Midwestern Engineers, Inc. Plan Preview

0 3c � " Q 0 � > = a " <t ,i :ic: ii - • C � 0 w z N .� ", 00 . � ,< 00 s ��£ -. . ' ,_ ......... �9 ·" ��� ,. 0 V)j ,;j I'll oW .. olu � - --' � .. - .. c5 8 § .- 00 o< >Y •" "� "51ii << PIPING PAINT IDENTIFICATION COLORS SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW FLUORIDE - LIGHT BLUE PRIMARY COAGULANT - ORANGE CARBON - BLACK POTASSIMUM PERMANGANATE - PURPLE PIPE LABELS SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS ANO WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. IDENTIFICATION LABELS I TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS. VALVES. METERS AND EQUIPMENT. CHEMICAL FEED PIPING LEGEND - - - CHLORINE GAS SUPER CHLORINATED WATER -------- POTABLEWATER FLUORIDE _,,,,.. ____ POTASSIUM PERMANGANATE PHOSPHATE -""-,--- REMOVE CHEMICAL FEED LINE AND CONDUIT REMOVE CHEMICAL FEED LINE. CONDUIT TO REMAIN CHEMICAL FEED LINE / CONDUIT TO REMAIN FOR FUTURE USE PIPE LABEL REQUIREMENTS PIPE MIN LABEL MIN. LETTER DIAMETER SIZE HEIGHT 0.75" TO 1.25" 1"X 8" 0.5" 1-25" TO 2.5" 1"X 8" 0.75" 2.5"TO 8" 2" X 12" 1.25" 8"T010" 3"X 24" 2.5" 10"> 4" X 32'' 3.5" MECHANICAL PIPING LEGEND � EXISTING FINISHED WATER MAIN TO REMAIN �� EXISTING RAW WATER MAIN TO REMAIN � EXISTING BACKWASH WASTE MAIN TO REMAIN � EXISTING PIPING AND ACCESSORIES �� TO BE REMOVED I RETIRED r -.,-) PIPING INSULATION TO BE REMOVED L -----'� (CROSS HATCH COLOR PER MAIN TYPE) LEGEND �JD� BUILDING MODIFICATIONS WP..M (SEE SHEETS 01.02 THRU 01 05 FOR DETAILS) � CHEMICAL FEED EQUIPMENT � TO BE REMOVED CONSTRUCTION SEQUENCE FOR EXISTING PLANT No. 1 (PUMP ROOM/ AERALATER ROOM #1): 1. RESIDENTIAL M�TER RECONNl?:CTIONS ALONG SR 66 SHALL BE COMPLETED BY THE: DIV. I CONTRACTOR PRIOR TO ANY DEMOLITION/ RETIREMENT OF THE EXISTING PLANT No. 1 AND fHE 5"SYSTEM FINISHED WATER SUPPLY MAIN TO THE NORTH 2. !N$TALLATION bF NEV\16"FINISHED WATER BYPASS MAIN AND NEW 8" RAW WAT�R BYPASS MAIN TO BE COMPLETED PRIOR TO RENOVATION OF THE EXISTING PLANT NG 1. SEE SHEEt C'103 FOR DETAILS. 3. CHEMICAL FEED LINES SERVING PLANT NO. 1 SHALL BE REMOVED COMPLETELY FROM THEIR ORIGINAL SOURCE TO THE INJECTION POINTS. EXISTING CONDUIT$ TO BE RE-UTILIZED WHERE POSSIBLE FOR NEW CHEMICAL FEED SUPPLY. (SEE SHEETS D1.02, M1.05 AND M1.06) 4. EXISTING PLANT No. 1 MECHANICAL PIPING AND ALL ASSOCIATED APPURTENANCES TO BE DEMOLISHED/ RETIRED AND DISPOSED. (SEE SHEETS D1.02 AND D1.04) 5. DEMOLITION AND DISPOSAL OF AERALATER No. 1 (SEE SHEETS D1.02, D1.04 AND D1.05) 6. REMOVAL AND MODIFICATION OF ELECTRICAL EQUIPMENT FOR PLANT No. 1 (SEE SHEET 01.06) 7. BUILDING RENOVATIONS, PAINTING AND ASSOCIATED BUILDING MAINTENANCE SHALL BE COMPLETED PRIOR TO INSTALLATION OF NEW EQUIPMENT, PIPING, PUMPS, ETC. (SEE SHEETS S1.01 THRU S1.06) 8. INSTALLATION AND PAINTING OF NEW AERALATOR No. 1, PIPING, PUMPS, ETC. (SEE SHEETS M1.02, M1.03 AND M1.04) 9. INSTALLATION OF NEW CHEMICAL FEED EQUIPMENT AND CHEMICAL FEED LINES ASSOCIATED WITH SERVICING EXISTING PLANT No. (SEE SHEETS M1.01 AND M1.05 THRU M1.07) 10. NEW PLANT No. 1 SHALL BE CONSTRUCTED AND FULLY OPERATIONAL PRIOR TO BEGINNING IMPROVEMENTS TO EXISTING PLANT No. 2. CONSTRUCTION SEQUENCE FOR EXISTING PLANT No. 2 (AERALATER ROOM #2) 1. 