Midwestern Engineers, Inc. Plan Preview

' I I ----------+HH- -- = = f f /; 111 3" OVERFLOW LINE � _, I - / // 2 I I - / 2" I � "'-- ALUMINUM CHLORIDE 2,200 GALLON CONICAL BOTTOM BULK STORAGE TANK � �" DISCHARGE CONNECTION =JI; FILL LINE ' u 1j"¢,42"H ALUM b ACCESS LADDER . . ,n--,1 -1:� - -�� ----�------YI •--� I __, I = 111 I_,,....._] 111 ,.\ . ,. . ., . ' I SECTION 17 >-------- SCALE: 1/2" - 1'-0" 18 19 M1.15 M1.15 4" VENT LINE 4 1r¢x42"H ALUM. ACCESS LADDER r ' 3" DISCHARGE 17 M1 .15 18"x18"x12" SUMP PIT w/ ALUM GRATING (SEE DETAIL, SHT. M1.16) / / ' / I 3" OVERFLOW LINE 6" MUD VALVE BULK STORAGE TANK CONTAINMENT AREA FIN. FLR. ELEV. 434.50' A I I I \ I \ 2" FILL LINE I 111 1 11 II II 11111 -------------- ----- --- - JIIJII - - - - - - - - - =::-,0/; ===== _}_ = _\_ =====- - --------------- --------------- -- �- 3 - I --- \ --- / \ I \ - -=:::-7 (2) RUNS OF 3/4" CHEMICAL FEED PIPE IN 3" PVC CONDUIT (1 IN SERVICE, 1 SPARE) TO NEW MANHOLE No. 2 (CHEMICAL FEED MANHOLE) l " INLET CONNECTION - ----------- - --- -�-- - ----- - -- ----------- - - - 3" CONDUIT CHEMICAL FEED ROOM F.F. EL. 438.50' - CHEMICAL FEED ROOM - PIPING PLAN SCALE: 1/2" - 1'-0" ,. - • J / / / / / / / ..I j" OUTLET CONNECTION CHEMICAL FEED EQUIPMENT SCHEDULE SYMBOL DESCRIPTION FILL LINE, 2" HOSE ADAPTER w/QUICK DISCONNECT 2 2,200 GALLON CONICAL BOTTOM BULK STORAGE TANK, "ASSMANN CORP." ICB 2200, 96"¢ x 105"H w/lCS 2200 CONICAL BOTTOM TANK STANO 3 POLY-ALUMINUM CHLORIDE (PAC), 2 PUMP CHEMICAL FEED SKID, SEE SPEC. 4 EMERGENCY EYE WASH & DELUGE SHOWER NOTE: ALL EQUIPMENT SUBMITTALS OTHER THAN BRAND NAME LISTED IN SCHEDULES OR REFERENCED ON PLANS SHALL BE ENGINEER PRE-APPROVED EQUAL Fl PIPE SUPPORT BRACKET 2" BALL VALVE 2" QUICK DISCONNECT w/CAP -·- ,, .. ' .. ) ) I I I ) I, 4" VENT TO EXTEND THRU ROOF 2 . ) I ' I ) I I l I i . . ' . .. SECTION 1 8 >--- S - CA _ L _ E _ : - 1/ - 2 - .. --- 1 -, - - 0 -,, -�v 'r;J .: 1 �'\ A //ll l�Wi\ 1 / r j l , ' y ci j , . '., .. - ": . .0J ;a; ' � � - - ,.;_1/,, -- � - - - �- - F ' , - - - . ' .. . . ·_. . _.,.· ' 1 XXXX XXXXYY, -� T I I - , � / ' r ·½V/ X - I - 12,. XJXXXf YYXXXX I I I I I I J_, C JJXX x:x\1 1 1 : yyyy ,()i_,;,),!, - r -. -- t OUTLET ' / CONNECTION ,/ - - 1 1j"¢,42"H ALUM. ACCESS LADDER F' ·� r� __ I I -� I / l " INLET -- -CONNECTION w - / � I I� 7 - I . I . . ,:, .. . . ' ' •• .. . ' . , .• ,. - .. . ··- . ' ' - .. - ' ' - ·--�� �- �- - - . � - - . - ' -- .. ' - - . " ' -� .,, ... ,.... :.r r,.;.'�;-, ,.J----,r"S ,,. SECTION 19 >-------- SCALE: 1/2" � 1'-0" NOTES: 1. 1" BRAIDED PVC CHEMICAL FEED TUBING SHALL HAVE POLYESTER BRAID. 2 NO STEEL PRODUCTS SHALL BE USED IN THE CHEMICAL FEED SYSTEM LINES, TANKS, PUMPS, OR APPURTENANCES FOR ANY PART THEREOF WHICH COMES INTO CONTACT WITH THE CHEMICAL BEING FED. ALL SUCH COMPONENTS SHALL BE PVC/PE. 3. 1" BRAIDED PVC CHEMICAL FEED TUBING SHALL BE CONTINUOUS IN THE UNDERGROUND PORTION OF THE 3'' CONDUIT. NO SPLICES/CONNECTIONS SHALL BE PLACED IN THE BURIED PORTION OF THE TUBING. 4. J" CONDUIT SHALL BE WATER TIGHT. 