. CONTRACTOR SHALL COORDINATE SHUT DOWN OF ANY MECHANICAL SYSTEM WITH THE OWNER, OCCUPANTS OF THE AFFECTED AREA, AND ANY OTHER AUTHORITY HAVING JURISDICTION. 17. REMOVE ALL PIPING, VALVES, EQUIPMENT, ETC. MADE OBSOLETE AS A RESULT OF NEW CONSTRUCTION. 18. THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY 0EMOLJTION WORK. ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONAL COS1 TO OWNER. 19. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. 20. PIPING SUPPLJES TO FIXTURES ARE SAME SIZE AS INDICATED IN ROUGH-IN SCHEDULE UNLESS OTHERWISE NOTED ON DRAWINGS. 21 FURNISH AND INSTALL ALL ITEMS NECESSARY TO MEET THE REQUIREMENTS OF THE UTILITY COMPANY WHETHER INDICATED IN DRAWINGS AND SPECIFICATIONS OR NOT. VERIFY PIPING ROUTING AND RUNS, TAP LOCATIONS. AND INVERT ELEVATIONS REQUIRED PRIOR TO COMMENCING WORK. 22. EXISTING BELOW SLAB PIPING SHOWN ON THIS PLAN HAS BEEN DRAWM FROM AS-BUILT DOCUMENTS, FIELD SURVEYS, ANO OTHER AVAIi.ABLE SOURCES. CONTRACTOR MUST USE THESE DOCUMENTS /G A GUIDE TO COMPLETE WORK SHOWN HEREIN AND INCLUDE IN THEIR BUDGET COSTS FOR MINOR FIELD DEVIATIONS. WHERE MAJOR DEVIATIONS ARE EXPOSED (WHERE THE INTENT OF WORK CANNOT BE COMPLETED AS SHOWN), CONTRACTOR SHALL STOP WORK IN THE EFFECTED AREA AND NOTIFY ENGINEER OF DISCREPANCY. 23. COORDINATE DELIVERY AND STORAGE OF MATERIALS WITH THE OWNER. 24. FURNISH ALL CERTIFICATES OF APPROVALS BY THE PLUMBING INSPECTOR AND BOARD OF HEALTH. 25. MAINTAIN A MINIMUM CLEARANCE OF THREE FEET IN FRONT OF ELECTRICAL PANELS AND ONE FOOT EITHER SIDE WITH PIPE. 26. INCLUDE IN BID, ALL LICENSE, PERMIT, INSPECTION AND OTHER FEES REQUIRED TO COMPLETE WORK. 27. DURING CONSTRUCTION PROCEDURES, THE ENTIRE WORK AREA SHALL BE CLEAN OF ALL DUST, DIRT AND OTHER DEBRIS BEFORE APPLICATION OF ANY NEW MATERIALS. 28. CONTRACTOR SHALL PROVIDE AND INSTALL NAIL Pt.ATES WHERE PIPING PASSES THROUGH STUD(S) WITHIN 2' OF NAILING SURFACE TO PROTECT PIPE FROM NAILS OR DRYWALL SCREWS. • - REVISIONS BID SET © 2021 Midwt-st(•m Engineers. Inc 802 W�sl Broadwn, Sl!"Cet P.O. Bo., 295 Looioot�c. lm!i,ma -17553 DATE SEPT, 2021 DESIGN AF,B. DRAWN C.N.M. Q.C. CHECK R,D,W, PROJECT NUMBER 20'15078-01 P1 .14 37 OF 11 4 FlLE NUMBER 42035 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2