Midwestern Engineers, Inc. Plan Preview
DOOR & WINDOW SCHEDULE OPENING No DOOR / WINDOW FRAME HEAD DTL JAMB DTL SILL DTL HARDWARE SET 101 01 F1 H1 J1 S1 No. 2 102 -- -- -- -- -- -- 103 -- -- -- -- -- No. 4 104 02 F3 H3 J3 S3 No. 3 105 PAIR 01 F2 H2 J2 S2 No. 1 106 -- -- -- -- -- No. 4 A -- -- - - -- -- B -- -- -- -- -- NOTE: HAZARDOUS LABELS AS SHOWN BELOW SHALL BE INSTALLED ON INGRESS SIDE OF (SEE DOOR & WINDOW SCHEDULE ON THIS SHEET FOR REQUIRED DOOR LABELS) DOORS. CHLORINE GAS SODIUMPERMllNGAN� _.., __ 1 1 n11rn�� --·-- ..;,:,r.;;..,. .. -- --- � ��·r.:� " .,, . i:' 10" ·---- DOOR HARDWARE SCHEDULE HARDWARE SET 6 1 1 1 2 1 1 2 HARDWARE SET 3 1 1 HARDWARE SET CT I 0 · - -· - - No. 1 DOOR HINGE OFFICE/ENTRY MORTISE LEVER LOCK ADA THRESHOLD (6 FT) PERIMETER SELF-ADHESIVE WEATHERSTRIPPING (21 FT) DOOR SWEEP (BOTH DOORS) KICK DOWN HOLDER (INACTIVE LEAF) DOOR CLOSER (ACTIVE LEAF) MANUAL FLUSH BOLT (INACTIVE LEAF) OVERLAPPING ASTRAGAL (ACTIVE LEAF) No. 2 DOOR HINGE PRIVACY MORTISE LEVER LOCK No. - DOOR --- -· - bOOR .. CLOSER HING[ . EXlf RIM OtvlCE w/ NIGHT LATCH ADA THRESHOLD (3 FT) PERIMETER SELF-ADHESIVE WEATHERSTRIPPING (17 FT) DOOR BOTTOM SHOE DOOR CLOSER HARDWARE SET No. 4 NOTE: 1 OFFICE/ENTRY MORTISE LEVER LOCK ANSI A156.1 ANSI A156.2 ANSI A156.21 ANSI A156.22 ANSI A156.22 ANSI A156.16 ANSI A156.4 ANSI A156.16 ANSI A156.22 ANSI A156.1 ANSI A156.2 ANSI A156.4 ANSI A156. I ANSI A156.2 ANSI A156.21 ANSI A156.22 ANSI A156.22 ANSI A156.4 ANSI A156.2 1) ALL HARDWARE LISTED AND OR SUBSTITUTES SHALL BE GRADE 1. 2) EXISTING DOORS TO REMAIN SHALL BE PAINTED TO MATCH NEW DOORS US260/652 US260/626 MILL ALUMINUM BLACK MILL ALUMINUM US26D/626 689 US260/626 MILL ALUMINUM US26D/652 US26D/626 689 US26D/652 US26D/626 FRP BLACK MILL ALUMINUM 689 US26D/626 - REMARKS NON-INSULATED EXISTING OPENING EXG. DOUBLE DOOR TO REMAIN INSULATED, GAS TIGHT, 1 HR FIRE RATED INSULATED EXG. DOUBLE DOOR TO REMAIN EXISTING OPENING EXISTING WINDOW TO BE REPLACED w/ 3 HR RATED GAS TIGHT FRAME & GLAZING IVES/ 5BB-1-HW-4.5x4.5-NRP SCHLAGE / LV9050-03B ZERO INTL. / 65-A ZERO INTL. / 188S-BK-25 ZERO INTL. / 8193-AA IVES / FS452 LCN / 4030-3049SCNS (PARALLEL MNT) IVES / FB458 (TOP & BTM) w/ DUST PROOF STRIKES DP-1 ZERO INTL. / 905-AA IVES/ 5BB-1-HW-4.5x4.5-NRP SCHLAGE / L9040-03B LCN / 4030-3049SCNS (PARALLEL MNT) IVES/ 5BB-1-HW-4.5x4.5-NRP VON DUPRIN / 9875L-NL w/ SCHLAGE / 038 LEVER CHEM-PRUF ZERO INTL. / 188FS-BK-17 PEMKO / 210AV LCN I 4030-3049SCNS (PARALLEL MNT) SCHLAGE / LV9050-03B EXISTING CMU WALL 079200-JOINT SEALANTS SEALANT "JS-#2" EA. SIDE-�= w/ MTL FLASHING DRIP HARDWARE SET NO. 3 WEATHERSTRIPPING _,'it-11 081743-FRP DOORS & FRAMES SLEEVE ANCHORS PER DOOR MFGR FOR "EXISTING MASONRY WALL" 081743-FRP DOORS & FRAMES ll-+-+---FACTORY PRIMED INSULATED FRP FLUSH PANEL DOOR & FRAME H3 DOOR HEAD DETAIL SCALE: 1 1/2" � 1'-0" 079200-JOINT SEALANTS SEALANT "JS-#2" EA. SIDE-� w/ MTL FLASHING DRIP HARDWARE SET NO. 1 WEATHERSTRIPPING 081743-FRP DOORS & FRAMES SLEEVE ANCHORS PER DOOR MFGR FOR "EXISTING MASONRY WALL" 0 081743-FRP DOORS & FRAMES ll--+-+-+--FACTORY PRIMED INSULATED FRP FLUSH PANEL DOOR & FRAME H2 DOOR HEAD DETAIL SCALE: 1 1/2" � 