INSTALL NEW CONC. 1 '-8" CAP ON TOP OF r 1. 1. EXISTING WALL (3) No. 4 BARS CONT., T WALL No. 4 BARS @ 12" o.c.�-' i�i; i � "" = "' � ;,-:- <D _,,_..,,- <D r----t- ---'- v /- A -'- R '-' I E O! S �-----,� No. 4 DOWELS @ 12" O.C., --+..j MIN 12" EMBEDMENT CONTRACTOR TO APPLY RUBBED FINISH TO EXISTING EXPOSED CONC. WALLS z ::, Cf> ' w <D - 1:;i ;,,> l I _[ EL. z SAW CUT EXISTING CONC. � SETTLING TANK WALL TO ' N DEVELOP NEW RETAINING st WALL EX I ST I NG GRADE VAR I ES EL. 439 50'-434 0' EX I STING GRADE VARIES EL. 434.00' -432.42' T/EX I STING SLAB $ VAR I ES (F.V.) EL. 430.59'-430.76' SAW CUT EXISTING CONC. SETTLING TANK FLOOR SLAB TO PROVIDE FOOTING FOR NEW RETAINING WALL 1 NEW RETAINING WALL DETAIL SCALE: 1/2" ~ 1'-0" ------ H.M. INSULATED --4 DOOR w/WIRE 0 I c-- GLASS 3'-0" I CD DOOR TYPE SCALE: j"~1'-o" NOTE: 5¾" T H.M. FRAME 0 I c-- ALUMINUM WINDOW -2."II 3• -0 " �.!'c� FRAME TYPE SCALE: f~1'-o" CONTRACTOR TO FIELD VERIFY ALL DOOR AND WINDOW OPENING SIZES PRIOR TO BEGINNING CONSTRUCTION Cl) 0 0 I "" kl CD WINDOW TYPE SCALE: f�1'-0" 7.03 IRESTROOMI 'i 0 ,- ! 10:D & ______j�----�==;- ____ &' 0 0 0 --------- I ----q I '-----y I I I 4 - 1�- EX 6" SUPERNATANT DRAW-OFF i1- 1 I I I I 1 ,--· -�- I i �-�'�] _j I I lrll------JF p-l I I NEW ELECTRICAL ROOM F.F.EL. 442.42' _JI I I I - -' EXISTING LAB F.F.EL. 442.42' 0 0 I 5 i I I f----� --i 5 WET WELL T/SLAB - ELEV. 440.27' I i I I I I 6 \--ll- - 5 I I J I I I I I ,--L---';--j�L_J I __ ,__J I \ \ \ MAIN LEVEL - PLAN VIEW SCALE: 1/4"~1'-Q" LOADING DOCK T/SLAB ELEV. 442.42' (ELEV. 442.42') SEE STAIR ANO LANDING DETAILS ON SHEET 7.11 MAIN LEVEL RENOVATION: 1. REPLACE EXISTING DOOR, FRAME AND HARDWARE WITH NEW 2. REPLACE EXISTING ALUMINUM WINDOW WITH NEW 3. EXISTING STEPS, LANDING ANO HANDRAILS TO BE RENOVATED FOR NEW LANDING AND WALKWAY 4. REMOVE AND REPLACE EXISTING 6" ANAEROBIC DIGESTER SUPERNATANT DRAW-OFF PLUG VALVE ANO APPURTENANCES WITH NEW. 5. CLEAN INTERIOR STRUCTURE, REPAIR VOIDS IN WALLS AND SLAB FROM REMOVED EQUIPMENT. SEAL AND PAINT INTERIOR WALLS. 6. REPAIR CONC. SLABS TO MATCH EXISTING. 7. RENOVATE EXISTING PRIMARY SETTLING TANK EXTERIOR WALL AND FLOOR SLAB TO NEW RETAINING WALL. 8. SEE MECHANICAL & ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ON EQUIPMENT TO BE REMOVED, REPLACED OR INSTALLED. 26'-4" 26'-o " 11-=:_______ 1--=:____:::_--J-_----\--_____ __j-�. ] 7 INSTALL NEW CONC. CAP ON NEW RETAINING WALL EXISTING CONTROL BUILDING / ANAEROBIC DIGESTER - RENOVATION PLAN REVISIONS 09-14-21 � 2021 Midwe,tern En�incers. Inc. 802 Wc,1 Bro,,dwa: Str-cct P.O. l!ox 29S Looi;,xm'<:. Indi,ma -1-7553 DATE FEB. 2021 DESIGN C.W.R. DRAWN S.L.H. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 7.08 80 OF 114 FIL£ NUMBER 41992 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2