2. 3. 4. 5. 6 7. 8. NEW PLANT No. 1 SHALL BE CONSTRUCTED AND FULLY OPERATIONAL PRIOR TO BEGINNING IMPROVEMENTS TO EXISTING PLANT No 2 CHEMICAL FEED EQUIPMENT AND CHEMICAL FEED LINES SERVING PLANT No. 2 SHALL BE REMOVED COMPLETELY FROM THEIR ORIGINAL SOURCE TO THE INJECTION POINTS. EXISTING CONDUITS TO BE RE-UTILIZED WHERE POSSIBLE FOR NEW CHEMICAL FEED SUPPLY. (SEE SHEETS 01.03, M1.05 AND M1.06) REMOVE INSULATION ON ALL MECHANICAL PIPING IN EX. PLANT No. 2. (SEE SHEET M1.02) RENOVATE AERALATOR No. 2 AND ALL EXISTING PIPING. (SEE SHEET M1 02) REMOVAL AND MODIFICATIONS OF ELECTRICAL EQUIPMENT FOR PLANT No. 2. (SEE SHEET D1.06) BUILDING RENOVATIONS, PAINTING AND ASSOCIATED BUILDING MAINTENANCE SHALL BE COMPLETED PRIOR TO INSTALLATION OF NEW EQUIPMENT, PUMPS, ETC. (SEE SHEET M1.02) INSTALLATION OF NEW CHEMICAL FEED EQUIPMENT AND CHEMICAL FEED LINES ASSOCIATED WITH SERVICING EXISTING PLANT No. 2. (SEE SHEETS M1.02 AND M1.05 THRU M1.07) INSTALLATION OF NEW PHOSPHATE, FLUORIDE, AND PERMANGANATE EQUIPMENT AND ASSOCIATED CHEMICAL FEED LINES TO PLANT No 1 AND PLANT No. 2. SEE SHEETS M1.01, M1.02 AND M1.07 FOR CHEMICAL FEED DETAILS. EXISTING 5"FINISHED WATER DISTRIBUTION MAIN (TO TANK No. 1) REMOVE EXISTING BACKWASH HOLDING TANK TO 18"BELOW GRADE AND FILL VOID WITH GRADE 'B' BORROW MATERIAL ' • ) i'. EXISTING 5"BACKWASH DRAIN LINE I --- "'*''-- "' L____J EX HEALY-RUFF PANEL SAMPLE LINE FROM ONSITE TANK I I I I I I PUMP ROOM I I 1 =rF I 11,. I I CL. PUMP I L CHLORINE ROOM \ \ \ \ I I ' ' ' ' / / - X *"' DESK / FILING 'I; � I PERM,GANATE " WA}l:R 11 11 11 � 1 1 1 I - ' ' - / / \ I \I IL "' ,� - �- - �,,� EXISTING 6" BACKWASH DRAIN LINE J ' SOF_TfNER \ 1---�- 8'11 1 1 _)1 " AERALATER ROOM #1 EXISTING PLANT No. 1 A[RALATER No. 2 \ \ \ ',. \ i \1 � 0 � , AERALATER ROOM #2 .L L_ _·_i t _· _· -...-x -,�f- ---------------- - -...---_J ,,_ _ _ "'-:�- ,e --- oc --- ,e --- oc --- "'___ ,e --- ,e - -' --- "'_ __ ,e -- - ,e - - "'__ _ ,, _ __J ;t- -- EXISTING 6"FINISHED WATER DISTRIBUTION MAIN (TO TANK No. 2) N 0 EXISTING PLANT No. 2 [)<)---- EXISTING 8"RAW WATER SUPPLY MAIN FROM WELLS 4 & 5 DEMOLITION PLAN SCALE, 1/4" � 1'-0" '·� -9,..,-- ,,__ ,�"�-- EXISTING 5"RAW WATER SUPPLY MAIN FROM WELLS 1, 2 & 3 EXISTING 12" FINISHED WATER DISTRIBUTION MAIN (TO TANK No. 3) EXISTING WATER TREATMENT PLANT - DEMOLITION PLAN REV1SIONS BID SET C 2023 Midwestern Enginc-crs. Inc. 802 West Broadwav Sn"et P.O. Bo� "295 Loogootee. Indian" 47553 DATE NOV. 2023 DESIGN J.W.W. DRAWN M.M.C.L'.K.J.G. Q.C. CHECK PROJECT NUMBER 2017043-01 01 .01 10 OF 47 I FllE NUMBER I 43661 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2