Midwestern Engineers, Inc. Plan Preview

0 0 N' �' :, I = 0 " ' � s j " ,SW 0 I;; �" N, NO N� o, NO �� ,� !:. 0 �� .w •t;; 0 - OJ �\ .Q 0 ' 01\ � SU > � oz • g ;; 1 • ' - "� ' " u� , � LN 0 • c:. 5£ , . � �" • � SLUDGE HEATER TO REMAIN NATURAL GAS SUPPLY TO REMAIN 1---1" PILOT LINE TO REMAIN f-f---2" METHANE LINE TO REMAIN SLUDGE HEATER DEMOLITION SCHEMATIC NOT TO SCALE 0-+--- EXISTING 14" ALUMINUM DUCT REMOVE FLEXIBLE CONNECTION (TYP.) REMOVE IN-LINE EXHAUST FAN AND ACCESS DOOR COMPLETE REMOVE ANGLE---..fl SUPPORT STAND INTERMEDIATE FLOOR7 I EXISTING 14"ALUMINUM DUCT � REPLACE WITH 14"¢ ALUMINUM >----DUCT, CONNECT TO EXISTING TOP AND BOTTOM EXHAUST FAN DEMOLITION DETAIL NOT TO SCALE 4 CD Lr\ 1 I" v � I I �� f----'- : -t- : - ra= I I � I 2 7 5 _J 0 6 f� ,. 'f -,; ' ', ' 1 < NATURAL GAS SUPPLY TO REMAIN INTERMEDIATE LEVEL HVAC AND PLUMBING DEMOLITION PLAN EXISTING SLUDGE HEATER r 4"x2" FLANGED REDUCER MODEL 1021 ACCUMULATOR WITH DRIP TRAP MODEL 226 PILOT LINE FLAME CELL > TO FLOOR DRAIN � 2" EXISTING GAS TRAIN EXISTING SHUTOFF VALVE �J 0---EXISTING DIGESTER I ) � CONNECTION ffio 4" ! FLAME CHECK ;� 1" ' 2" MODEL 94 PRESSURE RELIEF FLAME TRAP �- MODEL 466 DRIP TRt\P 1---EXISTING 1" PILOT LINE TO WASTE I GAS BURNER t•-+----EXISTING 2" ' METHANE LINE TO WASTE GAS BURNER + f---;,,:,,,::!l:;;�� ;:;- {��-- UPBLAST CENTRIFUGAL ,�----, h EXHAUST FAN CONTRACTOR SHALL PROVIDE ROOF CURB ROOF ,/- )<__, /. LIQUID TIGHT--. = FLEXIBLE CONDUIT " "' ' , EXISTING 1- 4"¢ / � -� EXHAUST DUCT SLUDGE HEATER PIPING SCHEMATIC UPBLAST EXHAUST FAN DETAIL NOT TO SCALE MECHANICAL SCHEDULE L-2 DH-1 EF-3 PRICE - DOOR GRILLE MODEL# ATGH, 16"x24" 206 FPM @ 0.05" SP HEAVY DUTY EXTRUDED ALUMINUM HI-E DRY - DEHUMIDIFIER MODEL 100 106 PINTS/DAY @ BOT, 60%RH 120V-1¢, 6.6A TERMINATE DRAIN OVER SUMP PUMP GREENHECK - UPBLAST EXHAUST FAN MODEL# CUE-100-A 1010 CFM @ 0.69"' SP, J:\ HP, 120V-1; w/ INTEGRAL DISCONNECT BACKDRAFT DAMPER, BIRDSCREEN MANUFACTURER RECOMMENDED ROOF CURB EUH-1 MARKEL - ELECTRIC UNIT HEATER MODEL# P3PUH10CA1 34,100 BTUH, 575 CFM 480V-3¢, 12.1 A THERMOSTAT, DISCONNECT, CEILING BRACKET AH-3 TRANE - 1.5 TON MINI-SPLIT SYSTEM MODEL# TPKADA0181LAOOA 18,000 BTUH WALL MOUNTED INDOOR UNIT 4 SPEED AUTO FAN, 265/310/385/455 CFM CU-3 TRANE - 1.5 TON