Midwestern Engineers, Inc. Plan Preview
LENGTH OF STAND x 4' DEEP . : . - .. ·'· : •' .. ···- . . . . , ,. : ·' : �,. .. .. .; '·': . "·· .. ' . ' . .. : ... :. ; ,! : , .... .; . . . .... ' .,I ·• . ·-� -. - ·1 .. . . .. .. . �·,. ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) J," STAINLESS STEEL ALL-THREADS IN CONCRETE ---- -•COMPACTED BACK ' . 12" • �· FILL AROUND BASE (TYP.) J , " ALUM. BASE PLATE BASE DETAIL " ' ' � C , NOT TO SCALE �� --- " --- " "' PROPOSED UNDERGROUND ELECTRIC SERVICE FROM POLE TO METER BASE, SEE RISER THIS SHEET FOR MORE INFORMATION EXISTING POWER POLE BY SOUTHERN INDIANA POWER TO REMAIN - ,� ----- '"' ----- 0.0 -· �--- 0.0 ----- " " OR FOR VICE DITEK SURGE ARREST ELECTRIC SER MODEL D100- MAKE LEADS AND STRAIGH POSSIBLE. 120/2401. AS SHORT T AS METS ON PROVIDE GROM KNOCKOUTS T WIRE INSULATI 0 PROTECT ON GFCI RECEPTACLE � ...- - - NEMA 4X S.S. w/ HASP AND SIZED BY CON ENCLOSURE ------...__ STAPLE c TRACTOR BACK PANEL � ...- ' PANOUIT ORE !]U.!RE D QO ADCKlfflR OR EQUAL HMJJ. IWN CB BRANCH BREAKERS 50A-2P SURGE ARRESTOR .C- 20A-1P GFCI CONVENIENCE � RECEPTACLE 20A-1P PANEL HEATER 20A-1P SCADA PANEL !c· Jg] � 1','l'P/\NDUITOR CM ,_ THERMOSTATICALLY CONTROLLED CONDENSATION HEATER, HOFFMAN D-AH2001A OR EQUAL ' " �� a "' -,,"', • � .'> ,t o·w '"' ( ;I •, .., ; ' " ,:;., " kc " -cc o, " " ., " " " PROPOSED ELECTRIC SERVICE ENTRANCE, POWER DISTRIBUTION ANO CONTROL STAND BY DIV. 11 CONTRACTOR, COORDINATE LOCATION w/ OWNER/ENGINEER DURING CONSTRUCTION PRIOR TO INSTALLATION. SEE RISER THIS SHEET FOR MORE INFORMATION , ' , ' a j "' " ' ' ' ' ' ' ' ' ' ' "' OOe----- O"S - --- O<e----- O�E ----- OHF------ PROPOSED ELECTRICAL SITE PLAN SCALE, I " � 1O' GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. 2. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL. 3. ALL EXPOSED CONDUITS SHALL BE ALUMINUM, SCH. 80 PVC IF BURIED. TYPICALLY USE LONG SWEEP ELBOWS, MIN. 24" COVER UNLESS OTHERWISE NOTED. 4. ALL OUTDOOR ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL AND HAVE HASP AND STAPLE FOR PADLOCK UNLESS OTHERWISE NOTED. 5. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, PERMITS, OTHER MATERIAL, AND INSTALLATION NEEDED FOR A COMPLETE SYSTEM UNLESS OTHERWISE NOTED. 6. CONTRACTOR TO CONTACT DALE KAUFMAN OF SOUTHERN INDIANA POWER AT 812-719-0549 MIN. 3 WEEKS PRIOR TO COORDINATE ELECTRIC SERVICE INSTALLATION. ALL ELECTRIC UTILITY RELATED FEES TO BE PAID FOR BY OWNER. 