Midwestern Engineers, Inc. Plan Preview

3 PUMP ROOM 11--+- 6 ' ?I I - 4 � � " % ' • • � 0 ,, z "� - � - 0 < r-, U.: -, • Q ,_ �; Q -I a � '.":: > ' - 1/) ;!! ;_; = '' w " t.i o, Sw :i: tr - Q ., !>I >0 :r. 2� ,- 00 o< "' cN s, ' ' <> 9 DISCONNECT ANO REMOVE CHLORINE CHEMICAL FEED LINE FOR PLANT No. 1 7 X I I I I L_ ' I L ' I L ' I L AERALATER ROOM #1 CHLORINE ROOM I I I \ I I \ ' / I ' / ' / / - =- 1 "\ � " ' '>l,;----(_2] 1----0 '\ ? �\ \ \ \ ENTRY/ LAB \ "· PERM,NGANATE t \ / // DEMOLITION / RETIREMENT LEGEND 1 EXISTING WATER LINES SHALL BE CAPPED AT TEES, FLOOR, ETC. AND ARE TO BE REMOVED. EXISTING CHEMICAL FEED LINES AND CHEMICAL FEED EQUIPMENT SERVING THE PUMP ROOM 2 AND THE AERALATER #1 ROOM SHALL BE DISCONNECTED AT THE SUPPLY SOURCE AND REMOVED EXISTING CONDUITS TO BE RE-UTILIZED FOR NEW CHEMICAL FEED SUPPLY WHERE POSSIBLE. SEE SHEETS M1.01 AND M1.07 FOR CHEMICAL FEED SUPPLY IMPROVEMENTS ALL PIPING, PUMPS, METERS, EQUIPMENT AND ASSOCIATED APPURTENANCES AS SHOWN 3 WITH DARK GRAY CROSS HATCH ARE TO REMOVED AND DISPOSED OF IN ACCORDANCE TO LOCAL, STATE AND FEDERAL REGULATIONS. 4 DOORS TO BE REPLACED AND WINDOWS TO BE REMOVED AND EXISTING WINDOW CAVITY TO BE FILLED SEE STRUCTURAL PLANS FOR MORE INFORMATION. 5 CUT DOORWAY INTO CMU WALL. 6 ALL RETIRED PIPING PENETRATIONS THRU THE EXISTING WALLS SHALL BE FILLED WITH FAST SETTING CONCRETE SEE STRUCTURAL PLANS FOR MORE INFORMATION. 7 EXISTING CONCRETE PUMP PEDESTALS TO BE REMOVED. SEE STRUCTURAL PLANS FOR MORE INFORMATION. EXISTING INFLUENT STEEL PIPE TO BE CLEAN CUT A MIN. OF 10" ABOVE FINISHED FLOOR FOR 8 CONNECTION TO NEW INFLUENT PIPING SEE SHEETS M1 01 AND M1.03 FOR MECHANICAL PIPING IMPROVEMENTS. 9 CAP EXISTING 6" BACKWASH LINE A MIN. OF 3 FEET FROM EXTERIOR WALL FACE AND FILL RETIRED LINE UNDER THE BUILDING WITH FLOWABLE FILL. 10 EXISTING PIT TO BE FILLED WITH CONCRETE FLUSH WITH THE EXISTING CONCRETE FLOOR SLAB SEE STRUCTURAL PLANS FOR MORE INFORMATION. 11 EXISTING AERALATER No. 1 FOUNDATION BRICKS, ETC. TO BE REMOVE. SEE STRUCTURAL PLANS FOR MORE INFORMATION 12 REMOVE & DISPOSE OF AIR COMPRESSOR AND ALL ASSOCIATED PIPING SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/ POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW FLUORIDE - LIGHT BLUE PHOSPHATE-ORANGE SODIUM PERMANGANATE - PURPLE PIPE LABELS SHALL BE INSTALLED EVERY25' TO50' ALONG STRAIGHT RUNS. AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS IDENTIFICATION LABELS/ TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS AND EQUIPMENT. CHEMICAL FEED PIPING LEGEND -- -- -- CHLORINE GAS - -- SUPER CHLORINATED WATER -�,-v. POTABLE WATER -� ... _., ___ -v..- FLUORIDE POTASSIUM PERMANGANATE PHOSPHATE � REMOVE CHEMICAL FEED LINE AND CONDUIT �-X· --*�- REMOVE CHEMICAL FEED LINE, CONDUIT TO REMAIN MECHANICAL PIPING LEGEND � EXISTING FINISHED WATER MAIN TO REMAIN wzm: EXISTING RAW WATER MAIN TO REMAIN � EXISTING BACKWASH WASTE MAIN TO REMAIN � EXISTING PIPING TO BE REMOVED/ RETIRED LEGEND WJD� BUILDING MODIFICATIONS W°'.U� (SEE SHEETS 01.03 THRU 01.05 AND S1.01 THRU S1.06 FOR DETAILS) � CHEMICAL FEED EQUIPMENT TO BE REMOVED PIPE LABEL REQUIREMENTS PIPE MIN LABEL MIN. LETTER DIAMETER SIZE HEIGHT 075" TO 1.25" 1" X 8" 0.5'' 1.25" TO2.5" 1" X 8" 0.75" 25" TO 8" 2" X 12" 1.25" 8" TO 10" 3" X24" 2.5" 1 O" > 4" X32" 3.5" N SCALE: 1/2" = 1'- 0" 0 DEMOLITION PLAN CHLORINE ROOM AERALATER ROOM #1 PUMP ROOM #1 .. AERALATER No. 1 REVISIONS BID SET C 2023 Midwcslern Engineer>. Inc. 802 Wes! Bro:idwav Street P.O Box 295 Loo�oolcc. lndiana 47SSJ DATE NOV. 2023 DESIGN J.W.W. DRAWN M.M.C-i'K.J.G. Q.C. CHECK PROJECT NUMBER 2017043-01 01 .02 11 OF 47 EXISTING PLANT No. 1 - DEMOLITION PLAN I FILE NUMBER I 43660 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2