Midwestern Engineers, Inc. Plan Preview

o' I : �' �� ,l� "" � ' N- 00 N� � �� �� -w '- ,� � cc z� "' Q �d tj w� 5q � "0 � 00 . � 0 N � so , . . ._ r----------48.7 5----------<3. 5 00 3 0.00 6.00 L'-=====1=======1=====-1------+1- �11.eso PLAN VIEW 3.00 BLACK UV PROTECTED PP � --- ---111 STAND 112" 0.0. PVC TUBING VENT TO TANK 2000ml PVC ----/J'.__ - - J CALIBRATION COLUMN SIGMA 1 SERIES METERING PUMP 2TYP. PUMP MODEL: 12035 PJT 11.1 GPH@ 145 PSIG 2-112" 316SST PRESSURE GAUGE WITHCPVC/PTFE ISOLATOR (0-160PSIG) 1/2" PVCNITON NPT BALL VALVE PRODUCT OUTLET :f--il:!l----lf--+--112" PVCNITON NPT BALL VALVE FLUSH PORT 2TYP. 1/2" PVC PRESSURE RELIEF VALVE (ADJUSTABLE 0-15 0PSIG) 2TYP. 112''PVCNITON WYE-STRAINER �? ""' "'- :/ c:: :_____ 112" PVCNITON NPT FRONT VIEW ABS PLASTIC SHOWER HEAO ANO ELBOW 60.00 55.00 8.000 0 CHEMICAL FEED SKID STN. STL. ACTUATING ARM 1" CHROME PLATED BRASS STAY-OPEN BALL VALVE NOT TO SCALE ISOMETRIC VIEW SIDE VIEW o. 5 BARS - GROUTED -------- -a- -- I--- I 1¼" NPT FEMALE INLET 8" C.M.U. WALL w/N VERT. @ 48" o.c. IN CORES w/ HORZ. R 16" o.c. VERT. EINF @ ' 0, "' ' .. "' 0, N _,,,y- STN. STL. �-ccJ/ ___ j I PULL ROO 10" GALV. STL. PIPE---! AND FITTINGS SPRAY HEAOS 6!," I-+\+- ABS PLASTIC BOWL SHOWER HANDLE CAST ALUM. FLOOR FLG. 11½"• 1- 1/4" NPT FEMALE INLET (CAPPED) ½" IPS CHROME PLATED BRASS STAY-OPEN BALL VALVE 1Y4" NPT FEMALE OUTLET ANGLE DRAIN TOWARDS FLOOR GRAIN T/SLAB $ELEV. 438.50' 12" POURED CONG. WALL w/No. 5 BARS @ 12" o.c.e.w.e.f. ,� ' . - "'' - £ - r' ' CONSTRUCTION JOINT CHLOROPRENE RUBS WATERSTOP, TYP. w/ --; ' ER �� . ¥ � -;;i� �� � T SLAB -<. ELEV. 434.5D' . j • ' 0 < I " s::: T SLAB a ELEV. 433.50' " - " d • " • • ·"• r-.... " d " . ' " ' • d " " 2 EMERGENCY EYEWASH DETAIL 3 SUMP PIT DETAIL NOT TO SCALE " BALL VALVE PRODUCT INLET � VALVE WRENCH = =· ALUMINUM GRATING 1 , 6" 1j" X 1j" X ¾" S. s. C. w/No. 5 BARS @ 12" o.c.e.w.t.&b. ANGLE SLAB ;1 / 12" POURED CON T/SLAB ELEV 434.50' " ' 0 I d • • r.l' . " ' • 1/,;,- L d " • " - CONTAINMENT WALL SCALE: 3/4" = 1'-0" f- I 0 w I � <{ > 0 a, rt-1>::.1-+r+---+-'-lf----t,+----, I� PIPING SCHEMATIC , NOTES: 1. ALL PIPING AND FITT INGS SHALL BE 112" SCH. 80 PVC SOCKET WELD WITH VITON SEALS UNLESS OTHERWISE REQUIRED BY COMPONENTS. 2.ALL DIMENSIONSARE IN INCHESAND ARE SHOWN FOR REFERENCE ONLY PIPE LABEL REQUIREMENTS PIPE DIAMETER MIN. LABEL SIZE MIN. LETTER HEIGHT 0.75" TO 1.25" 1" X 8" o . 5 '' 1.25" TO 2.5" 1" X 8" 0.75" 2.5" TO 8" 2" X 12" 1.25" NOTES: 180 0 I f- I I 0 >- w 0 I 0 (D 96" DIA. z <{ a, f- "' t- 0 � w ' z '° 0 NU 9" FLAT 19" ACCESS 1. 41" X 48" DOME FLAT 2. 1Q" X 1O" DOME FLATS ( 3 PLACES ) 3. 9" DIA. CONE TIP FLAT 4. MANWAY W/ HINGED COVER 270 ° 0 A-A C E D MK A B C D E F G H CHEMICAL FEED SYSTEM NOTES: 1. ALL CHEMICAL FEED SYSTEM COMPONENTS AS NOTEO IN THE SCHEDULES OR REFERENCED ON PLANS OR IN THE SPECS SHALL BE ENGINEER PRE-APPROVED EQUAL. 2. INSTALLATION OF CHEMICAL FEEO EQUIPMENT, PIPING AND APPURTENANCES SHALL BE IN ACCORDANCE TO THE CURRENT FEDERAL AND STATE REGULATIONS. 3. IT IS THE CONTRACTORS RESPONSIBILITY TO PROVIDE ALL APPURTENANCES NECESSARY TO COMPLETELY INSTALL AND MAKE FULLY OPERATIONAL THE CHEMICAL FEED EQUIPMENT AND/OR SYSTEM. 