Midwestern Engineers, Inc. Plan Preview
GENERAL MECHANICAL NOTES THESE DRAWINGS INDICATE REQUIRED SIZES AND POINTS OF TERMINATION FOR PIPING, DUCTWORK, CONDUIT, ETC. THE EQUIPMENT SHOWN ILLUSTRATES SUGGESTED ROUTING, BUT ALL NECESSARY OFFSETS AND FITIINGS MAY NOT BE SHOWN. CONTRACTOR SHALL INSTALL HIS WORK IN A MANNER THAT WILL CONFORM WITH THE STRUCTURE. CONTRACTOR SHALL AVOID OBSTRUCTIONS, PRESERVE HEADROOM AND MAINTAIN MAXIMUM CLEARANCE WITHOUT FURTHER INSTRUCTION FROM THE ENGINEER OR ADDITIONAL COST TO THE OWNER. ALL DIMENSIONS SHOWN ON THESE PLANS ARE IN FEET AND/OR INCHES UNLESS NOTED OTHERWISE. EQUIPMENT SIZES AND SERVICE SPACE REQUIREMENTS MAY VARY BETWEEN DIFFERENT MANUFACTURERS. CONSULT APPROVED MANUFACTURER DRAWINGS AS SUBMITIED, AND COORDINATE WITH THESE DRAWINGS. ALL EQUIPMENT SHALL BE OF, AND CONSIST OF AT LEAST THE MINIMUM SIZES SCHEDULED. ALL EXISTING EQUIPMENT, DUCTWORK AND PIPING LOCATIONS AND SIZES SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION BY THE CONTRACTOR. ALL VALVES, COILS, DAMPERS, ETC. SHALL BE INSTALLED ALLOWING EASY ACCESS. AREAS ADJACENT TO THE ACCESS PANELS SHALL BE CLEAR OF ANY OBSTRUCTIONS. ALL WALL THERMOSTATS SHALL BE APPROXIMATELY 4'-6" ABOVE FINISH FLOOR TO BOTIOM AND LINED UP HORIZONTALLY WITH LIGHT SWITCHES UNLESS OTHERWISE NOTED OF DIRECTED BY THE ENGINEER. THERMOSTATS IN PUBLIC AREAS SHALL HAVE LOCKING COVERS. CONTROLS ANO SEQUENCE OF OPERATION SHALL BE AS INDICATED ON DRAWINGS. PROVIDE A MINIMUM OF 1o·-o" FROM ANY EQUIPMENT ANO PLUMBING VENTS FROM ALL OUTSIDE AIR INTAKES, DOORS, OR OPERABLE WINDOWS. REFER TO MECHANICAL SCHEDULES AND DETAILS FOR ADDITIONAL EQUIPMENT REQUIREMENTS. EACH RESPECTIVE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE INSTALLATION OF HIS WORK WITH THE WORK OF OTHER CONTRACTORS PRIOR TO THE INSTALLATION. REFER TO ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL COORDINATION WITH THESE DRAWINGS. CONTRACTOR SHALL NOT LOCATE ANY DUCT OR PIPING DIRECTLY OVER ANY ELECTRICAL PANELS, SWITCH GEAR, TRANSFORMER, ETC. COORDINATE LOCATIONS OF DUCTS AND PIPING WITH THE ELECTRICAL CONTRACTOR TO AVOID THESE CONFLICTS. ALL HVAC SYSTEMS SHALL BE WIRED BY THE ELECTRICAL CONTRACTOR ANO SHALL BE PLACED ON A DEDICATED CIRCUIT. SERVICE SPACE FOR EQUIPMENT SHALL NOT BE BLOCKED WITH PIPING, DUCTWORK, ETC. DUCTS PENETRATING ROOF, FLOOR SLABS AND/OR WALLS SHALL BE SEALED AS REQUIRED BY CODE. DUCTS PENETRATING HAVE OPENING AROUND DUCT