5. INSTALL SCH. 80 PVC LB CONDUIT BODIES OR PULL BOXES AT ALL "NON-BURIED" BENDS, SIZED PER NEC. 6. SELF REGULATING HEAT TAPE SHALL BE WRAPPED AND SECURED AROUND THE CHEMICAL FEED TUBING WITHIN THE 3'' CARRIER PIPE TO PREVENT FREEZING, SEE SPECIFICATIONS ANO ELECTRICAL SHEET FOR MORE INFORMATION. INSTALL ALL POWER/CONTROL PER MANUFACTURER'S RECOMMENDATIONS. CHEMICAL FEED SYSTEM NOTES: 1. ALL CHEMICAL FEED SYSTEM COMPONENTS AS NOTED IN THE SCHEDULES OR REFERENCED ON PLANS OR IN THE SPECS SHALL BE ENGINEER PRE-APPROVED EQUAL. 2. INSTALLATION OF CHEMICAL FEED EQUIPMENT, PIPING AND APPURTENANCES SHALL BE IN ACCORDANCE TO THE CURRENT FEDERAL ANO STATE REGULATIONS. 3. IT IS THE CONTRACTORS RESPONSIBILITY TO PROVIDE ALL APPURTENANCES NECESSARY TO COMPLETELY INSTALL ANO MAKE FULLY OPERATIONAL THE CHEMICAL FEED EQUIPMENT AND/OR SYSTEM. 4. SUPPORT ALL EQUIPMENT, PIPING & TUBING CEILING HANGERS, AND/OR WALL STRAPS, A MANUFACTURER'S RECOMMENDATIONS. USING APPROPRIATE FLOOR STANDS, MIN 4'-0" 0.C OR PER EQUIPMENT 5. ALL BALL ANO CHECK VALVES SHALL BE SCH. 80 PVC. 6. ALL CONNECTIONS TO CHEMICAL STORAGE TANKS SHALL BE FLEXIBLE PIPE. ALL MATERIAL IN CONTACT WITH THE CHEMICAL SHALL BE PVC/PE. 7. ALL CHEMICAL FEED LINES SHALL BE HOPE/SDR-9/CTS OR SCH. 80 MATERIAL COMPATIBLE w/ THE CHEMICAL BEING CARRIED w/ A 200 PSI WORKING PRESSURE. 8. NO STEEL COMPONENTS SHALL BE USED WHICH COMES INTO CONTACT w/ THE CHEMICAL. 9. J"1" PVC CHEMICAL FEED TUBING SHALL HAVE POLYESTER BRAID. 10. ALL ELECTRONICS ANO CONTROLS FOR PUMPS ANO LEAK DETECTION OUTSIDE OF CONTAINMENT AREA (ABOVE LIQUID SPILL AREA). TO BE LOCATED 11. IDENTIFICATION LABELS/TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS ANO EQUIPMENT AND SHALL INCLUDE LABEL ITEM NAME ANO NUMBER, ETC., CONTRACTOR TO COORDINATE NECESSARY INFORMATION WITH THE OWNER. 14. ALL PIPING SHALL BE LABELED w/CONTENT NAME, PHYSICAL STATE, PRESSURE LEVEL & FLOW DIRECTION ARROWS OF LIQUID OR GAS. CONTRACTOR SHALL APPROPRIATELY LABEL THE CHEMICAL FEED LINES, THE CHEMICAL FILL LINES AND THE TANK VENT LINE. 15. PIPE LABEL SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES ANO VALVES ANO SHALL INCLUDE FLOW DIRECTION OF CONTENTS. 16. CONTRACTOR TO PROVIDE REQUIRED CHEMICAL HANDLING SAFETY EQUIPMENT PER CHEMICAL USED IN CORROSION-RESISTANT WALL CASE. EQUIPMENT SHALL INCLUDE BUT IS NOT LIMITED TO: CHEMICALLY RESISTANT PROTECTIVE GLOVES MADE FROM PVC, NEOPRENE, NITRILE, VINYL OR PVC/NBR; CHEMICAL GOGGLES, SAFETY GLASSES OR FACE MASK; CHEMICALLY RESISTANT APRON; AND NIOSH-APPROVEO AIR-PURIFYING OR SUPPLIED-AIR RESPIRATOR. 17 IT IS THE OWNER'S RESPONSIBILITY TO SUPPLY THE CHEMICAL FOR INITIAL PLANT START-UP. PIPE LABEL REQUIREMENTS PIPE DIAMETER MIN. LABEL SIZE MIN. LETTER HEIGHT 0.75" TD 1.25" 1" X 8" 0.5'' 1.25" TO 2.5" 1" X 8" 0.75" 2.5" TO 8" 2" X 12" 1.25" NEW CHEMICAL FEED BUILDING - CHEMICAL FEED PLAN I REVISIONS � 2021 /llidwc,1crn Engin�ers. Inc. 802 We,! Brnad1»ay Strt,el P.O. [!()x 29� Loo�ool<',·. h1dia,i:a 47553 DATE FEB. 2021 DESIGN C.W.R. DRAWN Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 M1 .1 5 38 OF 11 4 FILE NUMBER 42034 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2