Midwestern Engineers, Inc. Plan Preview
• 0 • m m � � N �I = w ;, � a::� - ells: � � "'O � �,,�� = • I Q ,�9 � _Ji.(� �o ...... "Ot � = <!)I!� :: � � � c..o:' � C gg oz =-, OD "6 �- �':' ALUMINUM BLOWER ---- - "-/' ASSEMBLY 1!, HP, 48DV-30 ALUMINUM INOUCED----1 DRAFT AERATOR LEVEL SENSOR CABLING IN CONDUIT TO SCADA, MOUNT 6"-12" ABOVE BOTIOM OF DETENTION TANK � L� CONTROL WIRING (N CONDUIT TO P LA NT �J PLC CONTROL PANEL PER 1/0 LIST 6" INFLUENT--f--•. :!-l j I I J VALVES � (LEVER OP.) ( I I ) I I 8" BACKWASH--+---��'@-., WASTE VALVES \ \ / I / .(_). (GEAR OP . ) CON;ROL WIRING IN CONDUIT TO t LA NT _:_j 0 I PLC CONTROL PANEL PER 1/0 LIST 0 oil C � l- - --------j-Jl -1L -111,-...-------..:0..,L_LOW SUCTION CUTOUT - COMPOUND VACUUM" GAUGE 28" HG. TO 15 PSI w/ LOSS OF HEAD GAUGE FACE TO BE FIELD LOCATED INSIDE THE WTP. MERCOID VACUUM LIMIT SWITCH 1O" HG VAC TO 12 PSI TO BE FIELD LOCATED INSIDE THE WTP AERALATER DETAIL NOT TO SCALE TYPICAL OF TWO SWITCH TO SCADA ' . ' . ' �E- E-E- PROPOSED TRANSFORMER ' PROPOSED 400A-3P SERVICE ENTRANCE RATED, DE LA YED TRANSITION, AUTOMATIC TRANSFER SWITCH I I CONTROL WIRING IN CONDUIT TO P LA NT #1 PLC CONTROL PANEL PER 1/0 LIST ./--ie, / < / ,. ,-. / /HIG , // PU :,� HIG SERVICE � / / / #1 VFD ERVICE - - I WELL #2 MOTOR STARTER WELL #3 MOTOR STARTER I I I I I I I I WELL #4 MOTOR STARTER _,,-[ L.....'ii'-J I I I IL --'i'-- I_J WELL #1� MOTOR STARTER I ., I 1-----PROPOSED PANEL "A" CONTROL WIRING IN CONDUIT TO P LA NT #1 & #2 PLC CONTROL PANELS PER 1/0 LIST WELL #5 MOTOR STARTER I' .,'.///,'/'/// /l CHLORINE ROOM CHLORINE INJECTORS 1. WTP2-POST 2. WTP2-PRE 3. WTP1-POST 4. WTP1-PRE ( INTRUSION A LA RM TO SCADA g::::: CONTROL WIRING IN CONDUIT �TO P LA NT #1 & #2 PLC g CONTROL PANELS PER 1/0 LIST I I I / CONTROL WIRING IN CONDUIT CHLORINE SCALE--t--t-� '- L / TO P LA NT #1 PLC CONTROL H---PROPOSED 75KVA TRANSFORMER ON 4" CONCRETE HOUSEKEEPING PAD 0 - PANEL PER 1/0 LIST f'JE HORN RED LIGHT & HORN FOR GAS DETECTION SENSOR b::RED - - -WIRE TO SCADA PANEL - - !----PROPOSED MAIN DISTRIBUTION PANEL "MDPA" PUMP ROOM I �'--- ---------� CONTROL WIRING IN CONDUIT TO PLANT #1 PLC CONTROL PANEL PER 1/0 LIST -H-- -CONTRACTOR TO PROVIDE AND INSTALL CHLORINE GAS DETECTION SYSTEM CONTROLLER PER MANUFACTURERS RECOMMENDATIONS � CONTROL WIRING IN CONDUIT TO PLANT #1 PLC CONTROL PANEL PER 1/0 LIST • ---=-- • � HIGH SERVICE PUMP #1 m m m1111 m m 11116" 111 I --- --- '- / ' / ' / \ I \ I V I � INTRUSION A LA RM TO SCADA PROPOSED PLANT #2---1 PLC CONTROL PANEL '�-----. �/;/' PU #2 VFD � t � 6 'H" E'=e \ \ ETHERNET TO SCADA � • ' ' . . . ' -""' PROPOSED 23DKW DIESEL STANDBY GENERATOR ' . . . .. . 