Midwestern Engineers, Inc. Plan Preview

EXISTING HEATER TO BE REMOVED 10 0 I ' I I I c________ 1 - - 1 I 1, I I -- � EXISTING EXHAUST FAN TO BE REMOVED CHLORINE l ROOM [\ ALL EXISTING ELECTRICAL _:�?---- lll_EQUIPMENT TO BE REMOVED, 0 0 0 0 /@.,�---DISCONNECT AND REMOVE FLOOR &, DRAIN AND ASSOCIATED WASTE PIPING BACK TO MAIN AND CAP. CUT AND PATCH FLOOR TO MATCH EXISTING A 11 11 11 SEE ONE LINE DIAGRAM FOR MORE INFORMATION PUMP ROOM 0 D 01 C L "-EXISTING UNIT HEATER TO BE REMOVED I I I I I I I L_ _ __J IEXISTING WATER TOWER PANEL TO BE REMOVED l� I I 11 11 11 I I I I ll I "'" - 11 "0• � ENTRY/LAB 11 )1 (\_ EXISTING CEILING u----- MOUNTED UNIT HEATER TO BE REMOVED /,, � I -EXISTING DEHUMIDIFIER I 1 -EXISTING EXHAUST FAN TO BE REMOVED TO BE REMOVED , / I 1 -- 1 I I__ 1 --- 1 I I f--+---EXISTING TRANSFER SWITCH TO BE REMOVED >---+--- EXISTING PANELBOARD TO BE REMOVED I � XISTING AERALATER #1 CONTROL L ANEL TO BE REMOVED ,- - 1 I I n------- I I I - EXISTING INTAKE LOUVER TO BE REMOVED (.Y : I I I I ,I �-l�--1 I 1 ---- ' I, I­ EXISTING HIGH SERVICE PUMP #1 MOTOR----, 1 STARTER/DISCONENCT TO BE REMOVED I EXISTING AERALATER #2 CONTROL PANEL TO BE REMOVED 1- ) , ���������ISTING HIGH SERVICE PUMP #2 MOTOR---1 0 D I STARTER/DISCONENCT TO BE REMOVED I ��- ='i11 "� �- I • 1- DISCONNECT AND REMOVE FLOOR - DRAIN AND ASSOCIATED WASTE PIPING � ' BACK TO MAIN AND CAP. CUT AND I PATCH FL ,O OR TO MATCH EXISTING 1 EXISTING HIGH SERVICE PUMP------� 1 J : l'oo'"1' "'"" rn " LJ rn , A[RALATER No. 1 ==:,,,, I 1 1 ! I >------+ EXISTING DEHUMIDIFIER 1 --�TO BE REMOVED / '' DISCONNECT AND REMOVE FLOOR / / DRAIN AND ASSOCIATED WASTE PIPING ' / / BACK TO MAIN AND CAP. CUT AND 1 ' 1'-, / PATCH FLOOR TO MATCH EXISTING I - yJ,' EXISTING AIR COMPRESSOR- o '9 AND PIPING TO BE REMOVED 11 u - 0 AERALATER ROOM #1 EXISTING WALL EXHAUST---< FAN TO BE REMOVED I- - 1 1 � --EXISTING CL PUMP CONTROL PANEL TO BE REMOVED I AERALATER No. 2 AERALATER ROOM #2 EXISTING UNIT HEATER---/ 1 ==11 TO BE REMOVED EXISTING WATER TREATMENT PLANT - ELECTRICAL HVAC AND PLUMBING DEMOLITION PLAN SCALE, ')/," � 1'-0" NOTE: ALL TI-!ERMOSTAT CONTROL, 120V-1¢, 208V-1¢ AND 208V-3¢ CONDUIT & WIRE SHALL BE REMOVED AS A RESULT OF DEMOLISHING EQUIPMENT. NOTE: ALL EXISTING INTERIOR AND EXTERIOR LIGHTS SHALL BE REMOVED AND REPLACED AS A PART OF THE PROPOSED PROJECT. • - REVISIONS 11/8/23 BID SET C 2023 �1idwt•s1cm Engineer,. Inc. 801 We�! Broadway Str�el P.O. Box 295 Loogoo1c�. lndian;, �7553 DATE NOVEMBER 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK J.W.W. PROJECT NUMBER 2017043-01 01 .06 15 OF 47 I FU NUMBER I 43656 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2