Midwestern Engineers, Inc. Plan Preview
7 / ' / - I I ) / , , o / I/ :.r-fli-•-•-•_L 0 I ----·-•-•--c:,-•-•-•-•-·-·-•-•-• + I 0 I <O SPECIAL NOTES SN1 EXISTING WATER MAIN TO REMAIN IN PLACE EXISTING WATER MAIN AND EXISTING SERVICE LINE SHOWN AS CROSS HATCHED TD BE RETIRED IN PLACE S.N. 2 AFTER NEW WATER MAIN IS PUT INTO SERVICE AND EXISTING METERS ARE CONNECTED TO THE NEW WATER MAIN SN 3 CUT, CAP AND RETIRE EXISTING WATER MAIN ON BOTH LIVE AND RETIRED SECTIONS OF PIPE S N4 INSTALL A LINE STOP PLUG VALVE (SIZE) EXISTING WATER METER PIT TO BE REPLACED. NEW SETTER AND APPURTENANCES TO BE INSTALLED IN SN5 NEW PIT. EXISTING METER WILL BE RELOCATED FROM THE EXISTING PIT TO THE NEW PIT NEW SERVICE LINE INSTALLED FROM NEW DISTRIBUTION MAIN AND CONNECTED TO EXISTING CUSTOMER SERVICE LINE S.N6 EXISTING WATER METER AND PIT TO REMAIN IN PLACE. NEW SERVICE LINE INSTALLED FROM NEW DISTRIBUTION MAIN AND CONNECTED TO EXISTING CUSTOMER SERVICE LINE S.N. 7 REMOVE EXISTING APPURTENANCE TO 18" BELOW GRADE AND FILL VOID WITH GRADE B BORROW BACKFILL SNS INSTALL A GATE VALVE (SIZE) S.N9 INSTALL A 3-WAY FIRE HYDRANT ASSEMBLY W/6" GATE VALVE S N. 10 INSTALL A FLUSH HYDRANT ASSEMBLY W/ 3" GATE VALVE S.N 11 INSTALL 2" HOPE CASING WITH 1" CTS-CL-200 (MIN.) SERVICE LINE WITH TRACER WIRE BY DIRECTIONAL BORE (LENGTH) I 0 m " w w I m ,<;�GE z HOUS! \ " w � > " w m 0 • 0 z z ::5 t,� ow +W \ .. ,£; � \ 0 e 0 w • w <C en I- - en ::i:: w I- \, z:::ie -o ..J a:: I LL () 0 I- -<( I- :::i,Z 0 () • w > z > ..J " w ! � ! !� •o <w 0" �- o, ,9 N� 0 � o, w � f2 �;; ·� = ·� ·, • .. �•J.J w - " -· s, 0 "o "'u wz z -, �� �9 s' <c Cl <6 <o ALL NEW MAINS TO BE CL-200 (MINIMUM) (IRON PIPE SIZE EQUIVALENT OUTSIDE DIAMETER) WITH TRACER WIRE UNLESS OTHERWISE SPECIFIED THIS PLAN VIEW IS PRIORITY #2 ALL NEW MAINS TO BE CL-200 (MINIMUM) (IRON PIPE SIZE EQUIVALENT OUTSIDE DIAMETER) WITH TRACER WIRE UNLESS OTHERWISE SPECIFIED THIS PLAN VIEW IS PRIORITY #2 INSTALL 80 L.F OF 4" REST JOINT CL-200 (MIN.)(IPS EQUIV OD) PIPE BY UNCASED BORE WITH TRACER WIRE I I I I I I ,I ' N z ::5 0 a_ 0 I + w 1B � < en lo � lLI I � I _;, z ::i: o (.) ffi . I I- 1- < Z :.t. p-...r- 0 50 f I 100 PLAN No. 1 \, � z <( 0 ..J 0 a_+ a, <O � � � I- . w <w I- I Cf) Cf) Wz Zo ..J 0 I- () I- I- z <( 0 � () w • z ..J SCALE: 1" � 100' I""'-•- I 0 50 100 PLAN No. 2 REVISIONS BID SET C 2023 Midwestern Engine�,�. Inc. 802 Wes! Broadway Street P.O. Box 295 Loogootec. Indiam47553 DATE NOV. 2023 DESIGN J.W.W. DRAWN K.J.G Q.C. CHECK PROJECT NUMBER 2017043-01 18 18 OF 54 I FIL£ NUMBER _ 43707 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2