6 " DIS �RGE --........ c;;: m m 1111 Ill PRE URE .........__ 1� m TRA DUCER ------t�;:::'-jl); 1 A:li:IIK l lsffi-ill+ - - • • 6 " � HIGH SERVICE PUMP #2 ,=a m 61t Ill D - ' ' / I / / ENTRY/LAB PER 1/0 LIST -�---< ii�;;;-i-+--HIGH SERVICE CONTROL WIRING IN � PUMP #3 VFD CONDUIT TO P LA NT #2 :, r--:� PLC CONTROL PANEL r--@ >--+---HIGH SERVICE CONTROL WIRING IN CONDUIT TO SCADA PER 1/0 LIST 'K:t • • CONTROL WIRING IN CONDUIT TO P LA NT 6 " #1 PLC CONTROL PANEL PER 1/0 LIST E ==a / ETHERNET TO SCADA I PER 1/0 LIST PER 1/0 LIST PUMP #4 VFD - >--+---PROPOSED PANEL "8'' � � - ' 0 FIBER TO BACKWASH \.r, PUMP CONTROL '- <el - - CONTROL WIRING IN ::��"' PANEL PER 1/0 LIST --@ CONDUIT TO P LA NT #1 PROPOSED-----+-+-HIO PLC CONTROL PANEL 6" 6 • PROPOSED PLANT #1---1 FINISHED WATER - PER 1/0 LIST /'== 3 PLC CONTROL PANEL MEIER IN VERTICAL ' '+ '= --+"----------'--1---l----e---e------� I / I CONTROL WIRING IN CONDUIT TO SCADA D LORINE PER 1/0 LIST NALYZER � - I -- ' '\ \ \ I \I / / I -· - >--+---PROPOSED 45KVA TRANSFORMER ON 4" CONCRETE HOUSEKEEPING PAD 6" PROPOSED RAW ./ WATER MEIER IN VERTICAL SODIUM /.: PERMANGAN!,TE ;:. DAY TANK LEVEL TO P LA NT #2 . ®Y7 PLC CONTROL PANEL CONTROL WIRING IN CONDUIT TO P LA NT #2 PLC CONTROL PANEL PER 1/0 LIST DISCHARGE PRESSURE TRANSDUCER � ? r,;.; I � 1// I / ;;; e'.-L _.. v-::::: ----- '- '- I - - 8' I ) "'- ce m 1116" / 8 ' �/ I 1116" ( B ' 1116" 8" � /\ 1116' w - m rS� 'Si' 3 " � m m IIIAIII w w � 6" � AERALATER ROOM #1 " · . . TANK LEVEL TO PLANT ,----7�::::--:::v·fc"'. #2 PLC CONTROL PANEL 2oN�lG IJ..CONDUIT CONTRACTOR TO FIELD VERIFY --;y---TO P LA NT #1 & #2 PLC LOCATION OF DAY TANK PROPOSED SODIUM---t--i l <e' A<I J CONTROL PANELS PER 1/0 LIST SCALES, WIRE TO SCADA PERMANGANATE 1-J! I '>--,/ I ,•..·· TERMINAL BOX ,·· ' .. "'1 • ·.• -t .., • . . ' ·) -, .• � --'- "'--'-�----, . · DAY TANK LEVEL HIGH SERVICE PUMP #3 m m m - Ill Ill 1111 W C a w w E ==e C a Eee3 - - E'ee3 /" PROVIDED BY INTEGRATOR THEN INSTALLED BY ONTRACTOR • TO P LA NT #2 PLC � , �� CONTROL PANEL ..