Midwestern Engineers, Inc. Plan Preview

EXISTING 50,000 GALLON WATER STORAGE TANK #2 SCADA NOTES 1. CONTRACTOR SHALL UTILIZE OWNER'S EXISTING SCADA SYSTEM INTEGRATOR BY CONTACTING JEFF BUMGARDNER w/ MAXIM AUTOMATION AT 317-418-9560 TO PROVIOE SCADA SYSTEM PRICING PRIOR TO BID. EXISTING SCADA PANEL TO BE REMOVED AND NEW TO BE INSTALLED w/ THE FOLLOWING FEATURES: A. ALLEN BRADLEY COMPACTLOGIX SERIES PLC w/ 1/0 CARDS AS NEEDED B. 200W ENCLOSURE HEATER C. NEMA 1 ENCLOSURE, FIELD VERIFY CONTROL PANEL WIDTH PRIOR TO INSTALLATION SO THAT NEW FITS WHERE EXISTING IS LOCATED D. 500VA UPS BATTERY BACKUP E. PRECISION DIGITAL LEVEL DISPLAY ON DOOR F. SIERRA WIRELESS RV50X CELL MODEM w/ ANTENNA G. REQUIRED INSTRUMENTATION PROVIDED BY INTEGRATOR, INSTALLED BY CONTRACTOR 2. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, WIRING, DEMOLITION AND PROGRAMMING TO ACCOMMODATE THE TANK 1/0 AS NEEDED FOR A FULLY FUNCTIONING SYSTEM. 3. COORDINATE REQUIREMENTS FOR PRESSURE TRANSDUCER ON TANK LEVEL SENSING LINE. EXISTING SENSING LINE TO REMAIN, INSTALL MAIN SHUT OFF VALVE, CROSS w/ GAUGE, AIR RELIEF AND TRANSDUCER CONNECTION AS INDICATED. 4. RTU INPUTS/OUTPUTS DIGITAL INPUTS: RTU POWER FAIL COMMUNICATION STATUS SITE POWER FAIL TANK OVERFLOW (FUTURE) MERSIBL!s PRESSURE SUB 'rRA NSoucrn I SSURE GAUGE EQUAL PRE ro ASHCROFT 1009 BALL VALVE EQUAL TO 14" NIBC0 T-585-80-LF ANALOG INPUTS: TANK LEVEL (INSIDE BUILDING) SCADA PANEL l - � .. = MANUFACTURER FURN!SHED CABLE, CONTINUOUS LENGTH (NO SPLICES) I J\" MIP BRASS SMOOTH NOSE SAMPLE FAUCET ' LEGEND VALVE T-532 " 4 NL-Y. I CONTRACTOR TO INTE EXISTING TANK LEVEL SENSING LINE, THEN I LL RCEPT NSTA w/ NEW SHUTOFF VALVE GAUGE, VALVE AND TRANSDUCER AS INDICATED PRESSURE TRANSDUCER DETAIL NOT TO SCALE � � ' -� I \ .. . /fp I " ' ' ' ' REO WATER, "'"' � ' ��\ " ' ' ' ' -, ' -,-- " ' \\� \ I INC. f. n , __ ' = Jd/ = J "' .:. ,/ = ' ; A = = � : - ' . ,, ' ' = ' R = = . ' ' ' f ' = -- EXISTING TO -<Ec:----1,------1 BE REMOVED // D ' [ - -- Q G \lln EXISTING TANK LEVEL j SENSING LINE TO REMAIN GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. 2. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL. 3. ALL EXPOSED CONDUITS SHALL BE ALUMINUM, SCH. 80 PVC IF BURIED. TYPICALLY USE LONG SWEEP ELBOWS, MIN. 24" COVER. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, OTHER MATERIAL, AND INSTALLATION NEEDED FOR A COMPLETE SYSTEM UNLESS OTHERWISE NOTED. 5. IT SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE SCOPE OF WORK WITH ELECTRICIAN AND INTEGRATOR PRIOR TO BID. 6. CONDUITS SHOWN ON PLAN ARE FOR REFERENCE ONLY AND ARE NOT NECESSARILY INTENDED TO INDICATE EXACT QUANTITY OR LOCATION. SEPARATE ALL POWER AND CONTROL; SEPARATE ALL DIGITAL, ANALOG, COAX, FIBER OR ETHERNET. 7. CONTRACTOR IS RESPONSIBLE FOR REMOVING EXISTING POWER AND CONTROL EQUIPMENT AS REQUIRED TO UPGRADE PROPOSED SCADA RTU. THIS SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO EXISTING SCADA CONTROL PANEL, ANTENNA, COAX CABLING, DIGITAL CONDUIT/WIRE, ANALOG CONDUIT/WIRE, ETC. OWNER RESERVES FIRST RIGHTS TO ALL REMOVED EQUIPMENT. ALL UNWANTED MATERIAL SHALL BE DISPOSED OF BY THE CONTRACTOR PER FEDERAL, STATE AND LOCAL REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. (( ( \\\\ \\ \ \ EXISTING RADIO ANTENNA, COAXJ ... r.::'\ EXISTING 1201240V 10 '"1111.!I ELECTRIC SERVICE BY CONDUIT AND APPURTENANCES CENTERPOINT TO REMAIN TO BE REMOVED BY CONTRACTOR 11/0l 11141 I I 11 I I I I I II II II I II II " II II II II 111/41 ' """ SCADA CONTRACTOR TO PROVIDE AND PANEL INSTALL PROPOSED TANK #2 SCADA CONTROL PANEL, REMOVE EXISTING SCADA EQUIPMENT IN ITS ENTIRETY NEMA 4X S.S. 30"x30"x8" LONTRACTOR TO INTERCEPT EXISTING TANK LEVEL SENSING LINE, THEN INSTALL NEW SHUTOFF VALVE w/ GAUGE, VALVE AND TRANSDUCER AS INDICATED EXISTING 8 CKT. QO LOAD CENTER TO REMAIN, MODIFY AS REQUIRED EXISTING METER ' ",,, AND DISCONNECT ,m::: TO REMAIN 111�1 \J \J II/Ml EXISTING SCADA CONTROL PANEL EXISTING 50,000 GALLON WATER STORAGE TANK #2 ELECTRICAL RISER NOT TO SCALE • - REVISIONS 11/8/23 BID SET C 2023 Midwc.it�rn Engineers. Inc. 802 Wco1 llrnadway Street P.O. llox 295 Loogootee. lndianu 4755) DATE NOVEMBER 2023 DESIGN A.F.B. DRAWN C.N.M. Q.C. CHECK J.W.W. PROJECT NUMBER 2017043-01 El.07 43 OF I � LE NUMBER . 43628 47 I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2