4. SUPPORT ALL EQUIPMENT, PIPING & TUBING USING APPROPRIATE FLOOR STANDS , CEILING HANGERS, AND/OR WALL STRAPS, A MIN. 4'-0" O.C. OR PER EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. 5. ALL BALL AND CHECK VALVES SHALL BE SCH. 80 PVC. 6. ALL CONNECTIONS TO CHEMICAL STORAGE TANKS SHALL BE FLEXIBLE PIPE. ALL MATERIAL IN CONTACT WITH THE CHEMICAL SHALL BE PVC/PE. 7. ALL CHEMICAL FEEO LINES SHALL BE HDPE/SDR-9/CTS OR SCH. 80 MATERIAL COMPATIBLE w/ THE CHEMICAL BEING CARRIED w/ A 200 PSI WORKING PRESSURE. 8. NO STEEL COMPONENTS SHALL BE USED WHICH COMES INTO CONTACT w/ THE CHEMICAL. 9. CHEMICAL SUPPLY TUBING FROM STORAGE TANKS TO THE FLOOR MOUNTED FEED SYSTEM SHALL BE BRAID REINFORCED CLEAR PVC, SIZE PER PLAN. 1" PVC CHEMICAL FEED TUBING SHALL HAVE POLYESTER BRAID. 10. CHEMICAL FEED TUBING FROM FLOOR MOUNTED FEEO SYSTEM TO THE POINT OF DISCHARGE SHALL BE CLEAR PVC TUBING. CONDUIT/CARRIER FOR FEED TUBING SHALL BE HOPE SDR-9. 11 ALL ELECTRONICS ANO CONTROLS FOR PUMPS ANO LEAK DETECTION TO BE LOCATED OUTSIDE OF CONTAINMENT AREA (ABOVE LIQUID SPILL AREA). 12. IOENTIFICATION LABELS/TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS AND EQUIPMENT AND SHALL INCLUDE LABEL ITEM NAME ANO NUMBER, ETC., CONTRACTOR TO COORDINATE NECESSARY INFORMATION WITH THE OWNER. 14. ALL PIPING SHALL BE LABELED w/CONTENT NAME, PHYSICAL STATE, PRESSURE LEVEL & FLOW DIRECTION ARROWS OF LIQUIO OR GAS. CONTRACTOR SHALL APPROPRIATELY LABEL THE CHEMICAL FEED LINES, THE CHEMICAL FILL LINES AND THE TANK VENT LINE. 15. PIPE LABEL SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS ANO WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. 16. CONTRACTOR TO PROVIDE REQUIRED CHEMICAL HANDLING SAFETY EQUIPMENT PER CHEMICAL USED IN CORROSION-RESISTANT WALL CASE. EQUIPMENT SHALL INCLUDE BUT IS NOT LIMITED TO: CHEMICALLY RESISTANT PROTECTIVE GLOVES MADE FROM PVC, NEOPRENE, NITRILE, VINYL OR PVC/NBR: CHEMICAL GOGGLES, SAFETY GLASSES OR FACE MASK; CHEMICALLY RESISTANT APRON; AND NIOSH-APPROVED AIR-PURIFYING OR SUPPLIED-AIR RESPIRATOR. 17. IT IS THE OWNER'S RESPONSIBILITY TO SUPPLY THE CHEMICAL FOR INITIAL PLANT START-UP. QTY SIZE 1 - 1 - 6 - 6 - 6 - 3 - 3 - 1 - A-A 8 C E D ACCESSORIES DESCRIPTION FULL PAN: FORMED FROM 12 GA. SHEET STEEL ROLLED TO A 30" ANGLE WITH 96" DIA. TOP AND 9" DIA. BOTTOM OPENING SUPPORT RING: 1 1/4" SCH 80 BLACK PIPE ROLLED TO AN 98" O.D. TOP SUPPORT: 3" X 4.1 "C'' CHANNEL 48 1/2" LONG BOTTOM FOOT PAD; 3" X 4.1 "C" CHANNEL 41 1/4" LONG OUTER LEGS: 2" X 2" X 3/16" BOX TUBING CUT TO A 30' ANGLE 35 1 /8" LONG SIDE MIDDLE LEGS: 2" X 2" X 3/16" BOX TUBING CUT TO A 30' ANGLE 25 3/4" LONG SIDE INNER LEGS: 2" X 2" X 3/16" BOX TUBING CUT TO A 30' BOTTOM RING: E DETAIL A 4x SCALE D F ANGLE 16 318" LONG SIDE 1 1/2" X 1 1/2" X 1/4" ANGLE ROLLED TO 12" LEG OUT SEE DETAIL A E D D SECTION A-A ICS 2,200 GALLON CONICAL 0 ICB 2,200 GALLON CONICAL BOTTOM BULK STORAGE TANK NOT TO SCALE 0 BOTTOM TANK STAND 5 ------NOT TO SCALE NEW CHEMICAL FEED BUILDING - BUILDING SECTIONS REVISIONS 08-27-21 C 2021 Midwc,1cm Enginec•,-s. In�. 302 \W,L Bro:odw:,� su-,,�1 P.O. Bo, 295 Loogoot,,c. lmfona 47553 DATE FEB. 2021 DESIGN C.W.R. DRAWN Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 M1 .16 39 OF 114 FILE NUMBER 42033 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2