Midwestern Engineers, Inc. Plan Preview
) I S.N. 1 S.N 2 S.N.3 S.N.4 S.N. 5 S.N.6 SN 7 S N 8 S.N. 9 S.N. 10 S.N.11 I GAR /,, OUSE ;.. '<. ✓ °M-15-18-304-020.001-017 'II" Bailey, ZacharyLee& Gissell / I "' SPECIAL NOTES EXISTING WATER MA!N TO REMAIN IN PLACE • MATCH LINE STA. 8+00 LINE CONT'D ON SHEET 32 PLAN 1 HOUSE 74-15-18-304-017.000-017 Balley, ZacharyLee& Gissel! INSTALL 20 L F OF 6" CL-200 (MIN ) >---'1-- J (IPS EQUIV. OD) PIPE BY UNCASED BORE WITH TRACER WIRE "" ' <' I \ I I I / I / .... f S.N.2 HOUSE'' --/-�1 // ¥- � SHED ( 74-15-18-304-ooa 000-011 S.N. 6 HOUSE 74-15-18-403-001.012-017 Garrison, Jimmie& Christy 74-15-18-304-018.000-0"7- ·1309 � Schulte, D Robert& Heather B , / E(1%)8W3i'PRT• 1, othyA&_w 1 Woolsey, Charles�& Mildre Winstead, Michele R(99%) ®�" ---"'cL SN. II (30; s,., -, :}, MEI JOB# 90038 ALE # 18191 < SHEET 12 PLAN 1 • � BLKT. i<.___ c1 POINT OF CONNECTION e--- ------ +-_., ' t �l2"CMP ..9 M,.9 t (� � -'-c1�--- M .. 9 WET TAP EX. 6" MAIN WITH A SN. 8 (6'; 6"x6"x6" STAINLESS STEEL TAPPING BLKT. 16'� SLEEVE AND A 6" TAPPING GATE I SN 9 -• I VALVE. STATIC PRESSURE 61 P.S.I. t �====--- --,- ----,== =' ·• \ �,.�:e======��_ _'.____cc=��,-�---�INSTALL 20 L.F. OF 6" CL-200 (MIN ) ll- (IPS EQUIV OD) PIPE BY UNCASED BORE WITH TRACER WIRE RIP RAP I • J.!il 4 - 15--13-403-005.000-017 ,,-- f, c:d,� Waggoner, Matthew& f- 18' lo Nicole Tempel ,,--- h-- f 12·cctJc . / , � � I HOUSE I 308 I P"' I ,, I S.N.. 11 (30) f ;I SN. 5 f �-- - t . �_bJ�� 0 ��/ ---�� Pl § =- 'ii . (!:YS�ONE j./!!ltii>i:-� IHOUSE� 74-15-18-304-011.000-017 Guisewhite, Brenda C 60+00 STONE SN6 '""12"1-mPE - � SN5 I 12"PVC - 8-4D3-007.000-017 , Zeth t® I HOUSE I I \ \ \ CR 340W ---�-,---�--- \ EXISTING WATER MAIN AND EXISTING SERVICE UNE SHOWN AS CROSS HATCHED TO BE RETIRED IN PLACE AFTER NEW WATER MAIN IS PUT INTO SERVICE AND EXISTING METERS ARE CONNECTED TO THE NEW WATER MAlN CUT, CAP AND RETIRE EXISTING WATER MAIN ON BOTH LIVE AND RETIRED SECTIONS OF PIPE INSTALL A LINE STOP PLUG VALVE (SIZE) EXISTING WATER METER PIT TO BE REPLACED. NEW SETTER AND APPURTENANCES TO BE INSTALLED IN NEW PIT. EXISTING METER WILL BE RELOCATED FROM THE EXISTING PIT TO THE NEW PIT. NEW SERVICE LINE INSTALLED FROM NEW DISTRIBUTION MAIN AND CONNECTED TO EXISTING CUSTOMER SERVICE LINE. EXISTING WATER METER AND PIT TO REMAIN IN PLACE. NEW SERVICE LINE INSTALLED FROM NEW DISTRIBUTION MAIN AND CONNECTED TO EXISTING CUSTOMER SERVICE LINE. REMOVE EXISTING APPURTENANCE TO 18" BELOW GRADE AND FILL VOID WITH GRADE B BORROW BACKFILL INSTALL A GATE VALVE (SIZE) INSTALL A3-WAY FIRE HYDRANT ASSEMBLY W/ 6" GATE VALVE INSTALL A FLUSH HYDRANT ASSEMBLY W/3" GATE VALVE INSTALL 2" HDPE CASING WITH 1" CTS-CL-200 (MIN.) SERVICE LINE WITH TRACER WIRE BY DIRECTIONAL BORE (LENGTH) I / I / / • ALL NEW MAINS TO BE CL-200 (MINIMUM) (IRON PIPE SIZE EQUIVALENT OUTSIDE DIAMETER)WITH TRACER WIRE UNLESS OTHERWISE SPECIFIED THIS PLAN VIEW IS PRIORITY #1 AND PRIORITY #2 (SEE PLAN FOR MORE INFORMATION) 40' R/W I \ HOUSE � \ rl 1 t M.,9 .,,1 1"1 �\'---" /Z '-- STONE STONE • ;: <O <--------< SN 2 I � l ... \ SHED � , • \ ' - "'i .., }'� HOUSE • ' • ' � " ;, . ' ., \ l'i 'i.'· ) - I . l - ' ; I \ l �-'l- POINT OF CONNECTION HOUSE WET TAP EX. 6" MAIN WITH A 6"x6"x6" STAINLESS STEEL TAPPING SLEEVE AND A 6" TAPPING GATE VALVE. STATIC PRESSURE 58 P.S.I "' "' " , SCALE: 1" � 50' �- 0 25 I 50 PLAN No. 1 REVISIONS BID SET C> 202) Midw�Slc'm Engincrrs. Inc. 802 Wcsl Ilrondway Street P 0. Box 295 Loogootee. lndi,ma 47553 DAlE NOV. 2023 DESIGN J.W.W. DRAWN K.J.G. Q.C. CHECK PROJECT NUMBER 2017043-01 31 31 OF 54 I FlLE NUMBER I 43694 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2