SEALED WITH A MATERIAL HAVING THE SAME FIRE RATING AS THE WALL OR FLOOR. FIRE RATED WALL AND/OR FLOOR SHALL HVAC EQUIPMENT SCHEDULE UH-1 REZNOR - ELECTRIC UNIT HEATER MODEL# EUH-TSL10, OR EQUAL BY MARKEL, MODINE 480V-3•, 12.2A, 10KW, 34,121 BTUH, 957 CFM BA6 LOCKABLE, NON-FUSED DISCONNECT CL1 SINGLE STAGE THERMOSTAT UH-2 REZNOR - ELECTRIC UNIT HEATER MODEL# EUH-TSL05, OR EQUAL BY MARKEL, MODINE 480V-3•, 6.7A, 5KW, 17,060 BTUH, 479 CFM BA6 LOCKABLE, NON-FUSED DISCONNECT CL1 SINGLE STAGE THERMOSTAT UH-3 REZNOR - ELECTRIC FAN FORCED WALL HEATER MODEL# EHC-TSL, OR EQUAL BY QMARK 120V-1o, 1,500W, 5,125 BTUH, 160 CFM HK1 WHITE CABINET COLOR UH-4 D.1\Y' TON - ELECTRIC CONVECTION HEATER HVAC PLAN NOTES (i) 0 0 EXTEND 6" EXHAUST THRU EXTERIOR WALL AND TERMINATE WITH MANUFACTURER FURNISHED WALL CAP. SEAL PENETRATION WITH SPRAY FOAM INSULATION AND EXTERIOR CONSTRUCTION SEALANT BEHIND PERIMETER FLANGE. INSTALL UNIT HEATER WITH BOTIOM 12" ABOVE FLOOR. UNROLL MANUFACTURER FURNISHED CONDENSATE TUBING AND TERMINATE OVER FLOOR PIT/DRAIN. INSTALL UNIT HEATER WITH BOTIOM 10'-Q" ABOVE FLOOR. MOUNT WITH 3/8" THREADED ROD TO THE ROOF TRUSS. INSTALL AIR HANDLER FLUSH WITH CEILING. SECURE TO STRUCTURE ABOVE PER MANUFACTURER'S REQUIREMENTS. INSTALL LINESET AND CONDENSATE DRAIN ABOVE LAY-IN CEILING. EXTEND THRU EXTERIOR WALL AND SEAL WITH SPRAY FOAM INSULATION AND EXTERIOR CAULK. MODEL# 3VU33B, 120V-1 o CORD AND PLUG, OR EQUAL BY QMARK CD ® ® 0 SECURE LINESET AND CONDENSATE DRAIN TO EXTERIOR WALL. TERMINATE DRAIN 6" ABOVE GRADE. EXTEND LINESET TO HEAT PUMP AND MAKE FINAL CONNECTIONS PER MANUFACTURER'S REQUIREMENTS. HP-1 TRANE - HEAT PUMP OUTDOOR UNIT MODEL# TRUZA0121KA70NA, OR EQUAL BY MITSUBISHI 2osv-1 •. 11 MCA, 1,590 CFM AH-1 TRANE - CEILING AIR HANDLER MODEL# TPLAOA0121EA70A, OR EQUAL BY MITSUBISHI 208V-1o, 1 MCA, EF-1 GREENHECK - ROOF DOWNBLAST EXHAUST FAN MODEL# G-095, OR EQUAL BY COOK EF-2 640 CFM @ 0.25", 1300 RPM, 1/12 HP BD-1DO EXHAUST DAMPER, 1O"x1O" GREENHECK - BATHROOM CEILING EXHAUST FAN MODEL # SP-B110ES-QD, OR EQUAL BY BROAN 115 CFM @ 0.125" TOTAL EXTERNAL S.P. 30 WAITS, 120V-1•. INTERLOCKED w/ LIGHTS WC-6 ROUND HOODED WALL CAP L-1 GREENHECK - LOUVER MODEL# ESD-435, OR EQUAL BY RUSKIN 24"x24" DOUBLE FLANGE FRAME ASSEMBLY VCD-23 VOLUME CONTROL DAMPER, 24"x24" DH-1 QUEST - DEHUMIDIFIER MODEL# HI-E DRY 195, OR ENGINEERED APPROVED EQUAL 195 PINTS, 120V-1 ¢, 13.1A, 610 CFM DH-2 QUEST - DEHIMIOIFIER MODEL# HI-E