Midwestern Engineers, Inc. Plan Preview
--- -·-""- i EXISTING 6" FINISHED WATER EFFLUENT - • Go- -- NEWS" RAW WATER INFLUENT I I I I I I r I 4• (20"MIN.) 4 4 �----��--";*:--. . � � . . .-� •�";;*-"�"""'*;-. ---- --,:-..'-*"" -: . �- ·-· .. .. .. ·• . .. . - [] ... •. . . . 8 . . . .. . 1 • • SECTION SCALE, 1/2" � 1'-0" . . . .... . -:: 8 4 • • • '. -� ·4 . . • . - -·--· --· r --- 0 . 0 •· ·- . ,· · ...... - • 1 • 4- .•·. - . • I-ti, i-i-- 12 .. . . · . . . (12" MIN.) . •-· _., . · . � .,; EXISTING 6" RAW WATER INFLUENT SECTION SCALE, 1 /2" � 1'-0" 1 8 - 2 MECHANICAL PIPING KEY 1 NEW AERALATER No. 1 - SEE SHEET M1.04 FOR DETAILS 2 6" D.I. SPOOL 3 6" BUTTERFLY VALVE 4 6" D.I. 90 ° ELBOW 5 6"x6"x6" D.I TEE 6 6"x3" 0.1. REDUCER 7 NEW HIGH SERVICE PUMP (SEE SPECIFICATIONS) 8 PRESSURE GAUGE (0-100 PSI) WITH TRANSDUCER 9 6" SWING CHECK VALVE 10 6"x4" D.I. REDUCER 11 4" BUTTERFLY VALVE 12 4" D I. SPOOL 13 6"x4" D.I. REDUCING ELBOW 14 4" SERIES 2100 MEGA FLANGE ADAPTER BY EBBA IRON, INC. OR EQUAL 15 4" ELECTROMAGNETIC FLOW METER 16 PRESSURE GAUGE (0-200 PSI) WITH TRANSDUCER 17 ALUMINUM OR STAINLESS STEEL PIPE SUPPORT STAND 18 6" D.I. 45 ° ELBOW NEW 6" RAW WATER INFLUENT '-- --1 - TERMINATE BACKWASH DRAIN LINE A MINIMUM OF 6" ABOVE FINISHED FLOOR ELEVATION 2 PIPING MANIFOLD AND VALVES SUPPLIED BY AERALATER TREATMENT UNIT MANUFACTURERS ..----$·1------------------------------"--- PIPING PAINT IDENTIFICATION COLORS SANITARY - DARK GREY RAW WATER - OLIVE GREEN FINISH/POTABLE WATER - DARK BLUE CHLORINE (GAS & SOLUTION) - YELLOW FLUORIDE - LIGHT BLUE PHOSPHATE-ORANGE SODIUM PERMANGANATE - PURPLE PIPE LABELS SHALL BE INSTALLED EVERY 25' TO 50' ALONG STRAIGHT RUNS, AT ALL CHANGES IN DIRECTION ON BOTH SIDES OF THE TURN, AT BOTH SIDES OF ENTRY POINTS THROUGH THE FLOORS AND WALLS, NEXT TO ALL FLANGES AND VALVES AND SHALL INCLUDE FLOW DIRECTION OF CONTENTS. IDENTIFICATION LABELS / TAGS SHALL BE INSTALLED ON ALL TANKS, PUMPS, VALVES, METERS AND EQUIPMENT. CHEMICAL FEED PIPING LEGEND -- --- - CHLORINE GAS SUPER CHLORINATED WATER - SUPER CHLORINATED WATER IN EX. CONDUIT -c1-2-m- SUPER CHLORINATED WATER UNDER SLAB -cLa-cu- SUPER CHLORINATED WATER IN EX. CONDUIT UNDER SLAB -w-w,--- -·---·--- -� ... .,.,, ____ POTABLE WATER EX. POTABLE WATER PIPING TO BE REUSED SODIUM FLUORIDE SODIUM FLUORIDE !N EX. CONDUIT SODIUM PERMANGANATE SODIUM PERMANGANATE IN EX. CONDUIT -�,._,.,.._ PHOSPHATE - 1-,,_ PHOSPHATE IN EX CONDUIT -- · - • -- CHEMICAL FEED LINES TO REMAIN FOR FUTURE USE MECHANICAL PIPING LEGEND � EXISTING FINISHED WATER MAIN TO REMAIN � EXISTING RAW WATER MAIN TO REMAIN � EXISTING BACKWASH MAIN TO REMAIN PROPOSED FINISHED WATER MAIN .____,I PROPOSED RAW WATER MAIN PROPOSED BACKWASH MAIN PIPE LABEL REQUIREMENTS PIPE MIN LABEL M1N. LETTER DIAMETER SIZE HEIGHT D.75" TO 1.25" 1" X 8" 0.5" 1.25" TO 2.5" 1" X 8" 0.75" 2.5" TO 8" 2"x12" 1.25" 8" TO 10" 3" X 24" 2.5" 10" > 4" X 32" 3.5" CIVIL RENOVATION/ MODIFICATION NOTES 8 0 0 0 CHEMICALLY CLEAN AND PRESSURE WASH WALLS AND CEILINGS. REPAIR EXISTING MORTAR AS NEEDED PAINT WALLS ANO CEILINGS - SEE SPECIFICATIONS EXISTING PIPE TO BE REUSED SHALL BE CLEANED ANO REPAINTED. SEE GENERAL CONSTRUCTION SPECIFICATIONS. ALL NEW DUCTILE IRON PIPINGNALVES AND APPURTENANCES SHALL BE PAINTED. SEE GENERAL CONSTRUCTION SPECIFICATIONS. CHEMICALLY CLEAN, PRESSURE WASH AND RESEAL FLOOR AND CONCRETE PEDESTALS. NOTE, DISINFECTION OF THE INTERIOR PIPING, FITTINGS, VALVES AND PUMPS SHALL BE IN ACCORDANCE WITH AWNA C653 REQUIREMENTS AND ANY NECESSARY FIELD DECHLORINATION SHALL BE COMPLETED IN ACCORDANCE WITH AVWvA C655. EXISTING 6'' FINISHED WATER EFFLUENT EXISTING PLANT No. 1 - PROCESS PIPING SECTIONS REVISIONS BID SET C 2023 Midwtsicrn Engint'er.s. Inc. 802 Wt'.sl Broadway Sll\'d P.O. Bm 295 Loogwtee. lmli,ma 47553 DATE NOV. 2023 DESIGN J.W.W. DRAWN M.M.C.!'K.J.G. Q.C. CHECK PROJECT NUMBER 2017043-01 M1 .03 28 OF 47 I FILE NUMBER I 43643 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2