Midwestern Engineers, Inc. Plan Preview
=- 1 ,. , < , " � I z e ' z , • , � � •'" 0 ,< z ,< � �,�� Q ........�9 .• M C -1� i "' •" ' - = lfl l * 3 0 .. :: � • ... 0 ..i !,,< 5: ii M � <(:: Q ,o .al 8� .- 00 o< ::i:9 "' <c "51!, <c FLUORIDE = �_,__ 2 V/ /{ (y R �) r1 • • 1( , )( 1( -+:: l( u * t i +� t I ' t X --- t ' ' 8" 4'' I I I I I I I I I 0-- ' / \ I \ I \ I \ I II 1 A[RALAT[R No. 2 r· I I I � L. ' / I / L. 6" -- PHOSPHATE CL. PUMP FLUORIDE WATER SOFTENER PERMANGANATE PHOTO TAKEN IN 2004 PERMANGANATE AERALATER No. 2 �x -�x �-,<!',,3(1 AERALATER ROOM #2 t- -tl--+---fAAi L:iL�C:fH<EEiM;;;ICC. AOJL�F�ESEEID;-;P;;; I PPil NNGG-1 �\ "\ "' t i \ \ "' J \ X \� AERALATER ROOM #2 THAT IS CURRENTLY NOT IN USE TO BE REMOVED AND DISPOSED SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW FLUORIDE - LIGHT BLUE PHOSPHATE-ORANGE SODIUM PERMANGANATE - PURPLE PIPE LABELS SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. IDENTIFICATION LABELS/ TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS. VALVES, METERS AND EQUIPMENT CHEMICAL FEED PIPING LEGEND -- --- -- CHLORINE GAS - - SUPER CHLORINATED WATER -w--w POTABLE WATER FLUORIDE __.,,,,,u-:_,.,.",.-- POTASSIUM PERMANGANATE _,,,,_,...,_ PHOSPHATE � REMOVE CHEMICAL FEED LINE AND CONDUIT lf )( K x X X: REMOVE CHEMICAL FEED LINE, CONDUIT TO REMAIN CHEMICAL FEED LINE TO REMAIN FOR FUTURE USE PIPE LABEL REQUIREMENTS PIPE MIN LABEL MIN. LETTER DIAMETER SIZE HEIGHT 0.75" TO 1.25" 1" X 8" 0.5 '' 1.25" TO 2.5" 1" X 8" 0.75" 2.5" TO 8" 2" X 12" 1.25" 8" TO 10" 3" X 24" 2.5" 10" > 4" X 32" 3.5" N 0 DEMOLITION PLAN SCALE: 1/2" = 1' -0" DEMOLITION/ RETIREMENT LEGEND 1 EXISTING WATER LINES SHALL BE CAPPED AT TEES, FLOOR, ETC. AND ARE TO BE REMOVED. EXISTING CHEMICAL FEED LINES AND CHEMICAL FEED EQUIPMENT IN AERALATOR ROOM #2 2 SHALL BE REMOVED AND DISPOSED IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS. EX. CONDUIT TO BE RE-UTILIZED FOR NEW CHEMICAL FEED SUPPLY WHERE POSSIBLE. SEE SHEETS M1 .02 AND M1 07 FOR CHEM FEED SUPPLY IMPROVEMENTS. 3 ALL PIPING AS SHOWN WITH DARK GREY SHADING TO HAVE PIPING INSULATION REMOVED AND DISPOSED IN ACCORDANCE TO LOCAL, STATE. AND FEDERAL REGULATIONS. 4 DOORS TO BE REPLACED AND WINDOWS TO BE REMOVED AND EXISTING WINDOW CAVITY TO BE FILLED. SEE STRUCTURAL PLANS FOR MORE INFORMATION. 5 EXISTING AERALATER NO. 2 TO BE RENOVATED. REMOVE INSULATION, THEN DRAIN, REMOVE FILTER MEDIUM, AND SAND-BLAST TANK INTERIOR. REPAINT EXTERIOR. MECHANICAL PIPING LEGEND � EXISTING FINISHED WATER MAIN TO REMAIN � EXISTING RAW WATER MAIN TO REMAIN � EXISTING BACKWASH WASTE MAIN TO REMAIN � EXISTING PIPING TO BE REMOVED/ RETIRED r-- 1 PIPING 1NsuLAT10N To sE REMOVED L_� (CROSS HATCH COLOR PER MAIN TYPE) LEGEND !?'JP� BUILDING MODIFICATIONS Wf� (SEE SHEETS D1.03 THRU D1.05 AND S1.01 THRU S1.06 FOR DETAILS) � CHEMICAL FEED EQUIPMENT TO BE REMOVED EXISTING PLANT No. 2 - DEMOLITION PLAN • - ·- .:: REVlSIONS BID SET C 2023 Midwesl�m Engineers. Inc. 802 We.sl Broadwav Sm"'! P.O. Box 295 Loo�ootee. Indiana 47553 DATE NOV. 2023 DESIGN J.W.W. DRAWN M.M.C. ,' . K.J.G. Q.C. CHECK PROJECT NUMBER 2017043-01 01 .03 12 OF 47 I Fll£ NUMBER I 43659 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2