BUILDING WALL MAINTAIN CLEARANCE PER CENTERPOINT 00 TOP VIEW METER SOCKET >,r--r BUILDING WALL MOUNTED METER SOCKET BUILDING WALL / f u f CURRENT TRANSFORMERS___ _u___"___ _"_--f�o;if"::ofl SUPPLIED & INSTALLED / 1 1 / 1 1 BY CENTERPOINT / 1 1 ' ' Oo I I f<) in ,.---li-����--f4-r--1J.... � I I -----t ·.j 1 1 1 1 11 1 · • I �· ����::� :�:-�-' �� · ------11 NOTE, METER SOCKET SUPPLIED BY CENTERPOINT & INSTALLED BY CONTRACTOR, LESS THAN 15' FROM TRANSFORMER. METER SUPPLIED & INSTALLED BY CENTERPOINT. PROVIDE AND INSTALL PROVIDED & INSTALLED BY CONTRACTOR TO J 1 Y, " CONDUIT FOR METERING J I l l CONDUIT AND WIRE CONTRACTOR. 8'-0" PER PROPOSED ONE MIN. LENGTH DRIVEN GROUND Y , "¢ COPPERWELD OR EQUIVALENT w/ WIRE BY CONTRACTOR LINE DIAGRAM S I DE VI EW CONTRACTOR TO EXTEND 4" SCH. 40 1 PVC CONDUIT--� w/ LONG SWEEP ELBOWS, PULL ROPE AND 42" I I I • TO BACKWASH PUMP CONTROL PANEL, COVER FROM PROPOSED PRIMARY POWER POLE TO "I PAD MOUNT TRANSFORMER. SEE SITE PLAN AND ONE LINE DIAGRAM FOR MORE INFORMATION • PROPOSED ELECTRIC FIELD VERIFY TRANSFORMER LOCATION-- - w/ CENTERPOINT AND OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION, MAINTAIN CLEARANCES. GROUNDING ELECTRODE SYSTEM, SEE ONE LINE DIAGRAM FOR MORE INFORMATION FIELD VERIFY GENERATOR LOCATION-----! w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION, MAINTAIN CLEARANCES. PROPOSED TRANSFORMER SEE DETAILS THIS SHEET E METER, WIRING AND METERING BY CENTERPOINT MIN. 6' -----< < (4) #600 MCM THWN, A , 4" SCH. 80 PVC MIN. 10' CONDUIT w/ LONG SWEEP ELBOWS AND 24" COVER I I PROPOSED 4DDA-3P SERVICE ENTRANCE RATED, DELAYED TRANSITION, AUTOMATIC TRANSFER SWITCH I I (4) #500 MCM THWN (1) #3 GU. GND. 4" CONDUIT C /HIG PU ' ERVICE #1 VFD < HIG ERVICE (INTAKE) PROPOSED 230KW DIESEL STANDBY GENERATOR (EXHAUST) CONCRETEJ GENERATOR PAD PU #2 VFD A-8 BATTERY CHARGER 11 I A-9 BLOCK HEATER .. SAW CU CONDUIT THEN R PRE-DIS CONDITI MIN. 4' PROPOSED LOOR FOR STALLATION, ORE TO RBED FINISHED WATER METER IN VERTICAL I I I WELL #2 MOTOR STARTER WELL #3 MOTOR STARTER I WELL #1 I I • • MOTOR STARTER WELL #4 MOTOR STARTER WELL #5 MOTOR STARTER INTERLOCK TO EXHAUST FAN I:) I A-26,28,30 8-14,16,18 UH-4 A-14 I A-23,25,27 1-----PROPOSED PANEL "A" MDPA-2,4,6 A-29,31,33 8-15,17,19 A-2 D D D D CHLORINE ROOM EF-0 - ------WEATHERPROOF, VANDAL RESISTANT l+---PROPOSED 75KVA TRANSFORMER ON 4" CONCRETE HOUSEKEEPING PAD ----- MANUAL LIGHT SWITCH w/ PILOT LIGHT, 48" A.F.F. (TYP.) 1-----PROPOSED MAIN 480V-3¢ DISTRIBUTION PANEL "MDPA" MDPA-7,9,11 "MDPA-8,10,12 ,, ' • • • • • MDPA-25,27,29 PUMP ROOM ----------WEATHERPROOF, VANDAL RESISTANT MANUAL SWITCH FOR EXHAUST