7. IT SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE SCOPE OF WORK w/ ELECTRICIAN AND INTEGRATOR PRIOR TO BID. 8. CONDUITS SHOWN ON PLAN ARE FOR REFERENCE ONLY AND ARE NOT NECESSARILY INTENDED TO INDICATE EXACT QUANTITY OR LOCATION. SEPARATE ALL POWER AND CONTROL; SEPARATE ALL DIGITAL, ANALOG, COAX, FIBER OR ETHERNET. PROPOSED 200,000 GALLON WATER STORAGE TANK SCADA NOTES 1. CONTRACTOR SHALL UTILIZE OWNER'S EXISTING SCADA SYSTEM INTEGRATOR BY CONTACTING JEFF BUMGARDNER w/ MAXIM AUTOMATION AT 317-41B-9560 TO PROVIDE SCADA SYSTEM PRICING PRIOR TO BID. PROVIDE AND INSTALL NEW SCADA PANEL w/ THE FOLLOWING FEATURES, A. ALLEN BRADLEY COMPACTLOGIX SERIES PLC w/ 1/0 CARDS AS NEEDED B. 200W ENCLOSURE HEATER C. NEMA 4X S.S. ENCLOSURE D. 500VA UPS BATTERY BACKUP E. PRECISION DIGITAL LEVEL DISPLAY ON DOOR F. SIERRA WIRELESS RV50X CELL MODEM w/ ANTENNA G. REQUIRED INSTRUMENTATION PROVIDED BY INTEGRATOR, INSTALLED BY CONTRACTOR 2. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, WIRING, DEMOLITION AND PROGRAMMING TO ACCOMMODATE THE NEW TANK 1/0 AS NEEDED FOR A FULLY FUNCTIONING SYSTEM. 3 . COORDINATE TAP REQUIREMENTS FOR PRESSURE TRANSDUCER ON TANK LEVEL SENSING LINE w/ DIV. Ill CONTRACTOR. CONTROL WIRE TO BE INSTALLED IN CONDUIT. 4. RTU INPUTS/OUTPUTS DIGITAL INPUTS, RTU POWER FAIL COMMUNICATION STATUS SITE POWER FAIL TANK OVERFLOW (FUTURE) ANALOG INPUTS, TANK LEVEL REO 1-'-lh- -WATER, INC. - ,-"'--,I " NEMA 4X S.S. PULL BOX AT TANK BY DIV. Ill CONTRACTOR • • • • • • • • • • • • CONDUIT STANDOFF BRACKETS TO BE INSTALLED ON LADDER LEG BY DIV. Ill CONTRACTOR METER CROCK AND LID FOR TRANSDUCER/GAUGE CONNECTION w/ SHUT OFF VALVE BY DIV. Ill CONTRACTOR ALUMINUM UNI-STRUT NEMA4X S.S. 30•,30·,s· NEMA4X S.S. 30·,30·,s· EXISTING POWER POLE BY---11 SOUTHERN INDIANA POWER TO REMAIN 4"x4" ALUMINUM ANGLE NEMA 3R, 200A METER BASE PROVIDED BY SOUTHERN INDIANA POWER INSTALLED BY CONTRACTOR CONDUIT AND CABLING---++--11 TO TRANSDUCER BY #4 COPPER IN 1" CONDUIT TO J,\"ox1 o· cu. CLAD GND. ROD INSTALLED BY CONTRACTOR DIV. II CONTRACTOR , ; ... . ... ' . -.,· ·,f;' I ·'-� •'-/.: .. . ] MIN. 42" COVER ·" . •i. ; ;. . . . · BY CONTRACTOR .; '1 . , ·,"J ll·�, =· ';=. !c==!c ============�c!.I -"£ . , • • • •·-.; EXISTING 120 240V-10 OVERHEAO SERVICE BY SOUTHERN INDIANA POWER ·--, ' . • . � ., -... . '·i ... ----o"'=�""""-��������a1=a�-sa=s' ... -· · · ·'· ,. i . . • ,, - - I ' • • � BY DIV. Ill CONTRACTOR . - . � .. �. (3) 2" SCH. BO PVC CONDUITS TO TANK BY DIV. Ill CONTRACTOR 42" TRENCH, COVER, RESTORATION AND SPENCER COUNTY ELECTRIC PERMIT BY CONTRACTOR. SIP TO PROVIDE AND INSTALL CONDUIT AND WIRE FROM METER BASE LOCATION TO TOP OF SERVICE POLE. METER BASE w/ LEVER BYPASS PROVIDED BY SIP INSTALLED BY CONTRACTOR, METERING BY SIP. GROUNDING WIRE, ROD AND CONDUIT BY CONTRACTOR PER SIP INSTALLATION REQUIREMENTS. PROPOSED 200,000 GALLON WATER STORAGE TANK ELECTRICAL RISER NOT TO SCALE • - REVISIONS 11/8/23 BID SET C 2023 Miclweslt'm Engineers. Inc. 802 We�\ Bnxulway Street P.O Box 29. '\ l.oogoo1ee. Indiana 47553 DATE NOVEMBER 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK J.W.W. PROJECT NUldBER 2017043-01 El.06 42 DF 47 I FlLE NUMBER I 43629 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2