Midwestern Engineers, Inc. Plan Preview

D\ - -- i \!i. I - ' � C � • Cl � � w 0 o' = �' 0 ".,,, i' � "' <I" �w •c M- NO 0"' N ,_ �� - .� �I" -w Qo "" ., zo <u , ., "' - 5� �u "' - SN 55 , . <c 8" JET MIXING PUMP SUCTION LINE INSTALL NEW JET MIXING NOZZLE ASSEMBLY ON CONC. SUPPORT PIERS (TYP. OF 3) 3 7 07 FF 0 s" JET M1x1hG PUMP SUCTION LINE 6" JET MIXING PU DISCHARGE LINE I ... I I 6" JET MIXING PUMP DISCHARGE LINE l " I 0 �' 0 C • • .. • INTERMEDIATE LEVEL PLAN SCALE: 1/4"-1'-o" (ELEV. 432.42') 7 05 " • ,. > i � > . • �. :-i\' 7 • = • ' • • • • 8'-4" G ' . I ' ' �, tt • • • • □ ' . . ' i . 'II ··I· Jl, I i INSTALL NEW 1 Q'x8'x8' PREFABRICATED FIBERGLASS JET MIXING PUMP BUILDING T/SLAB ELEV. 432.77' H 7 05 ® 0 D □ D " I 0 ' ID I n ' ID I r-- RENOVATION NOTES: 1 INSTALL (2) TWO NEW SLUDGE PUMPS, PUMP SUPPORT PAD, PIPING, VALVES ANO APPURTENANCES. SEE SPECS FOR ADDITIONAL INFORMATION. 2. ROTATE EXISTING6" PLUG VALVE, ACTUATOR AND HANDWHEEL SO HANOWHEEL IS LOCATED ON THE FRONT LEFT SIDE OF THE PIPING. 3. REPLACE EXISTING6"x6"x6" 0.1. TEE ON SLUDGE PUMP SUCTION LINE w/NEW6"x6"x6"x6" D.I. CROSS. 4. INSTALL NEW6" PLUG VALVE AND6" D.I PUMP SUCTION LINE INTO EXISTING WET WELL No. 2 5. CONNECT NEW6"WAS. F/M LINE FROM NEW CLARIFIERS R.A.S./W.A.S. PUMP STATION TO EXISTING 4" F/M SLUDGE PUMP DISCHARGE LINE. 6. REPLACE EXISTING PLUG VALVE WITH NEW 7. INSTALL NEW PLUG VALVES IN EXISTING LINES 8. MODIFY EXISTING RAW SEWAGE PUMP DISCHARGE LINE AND INSTALL NEW 1 O" F/M TO NEW MH300A 9. RELOCATE EXISTING VALVE ACTUATOR ON EXISTING RAW SEWAGE PUMP No. 3 AS NEEDED TO INSTALL NEW SLUDGE PUMP No. 2 10. MODIFY EXISTING6" SLUDGE DRYING BEDS DRAIN LINE TO DISCHARGE INTO WET WELL No. 1 11. RENOVATE EXISTING PRIMARY SETTLING TANK EXTERIOR WALL AND FLOOR SLAB TO NEW RETAINING WALL. 12. ALL VALVE HANDWHEEL ACTUATORS TO BE INSTALLED FACING FORWARD FOR EASE OF OPERATOR ACCESS 13. ALL OVERHEAD VALVES TO BE INSTALLED WITH CHAIN OPERATED HANDWHEELS. 14. CLEAN INTERIOR STRUCTURE, REPAIR VOIDS IN WALLS ANO SLAB FROM REMOVED EQUIPMENT. SEAL AND PAINT INTERIOR WALLS AND CEILING. 15. SEE MECHANICAL & ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ON EQUIPMENT TO BE REMOVED, REPLACED OR INSTALLED. ITEM A B C D E F G H I J K L M N 0 p Q R s T u V w X y z AA 88 cc DD EE FF PIPING & EQUIPMENT SCHEDULE DESCRIPTION SLUDGE WASTE PUMP, 4" SUCTION, 4" DISCHARGE. (TYP. OF 2) SEE SPECS PUMP SETTINGS A - PUMP OFF ELEV. 415.92' B - PUMP ON ELEV. 417.42' E - HIGH WATER ALARM ELEV. 420.42' MANUAL FLOAT LEVEL REGULATORS (NOT SHOWN) RADAR SENSOR LEVEL REGULATOR (NOT SHOWN) JET MIXER PUMP, 6" SUCTION, 4" DISCHARGE, SEE SPECS JET MIXER NOZZLE ASSEMBLY (TYP OF 3) SEE SPECS. 1O" 0.1. 45' BEND (M.J. OR FLG) 8" D.I. go· BEND (M.J. OR FLG) 8" D.I. 45' BEND (M.J. OR FLG) 8"x6" D.I. REDUCER (M.J. OR FLG) 8" " TIDEFLEX" FLG. CHECK VALVE, (OR APPROVED EQUAL) 6" D.I. go· BEND (M.J. OR FLG) 6"x4" D.I. REDUCING 90- BEND (M.J. OR FLG) 6" 0.1. 45· BEND (M.J. OR FLG) 6"x6"x6"x6" D.I. CROSS 6"x6"x6" TRUE ''y'' 6"x4" 0.1. REDUCER (M.J. OR FLG) 6" D.I. FLARE FITTING 5" CHECK VALVE 5" PLUG VALVE w/HAND OR CHAIN WHEEL ACTUATOR 4" 0.1. 90- BEND (M.J. OR FLG) 4"x4"x4" 0.1. TEE 4" CHECK VALVE 4" PLUG VALVE w/HANDWHEEL OR CHAIN WHEEL ACTUATOR AIR/VACUUM VALVE w/DRAIN LINE TO WET WELL LINK SEAL WALL SLEEVE EBBA IRON MEGA-LUG, SIZE PER MAIN BLIND FLANGE, SIZE PER MAIN M.J. CAP OR PLUG, SIZE PER MAIN MJ X MJ FOSTER ADAPTER, SIZE PER MAIN P.V.C. DRAIN LINE w/BACKWASH CHECK VALVE PIPE SUPPORT STANDS, INSTALL PER MFGR'S RECOMMENDATIONS 8" 0.1. 22.5' BEND EXISTING CONTROL BUILDING / ANAEROBIC DIGESTER - RENOVATION PLAN I REVISIONS 09-14-21 (tl 2021 )l.!idv.�st�ro Engill<.-cr.,. inc. 802 We,\ Broadway Str,:�1 P.O. IJox 295 Luo�OOll'�. lndi,,na 47553 DATE FEB. 2021 DESIGN CW.R. DRAWN S.L.H. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 7.06 78 OF 114 Fll£ NUMBER 41994 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2