Midwestern Engineers, Inc. Plan Preview

EXISTING CONCRETE \ WALL TO REMAIN IN PLACE "" T/EX. WALL ELEV. 429.33' EX. GRADE ,/>-,' Ec;LEV�."4�2� 8s'-_4-cc5;c,-==r-----==,---------1 • •• ' "' N . . EX. 6" F M G)____ • • . . ; 7 '- .. ·0'\ / ' ' NEW 4" D.l. FORCE MAIN 4'-0" 4" PVC INV. 432.50' 9 0 8 I "" •• 6'-0" 2 6 4 Poly Tonk ' , r "' , ., EX. 6" PVC PE;F. 9 7 2'-0" • • INSTALL NEW 4" T POURED CONC. SLAB w/6x6 W4.0xW4.0 W.W.R. OVER 6 MIL VAPOR BARRIER AND MIN. 6" COMPACTED BASE, THICKEN SLAB TO 8" AT FTR WALL, T/SLAB ELEV. 428.50' T/NEW CONC. SLAB $ ELEV. 428.50' T/EX. CONC. ELEV. 427.83' $ 4" D.I. F/M INSTALL NEW 4" T POURED CONC. SLAB w/ 6x6 W4.0xW4.0 W.W.R. OVER 6 MIL VAPOR BARRIER AND MIN. 6" COMPACTED BASE, THICKEN SLAB TO 8" AT FTR WALL, T/SLAB ELEV. 428.50' ""T/EX. CONC. WALL ELEV. 429.33' ""T/NEW CONC. SLAB ELEV. 428.50' ""T/EX. CONC. ELEV. 427.83' 8"x MIN. 30" TURNED �;;;;a� DOWN FTR. w/ No. 5 BARS @ 12" o.c.e.w. 3 Polymer Orum - 4" D.l. F/M INV. 424.67'$ Polymer Orum INSTALL NEW CLEANOUT ON EX. 6" PVC PERF. DRAIN PIPE. SEE DETAIL ON SHEET 8.02 EX. 6" PVC PERF. DRAIN PIPE INV. 424.67' (F.V) DRAIN PIPE TO NEW 4" D.l. FORCE MAIN INV. 424.00' INSTALL NEW 1" POTABLE WATER LINE FOR CHEMICAL FEED SYSTEM 4" D.I. FORCE MAIN TO CONTAINER BAG DEWATERING SYSTEM ' 0 I n ' ' 0 0 I ro N � ' I n 0 I N ' 0 I "' 0 I "" EX. TO POINT OF CONNECTION. TIE NEW 4" D.I. FORCE MAIN TO EX 6" D.I. FORCE MAIN SLUDGE FEED LINE L � D ... 8 03 ... � 3'- o " NEW 4" D.I. FORCE MAIN INV. 423.50' (F.V.) I t-1 j \ I 18'-Q" 10'-Q" ,----- ----f �---- ------------------ I I I I I f I I I ' I •• • • • -� • • • • I A I' I I • I • I ( J .I I � < � '3 • I I Ci I • • I � I " � I • � I I f; I BE ABANDONED D SECTION SCALE, 1 /2" � 1 '-0" s'-o" -----------7 I I I I I I I I I I I I 0 I �JI] � I \NEW CLEANOUT 2 I < � I I 1B � FIELD VERIFY LOAO I - - ' � -- - CENTER LOCATION I ( - • I w/ELECTRICAL I " - I CONTRACTOR PRIOR I � • I TO INSTALLATION. I I I 6 I CONNECT ALL I I ELECTRICAL WIRING, l IN CONDUIT, AS I � 1'-6" s'-6" I ' i • REQUIRED FOR FULLY I i I " FUNCTIONAL SYSTEM I I ' I I j • I I I ., I I I • • • • • • • • I '< I _, .,: I I " I G: I I I I I ' I ----------------\----------__J 0 I L _________ -,---- ,- I / ;, CONC. WALL/ Lo \INSTALL I NEW 4" T POURED CONC. SLAB REMAIN w/6x6 W4.0xW4.0 W.W.R. OVER 6 MIL NEW 4" 0.1. VAPOR BARRIER AND MIN. 6" COMPACTED FORCE MAIN NEW 1 WATER LINE INV. 424.67' (F.V.) BASE, THICKEN SLAB TO T/SLAB ELEV. 428.50' " 8 AT FTR WALL, N PLAN VIEW SCALE, 1/2" - 1'-0" ' 0 I ro� Note 1. Vertlco.