ORY 100, OR ENGINEERED APPROVED EQUAL 106 PINTS, 120V-1¢, 6.6A, 225 CFM 0 0 @ @ @ @ INSTALL HEAT PUMP ON 6" CONCRETE PAD. 10"x10" EXHAUST UP TO ROOF MOUNTED EXHAUST FAN ( EF-1 ) . TERMINATE 1 O"x1Q" EXHAUST RISER 6" ABOVE FLOOR WITH GRILLE. OFFSET HORIZONTALLY AS HIGH AS POSSIBLE. MOTOR RATED MANUAL SWITCH FOR EXHAUST FAN WITH PILOT LIGHT. MOUNT AT 48" ABOVE FLOOR. WEATHERPROOF, VANDAL RESISTANT, MOTOR RATED MANUAL SWITCH FOR EXHAUST FAN WITH PILOT LIGHT. MOUNT AT 48" ABOVE GRADE. INSTALL LOUVER IN TOPMOST CORNER OF EXISTING WINDOW OPENING. REMAINDER OF OPENING TO BE INFILLED WITH CONCRETE BLOCK. COORDINATE WITH STRUCTURAL DRAWINGS. INLET FILTER/SILENCER AIR FILTER w/ SPARE CARTRIDGE (TYP.) AUTO DRAIN ASME SAFETY VALVE 0 DUPLEX COMPRESSOR MANUAL TANK DRAIN 120V AUTOMATIC TANK DRAIN (A-19) 0 TO FILTER .u--VALVES TO FILTER .u--VALVES BYPASS VALVE BYPASS VALVE IRGP40 PREFILTER WATER TRAP DESIGN DROP TO COME OFF TOP OF AIR HEADER TO FILTER il"-VALVES TO MANUAL DRAIN, TYP. OF EACH DROP DETAIL -A NOT TO SCALE WATER TRAP/L_J 3" SLOPE __ {__ A-17 DRY COMPRESSED AIR TO DISTRIBUTION SYSTEM NOTE: ADD DRAINLINE FOR COMPRESSOR/DRYER TO NEAREST DRAIN f-- - PUMP ROOM I D D D D CHLORINE ROOM ' I , - 1r • �6·ii ITT .., - � - IL ' 11 ENTRY/ LAB E w I 6" -· ' a,; m ITT ITT a IIIUIIII Ill E ='$ w w ill ii Ill w � • • • 1F � w • • '-- - - - - 16" *'� cp I I�--- UH-2 ' £ ;::: ;;a · DH 2 6" ' 0 ,aaaa � Eaaa:a - 6' 111ml' - - E ' ,= 6' ,., •., :a / CONTROL WIRING IN CONDUIT ( TYP.) -<Tl T ,-+ I J �==GfF==ffu ====©0 � u;)�:1 � : "'.. --._� 0 E ,ea 3 \ I ' I \ ' " I / I / / I �r-.._ - �» ---'=- - "'-- r--,-r 1- ..L-- -_____;___i_� AERALATER ROOM #1 ' I / >- - �6' .. 8" // I I'" I / 111,· / I c -1 I 8" ml _ .. � 0 � I // / , ,,/ �----------�' ... ' ' [) I I \01 RESTRorn ' ' llJ 2 _(l 0 - 11 / '",,,; I f-- --+- - -·t,'-,---t -r'-;---. :f' �1 - - - n ,'l I ( / C. - � - 0 00 - I_ / I I ' I I 1 1 1· I 11 I \ I I Tl II E ,= :a ,== � v� v I E� :a � ....________ ,__ � � == a E =:a � ITT . I --------0 111 )i( Ill --------, cp '- - - -�-�. --� _ _ ' _ ____ __________________ I DH-1 I _ _ _� 0 WTP HVAC PLAN SCALE: 'Ja" - 1'-0" REVISIONS 11/8/23 BID SET C 2023 1',folwestem Engineers. Inc. 802 We.It Broadway Street P.O. Box 295 UJogootce. lndifin;, 47553 DATE NOVEMBER 2023 DESIGN A.F.B. DRAWN C.N.M. a.c. CHECK J.W.W. PROJECT NUMBER 2017043-01 MH1 .01 45 OF 47 I Fll£ NUMBER I 43626 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2