__, E eee3 HIGH SERVICE PUMP #4- - ��d----"'")� __J PHOSPHATE ' TANK LEVEL TO P LA NT " / #2 PLC CONTROL PANEL PROPOSED�:;:::::;;-;:--t--J�, .JL ./ PHOSPHATE TERMINAL �, 1/m"':"' ��, , w ,: CONTROL WIRING IN "co "' N "' D "' u'·r- T TO PLANT #1 & #2 PLC CONTROL PANEL PER 1/0 LIST BOX PROVIDED BY - INTEGRATOR THEN INSTALLED BY ,_ ______ ___,. . . •· � . :.-:·· ',:"·-_._·::.·.·�··: :; ' •' ]7"" PROPOSED SODIUM FLUORIDE \ TERMINAL BOX PROVIDED BY INTEGRATOR THEN INSTALLED / BY CONTRACTOR \ 0 00 M Eee3 / PROPOSED � _../ FINISHED WATER MEIER CONTROL WIRING IN ;- CONDUIT TO P LA NT M #2 PLC CONTROL � PANEL PER 1/0 LIST Ecc 3 -----------� -L...lf-.L-� -------- ea "' ---1 I /"s Ec=a � C � ,=a ''=3 - /� I"--"- 3" •I ------ /l.,.,,--"" -........., � - -------�<CONTROL WIRING IN CONDUIT (� ltl ) ) > TO PLANT #1 PLC CONTROL � PANEL PER 1/0 LIST lie, AERALATER #1 MOTOR STARTER---! - I w \ 0 • / \ I \ \ RESTROOM ... r r 0 � -. ,/ CONTROL WIRING IN CONDUIT TO P LA NT #1 & #2 PLC CONTROL PANEL PER 1/0 LIST - SODIUM FLUORIDE ,:= M e,=a 10 CONTROL WIRING IN CONDUIT TO P LA NT #2 PLC CONTROL PANEL PER 1/0 LIST \� PROPOSED RAW WATER FLOW MEIER WTP - CONTROLS FLOOR PLAN SCALE, %" � 1' -0" I I CONTROL WIRING IN CONDUIT TO P LA NT #2 PLC CONTROL PANEL PER 1/0 LIST AERA LA TER #2 MOTOR STARTER - AERALATER ROOM #2 .� ��===========================================================================================================================================================================================================================================================================================================:] • u § " t: s * u N t; ·c - 5 • " C 0: � i ' i:il 00 "" i Jz "I ;.; ';, -. � V pl ,.:, C -- ' 0 V - ! • g o,:_,: � " e �j "" 0 t: ' " 0 J C ·2 � •....-4 • ' OJJ N c ii • • " " t: '.:; � ' 0 r �- � ' -� � £ � � t-4 iJ a V g O' ..... tr� � "!: :j! N ' 00 Q ;l � 5 V , ' ;;-.� , � ''" , e- z,... a • 8 t� ' • � 8·;:l"- ;,,; '3 ] .. •" 0 •'I"""'( "'.5 i, u r/l I- w z w w ' <( l � u z w I[ z !!: 0. � � '"" C ... z IC . - � � a. l 0. a: � z ... f-, - z 0 ::::, l w II, -1'. 0 :; u w s � I- r/l I[ w � ... 0 z w LL) w ... IC � � Q. w (/) � ' = � REVISIONS 11/8/23 BID SET IC 2023 Midwes\ern Engineers, Inc. 802 West Broadway Street PO. Box 295 Loogootee, Indiana 47.553 DATI NOVEMBER 2023 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK J.W.W. PROJECT NUMBER 2017043-01 E1 .04 40 OF 47 FILE NUMBER 43631 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2