\ line represents the corner of the cheMlco.l building The Flocculo.tor o.nd the PolyMer Mixer a.re 90 degrees froM ea.ch other. Note 2, Install 1' SchdBO PVC 'w'o.ter Line Atto.ched to wall of the flberglo.ss cheMlco.l building Use 1' Bro.lded Hose o.nd Co.Mlock fittings to connect Port-A-Poly to the PVC \r/o.terllne Blue River Technologies Port-A-Poly w/Blue White A2 Series Pump Neat Polymer Suction Hose w/Borrel Wand I I I I I I I I I I Polymer Drum PAK 524 Spill D&::k Note, 2 Floor Level Note1 1 E SECTION SCALE, 1/2" - 1'-0" PIPING & EQUIPMENT SCHEDULE ITEM DESCRIPTION 1 12'-0"Lx1O'-0''wx7'-6"H MODULAR FIBERGLASS COMPOSITE BUILDING, SEE SPECS. 2 SLUDGE/FLOCCULANT MIXER w/4" SCH 80 FLANGED END CONNECTIONS 3 POLYMER METERING PUMP ON S.S. SHELF 4 POLYMER SOLUTION HOSE STORAGE COMPARTMENT 5 (2) 55 GAL DRUMS, POLYMER, ON 2 DRUM CONTAINMENT PALLET w/RAMP 6 4" D.l. 900 BEND 7 SLIP ON GASKE . TED 4" 150# CAST IRON FLANGE 8 4" CHECK VALVE 9 4" PLUG VALVE 10 1" CHECK VALVE 1 1 POLYMER INJECTION QUILL/POINT 12 2" POLYPRO BALL VALVE FOR FLOC SAMPLING 13 PIPE SUPPORT STAND 4" Sludge/Flocculant Mixer w/4" Schd80 Flanged end connec. / / / / / ..... ..... ..... ..... ..... 24' HIGH IJAfER SG.EN □ l!I VALVE FLO\/ REG.IL.ATOR (Jlf'l!Llo/AL) NOTE, IT IS THE CONTRACTOR'S RESPONSIBILl1Y TO SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT, PIPING, VALVES AND APPURTENANCES FOR A FULLY OPERATIONAL CONTAINER BAG SLUDGE DEWATERING SYSTEM, INCLUDING THE CHEMICAL FEED SYSTEM AND THE SLUDGE LIFT STATION. INSTALLATION SHALL BE IN ACCORDANCE TO THE MANUFACTURER'S RECOMMENDATIONS. c· Ill"- HAN!l.E SOLUTJO"i OUT � Poly Tank WATER IN H "' H" __,..,� 1�0--0--� 1\i====='='='==='�,JI l '" NPT Out to Dewatering Pod Incoming Water Line Install 1" Brass Shutoff Valve In from Sludge pumps �._.., \lhite � Po""'tc,!t,c P,...,p APPROX, J4' DEEP ,'.:.PPR□X, \.IT 57 LBS .... / E ' 11,,, � , 8 03 0 CHEMICAL FEED DETAIL 3----- NOT TO SCALE 0 CHEMICAL FEED PUMP DETAIL 4f-------NOT TO SCALE "" T,.'EX. WA LL ELEV. 429.33' EX. 6" 0.1. F M ,,.. INV. 425. oo· (F.v.) POINT OF CONNECTION. TIE NEW 4" D.I. FORCE MAIN TO EX. 6" D.l. SLUDGE FEED LINE ' • • INSTALL 4" PLUG VALVE - NEW 4" 0.1. FORCE MAIN F SECTION SCALE, 1/2" � 1'-0" INSTALL 4" PLUG VALVE (NORMALLY CLOSED) INSTALL 4" PLUG VALVE (NORMALLY OPEN) ,:r---c:-=-- ���---c;:-:��.,.,.......----- - �� --.,......_' --,,.j_� ,·J ,,, � -- - - NEW 4" D.I. FORCE MAIN 4"x4"x4" D.I. TEE T/WALL ELEV. 429.33'$ T/EX. CONC. $ ELEV. 427.83' 4" D.l. F/M INV. 424.00' $ NEW CONTAINER BAG SLUDGE DEWATERING SYSTEM AND POLYMER FEED BUILDING ;; "B .B ·a: • .c- uex: ,:,i I REVISIONS © 2021 :: ;;; 1, " • �liUw�st.,rn Engineer,. Inc. .�02 \Ve-,! Broadway Strc�I 1'.0 Box J:'l5 Luo;;c>wlt"<'. lmlia,ia 47553 DATE FEB. 2021 DESIGN C.W.R. DRAWN M.M.C. Q.C. CHECK R.D.W. PROJECT NUMBER 2015078-01 8.03 89 OF 114 I FILE NUMBER _ 41983 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2