FAN w/ PILOT LIGHT, 48" A.F.F. (TYP.) A-2 J j SWITCH FOR LIGHT w/ PILOT LIGHT W----t+---CONTRACTOR TO PROVIDE AND SWITCH FOR EXHAUST FAN w/ PILOT LIGHT INSTALL CHLORINE GAS DETECTION SYSTEM CONTROLLER HIGH SERVICE PUMP #1 4DHP, 48DV-3¢, 52FLA 6" HIGH SERVICE PUMP #2 4DHP, 48DV-3¢, 52FLA \ \ \ ' " ' / / A-10 NOTE, WALL MOUNTED THERMOSTAT WIRING MUST BE RUN IN Jf EMT CONDUIT PER MANUFACTURERS RECOMMENDATIONS 6" A-6 PROPOSED RAW \ WATER METER A-6 0 A-4 IN VERTICAL fr'::� 6" 6" MDPA-26,28,30 DH-2 A-7 AERALATER ROOM #1 GFI A-3 1--f=�PROPOSED PLANT #1 PLC CONTROL PANEL CENTERPOINT ENERGY - SERVICE ENTRANCE DETAILS NOT TD SCALE i MESH REINF . ,- I ' I 0 I n ' 6'-o" . • ' I NO 1. 2. TES, CONCRETE TRANSFORMER PAD 6'x6' w/ 6"x6" MESH REINFORCING. 3. 3500 PSI CONCRETE. CRUSHED STONE AGG. TOP SURFACE TROWEL FINISH. CHAMFER ALL TOP EDGES. SECONDARY CONDUIT MUST BE CONFINED TO SECONDARY AREA. FOR UNEVEN SURFACES SOME ADDITIONAL CONCRETE WILL BE REQUIRED TO STABILIZE THE PAD. I - - ' 0 - �r 2'-6" 1'-8" I SEC. PRIMARY 0 NOTE 2 I 2" ' u -1. 0 'GROUND ROD . ..,__ - ..J - 1'-0" 2'-0" 2'-2" w 1 CHAMFER EDGES � MESH REINF. �;:;;:� l �s==pccz==�s$ ' ' == cj r, =$ r, p=\=fj n fRil='\;;:;m;� , z· ---· 1 I ·-, ·111 l;-rt "' "''-,--'== ·,�_...L-'.'--'-�-,J.--'�---:::._ -�--:-.J._�_J' I I 11 I II I I STD. 4" RIGID ELL---a u 1 uu LJ-1Y," CONDUIT FOR FOR PRI. CABLES METERING PROVIDED AND [ INSTALLED BY CONTRACTOR GROUND ROD CONTRACTOR TO PROVIDE AND INSTALL CONDUIT AND WIRE PER PROPOSED ONE LINE DIAGRAM TRANSFORMER PAD DETAIL NOT TO SCALE ELECTRICAL LEGEND d:f> RECEPT. - OUPLEX J.lGFI (lJ) RECEPT. - GROUND FAULT d:f> RECEPT. - LOCATED ABOVE COUNTER d:f> ! RECEPT. - LOCATED 42" A.F.F. S SWITCH - SINGLE POLE S5 SWITCH - DUAL S 3 SWITCH - THREE-WAY DIRECT CONNECTION cc:::::J DISCONNECT EXHAUST FAN THERMOSTAT @ JUNCTION BOX 8 METER '¢1 FLUORESCENT FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE Q9 EXIT LIGHT '2::3 EMERGENCY LIGHT ELECTRICAL RUN ELECTRICAL RUN - AREAS SWITCHED ----- SEPARATELY WHILE USING SAME CIRCUIT � HOME-RUN TO PANEL ELECTRIC PANEL NOTE, SOME SYMBOLS LISTED UNDER THIS LEGEND MAY NOT BE APPLICABLE TO THIS PROJECT WTP 1 SCALE, -1," - 1'-0" r-:::::1 A-12 L.::_j GFI A-3 GFI LECTRICAL FLOOR PLAN MDPA-19,21,23 -�-.; AERALATER #1---j�'I MOTOR STARTER I \ \ RESTROOM *· [ • u;::: - REVISIONS 11 /8/23 BID SET � 2023 Midwer;tem Engineers. Inc. 802 West Broadway Street P.O. Box 295 Loogootee, Indiana 47553 DATE NOVEMBER 2023 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK J.W.W. PROJECT NUMBER 2017043-01 E1 .01 37 DF 47 FILE NUMBER 43634 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2