1'-0" EXISTING CMU WALL EXISTING CMU 079200-JOINT SEALANTS SEALANT "JS-#2" EA. SIDE HARDWARE SET NO. 3 WEATHERSTRIPPINIG ..:;:ir-'..dbr� ,- "' 081743-FRP DOORS & FRAMES Lc..L..JJ------�- FACTORY PRIMED INSULATED FRP FLUSH PANEL DOOR & FRAME J3 DOOR JAMB DETAIL SCALE: 1 1/2" - 1'-0" 079200-JOINT SEALANTS SEALANT "JS-#2" EA. SIDE 081·743-FRP DOORS & FRAMES SLEEVE ANCHORS PER DOOR MFGR FOR "EXISTING MASONRY WALL" DOOR JAMB DETAIL SCALE: 1 1/2" � 1'-0" 079200-JOINT SEALANTS SEALANT "JS-#3" EA. SIDE ';!Ir +- 051200-STRUCTURAL STEEL FRAMING L4x3xfi," GALV ANGLE EA. SIDE [ANGLES TO HAVE MIN. 4" BRG.] 042000-UNIT MASONRY FINE GROUT EA. SIDE OF DOOR JAMB EXISTING CMU 081743-FRP DOORS & FRAMES SLEEVE ANCHORS PER DOOR MFGR FOR "EXISTING MASONRY WALL" 081743-FRP DOORS & FRAMES ll-+--1-->�� FACTORY PRIMED NON-INSULATED FRP FLUSH PANEL DOOR & FRAME DOOR HEAD DETAIL SCALE: 1 1/2" � 1'-0" 079200-JOINT SEALANTS SEALANT "JS-#3" EA. SIDE 081743-FRP DOORS & FRAMES SLEEVE ANCHORS PER DOOR MFGR FOR "EXISTING MASONRY WALL" J1 ,-,---1/"""'1.:iaFc "' � 081743-FRP DOORS & FRAMES �l-1----- -�-FACTORYPRIMED NON-INSULATED FRP FLUSH PANEL DOOR & FRAME DOOR JAMB DETAIL SCALE: 1 1 /2" - 1'-0" 081743-FRP DOORS & FRAMES FACTORY PRIMED INSULATED FRP FLUSH PANEL DOOR & FRAME ----tf?lf-- HARDWARE SET NO. 3 IL..+---tt'- iw!fiEA�T¢!HEfi Rl' s;1T'RR�IP? Pif1 NKG� 0 079200-JOINT SEALANTS --"'C:::::==-Jrlr'ii SEALANT "JS-#2" HARDWARE SET No. 3 DOOR BTM SHOE 079200-JOINT SEALANTS SEALANT "JS-#4" .. . . . ... . . . ·· . ·� · ·· " · • • DOOR SILL S3 f-----�-� SCALE: 1 1/2" - 1'-0" 081743-FRP DOORS & FRAMES FACTORY PRIMED INSULATED HARDWARE SET NO. 3 THRESHOLD FRP FLUSH PANEL DOOR & FRAME ---Hf'df- HARDWARE SET NO. 1 ILJ--1:ct-�- �WiiEA� TH� E�R� Scri TR�l� PP� l�N� Gc...J. 079200-JOINT SEALANTS SEALANT "JS-#4" 0 DOOR SILL S2 1------- SCALE: 1 1/2" - 1'-0" 081743-FRP DOORS & FRAMES FACTORY PRIMED NON-INSULATED FRP FLUSH PANEL DOOR & FRAME - - SC"t--t--t 079200-JOINT SEALANTS SEALANT "JS-#3" EA. SIDE -==--H SEALANT "JS-#1" 033000-CIP CONCRETE CONTINUE VAPOR RETARDER VERT. AGAINST EXG SLAB FOR BOND BREAK . ·5. -. . -. <1 DOOR SILL S1 f---���� SCALE: 1 1/2" � 1'-0" 3) SUBSTITUTES FOR LISTED DOOR HARDWARE MFR SHALL BE "HAGER & NATIONAL GUARD, INC." OR ENGINEER PREAPPROVED EQUAL. ' <O <D D2 3'-o " r 081743-FRP DOORS & FRAMES --t-- FACTORY PRIMED FRP FLUSH PANEL DOOR DOOR PANEL SCALE: 1/2" - 1'-o" ' 0 I c- D1 3'-0" 08174,l-FRP DOORS & FRAMES -+--FACTORY PRIMED FRP FLUSH PANEL DOOR DOOR PANEL SCALE: 1/2" � 1'-0" <O I <D F3 081743-FRP DOORS & FRAMES -FACTORY PRIMED FRP DOOR FRAME 3'-Q" ,l,l 2" DOOR FRAME SCALE: 1/2" - I '-0" 0 I c- 081743-FRP DOORS & FRAMES - FACTORY PRIMED FRP DOOR FRAME DOOR FRAME SCALE: 1/2" - 1'-0" "' +---+ ' 0 I c- 3 '-0" 081743-FRP DOORS & FRAMES -FACTORY PRIMED FRP DOOR FRAME ll 2" F1 DOOR FRAME SCALE: 1/2" � 1'-0" PROPOSED DOOR & WINDOW ELEVATIONS & DETAILS REVISIONS BID SET � 2023 Midwestern Engineers, Jnc. 802 We.st Broadway Street P.O. Box 295 Loogootee, Indiana 47553 DATE NOV. 2023 DESIGN T.M.K. DRAWN T.M.K. a.c. CHECK PROJECT NUMBER 2017043-01 S1 .06 21 OF 47 I FllE NUMBER 43650 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2