MINI-SPLIT SYSTEM MODEL# TRU2A0181KA708A 208V-1 ;, 11.0 A REMOTE CONTROLLER, WIND BAFFLE DISCONNECT SWITCH, CONDENSATE PUMP DEMOLITION PLAN NOTES 0 DISCONNECT AND REMOVE IN-LINE EXHAUST FAN AND ACCESSORIES. SEE DETAIL THIS SHEET 0 0 0 ® 0 REMOVE HEATING WATER RISERS TO MAIN FLOOR. CUT AND PATCH FLOOR TO MATCH EXISTING. REMOVE DOOR LOUVER, PREP OPENING TO RECEIVE NEW LOUVER. REMOVE HEATING WATER SUPPLY AND RETURN PIPING COMPLETE. REMOVE UNIT HEATER AND ASSOCIATED HEATING WATER PIPING COMPLETE. DISCONNECT AND REMOVE HEATING WATER SUPPLY AND RETURN TO SLUDGE HEATER AND CAP. REMOVE CIRCULATION PUMP AND ASSOCIATED WIRING AND CONTROLS COMPLETE. SLUDGE HEATER, PROCESS PIPE, SLUDGE RECIRCULATION PUMP, AND EXHAUST DUCT TO REMAIN. SLUDGE HEATER GAS TRAIN TO REMAIN REMOVE SAFETY EQUIPMENT AND ASSOCIATED METHANE AND NATURAL GAS PIPING. REFER TO DEMOLITION DETAIL, THIS SHEET. 2" METHANE, 1" NATURAL GAS SUPPLY TO WASTE GAS BURNER TO REMAIN 2):\" DOMESTIC WATER, NATURAL GAS SERVICE TO REMAIN. PROPOSED GAS LATERAL BY CENTER POINT ENERGY. NOT TO SCALE PLAN NOTES 0 REPLACE DEMOLISHED FAN SECTION WITH NEW 14"¢ ALUMINUM DUCT. SEE DETAIL THIS SHEET. 0 INSTALL GRILLE INTO EXISTING DOOR OPENING. MODIFY AS REQUIRED. 0 CUT EXISTING DOOR TO INSTALL GRILLE MATCH ELEVATION ANO ALIGNMENT OF ADJACENT DOOR GRILLE. 6 f-t-+ (.D JET CLEAN FLOOR DRAIN AND ASSOCIATED UNDER FLOOR DRAINAGE PIPING TO LOWER LEVEL SUMP PUMP. CAMERA INSPECT AFTER CLEANING TO ENSURE LIKE NEW CONDITION. INSTALL MANUFACTURER FURNISHED GAS SAFETY DEVICES AND ASSOCIATED PIPE, FITTINGS AND ACCESSORIES. REFER TO DETAIL, THIS SHEET. CONNECT 2" METHANE AND 1" GAS TO EXISTING WASTE GAS BURNER SUPPLIES. 0 0 I L- rv� -2 • L EUH-1 0 4"(EXTG) 4"(EXTG) ¾... ·� ' ,,.,__ ' . ) "fil . ---,)' I "�;�;, 1 ;!��... "' ;: ¾,d I� ,· 0 6 /\(.D EUH-1 V I, /' """-, .. .. � □ . . ' "'�-_,, ,f'/ < 3 INTERMEDIATE LEVEL HVAC AND PLUMBING IMPROVEMENTS PLAN EXISTING CONTROL BUILDING / ANAEROBIC DIGESTER • REVISIONS 9/'/2071 BID SET © 2021 1'1idw�,t<·rn Engineer,. Inc. S02 We,t Broadw:iy Sm·el P.O. [lo� 295 Loo.�ootc,.,. Jndi:uw 47553 DATE SEPT. 2021 DESIGN A.F.B. DRAWN 5.1, L M. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 H?.12 84 OF 114 FILE NUMBER 41988 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2