Midwestern Engineers, Inc. Plan Preview
REMOTE SENSOR INSTALLED IN LID WITH DRILLED OPENING. HIGH STRENGTH POLYPROPYLENE FRAME & COVER SET FLUSH WITH GROUND SURFACE ANCHOR LUGS - ------ , ✓ 1 HOPE PIT WITH REINFORCED RIBS WITH NOTCHES FOR SERVICE LINE AS MANUFACTURED BY FRANCESVILLE DRAIN TILE (FRATCO) CORP. COMPACTED CLAY OR LOAMFILL AROUND PIT 1 112" METER COPPER SETTER WITH �� PRESSURE REDUCING VALVE. SEE SPECIFICATION FOR TYPE AND ACCESSORIES REMOTE SENSOR INSTALLED IN LID WITH DRILLED OPENING 13-3116" I • 20" FOR SIB ) & 3/4"METERS 24" FOR 1" METERS z " 13-3116" I • 20" FOR 518" & 314" METERS 24" FOR 1" METERS METER (SEE SPECS) REMOTE SENSOR INSTALLED IN LID WITH DRILLED OPENING. HIGH STRENGTH POLYPROPYLENE FRAME & COVER SET FLUSH WITH GROUND SURFACE C------ HOPE PIT WITH REINFORCED RIBS WITH NOTCHES FOR SERVICE LINE AS MANUFACTURED BY FRANCESVILLE DRAIN TILE (FRATCO) CORP. COMPACTED CLAY OR LOAM FILL AROUND PIT CORP. STOP MODEL 470BT WITH INSERT STIFFENER MODEL 6133T BY AY McDONALD MFG. CO. 1 1/2" ¾" x 1" INCREASER MAIN---\ □ ¾"HOPE, SDR-9 CTS 13 3116" ¾" HOPE, SDR-9 CTS 1" HDPE, SDR-9 CTS _______..,,__-IJ:.:: ------ ¾" x 1" INCREASER "Y" COUPLING WITH INSERT STIFFENERS DOUBLE METER SETTING 2" HOPE, SDR-9 CTS NOTE: SADDLES REQUIRED ON ALL MAINS PER SPECIFICATIONS HOLLOW COPPER TUBE TERMINAL TEST ACCESS POINT I---+- INSERT TRACER WIRE � INTO TUBE AND CRIMP NOTE: CONTRACTOR SHALL BE REQUIRED TO PROVIDE PHOTOGRAPHS OF THE FIELD TILE REPAIR (BOTH PRIOR TO AND AFTER REPAIR) PRIOR TO EARTH LOAM BACKFILL. THE CONTRACTOR SHALL PROVIDE A LABELED 3-RING BINDER CONTAINING THE REQUIRED PHOTOGRAPHS. EACH PHOTOGRAPH SHALL BE PROPERLY LABELED WITH THE PROPER STATIONING, SIZE OF TILE REPAIR, DATE OF REPAIR AND PROPERTY OWNER. EXISTING FIELD TILE FERNCO ADAPTER INSTALLED EACH SIDE OF FIELD TILE REPAIR OR ENGINEER APPROVED EQUAL 2'MIN. WATER MAIN EARTH LOAM BACKFILL PVC PIPE SAME SIZE AS CUT FIELD TILE ---------□---- TL EXISTING 2' MIN. FIELD TILE #53 STONE BACKFILL UNDER PVC PIPE FIELD TILE REPAIR DETAIL (") INCREASE TRENCH DEPTH AS NECESSARY TO PREVENT EXCEEDING RECOMMENDED PIPE JOINT DEFLECTION. USE FITTINGS AND CONCRETE ANCHOR BLOCKS IF TRENCH DEPTH EXCEEDS REASONABLE CONSTRUCTION DEPTHS. GRADE n MIN. 4'-0" CRUSHED STONE NOTE: 3'-0" 2'-0" AS DETAILED ON PLANS 2'-0" 3'-0" L+ ---= L...&.-§llii:ii�2il,li'il=�2ilil!il�1§:liill!lli,,___ 1 J,-.L.:::::: LJ1 O�r - 3 1 USE 6" OF No. 53 AGG. 2" CROWN ROLLED EACH 2" SUBGRADE FINISHED CROSS SECTION ACCESS ROAD NOTE: HORIZONTAL DISTANCES ARE MEASURED AT RIGHT ANGLES TO THE C.L. OF TRACKS BEYOND RfW LINE . I I • BEYOND RfW LINE I f-R.R. I t RfW 11 2' BEYOND TOE OF SLOPE (25' MIN.) 3' BEYOND DITCH LINE (25' MIN.) TYPICAL GATE VALVE CARRIER PIPE TO BE 0.1. RESTRAINED JOINT R.R.- 1 I R f W I I SEAL STEEL CASING PIPE PER SPECIFICATIONS RAILROAD CROSSING SECTION OPEN CUT OPEN CUT TYPICAL GATE VALVE MAIN HIGH STRENGTH POLYPROPYLENE FRAME AND COVER SET FLUSH WITH GROUND SURFACE 1. SEE PLAN SHEETS AND CROSS SECTIONS FOR SIZE AND TYPE OF PIPE 2. PLASTIC PIPE SHALL BE ENCASED WITH SAND. MIN 12'-0"STATE HIGHWAY i PAVEMENT MIN. 12'-0"STATE HIGHWAY • ANCHOR LUGS - ---+ -- -'-; ? I 20" FOR 518" & 3/4"METERS COMPACTED CLAY OR LOAM FILL AROUND PIT 24" FOR " METERS HOPE PIT WITH REINFORCED IBS WITH NOTCHES FOR SERVICE INE AS MANUFACTURED BY FRANCESVILLE DRAIN flLE (FRATCO) CORP. g ANGLE DUAL CHECK VALVE METER YOKE WILL -� EXTEND THRU WALL WITH¾"COPPER DUAL PURPOSE OUTLET CONNECTION METER COPPER SETTER WITH PRESSURE REDUCING VALVE. SEE SPECIFICATIONS FOR TYPE AND ACCESSORIES MANHOLE COVER SHALL BE ALUMINUM WITH -� LIFTING HANDLE AND PADLOCK HASP AS MANUF. BY HALLIDAY PRODUCTS MODEL No. A48R OR ENGINEER APPROVED EQUAL. 4"DIA. PRECAST CONG. MANHOLE CLA-VAL MODEL 990 ---K· 2" PRESSURE REDUCING VALVE ADJUST RANGE 28 TO 85 PSI MIN. PIPE COVER PER SPECIFICATIONS 2" HOPE SDR-9 CTS AS APPLICABLE OUTLET PIPE SLEEVE WITH LINK-SEAL (TYP. ALL PENETRATIONS) REDUCER--' AS REQUIRED CONG. FLOOR . , . _. · ... 4 ' -0" BRACING EYE ANGLE BALL VALVE 1" HOPE SER-9 CTS - - ~ FOR 1" &¾"INLET SETTERS UNLESS OTHERWISE SPECIFIED ¾" x 1" INCREASER CORP. STOP MODEL 470BT WITH INSERT STIFFENER MODEL 6133T BY A.Y. McDONALD MFG. CO. MAIN-------< □ NOTE: SADDLES REQUIRED ON ALL MAINS PER SPECIFICATIONS SETTER SUPPORT 16" LONG SCH. 80 RIGID PVC PIPE, BRACEY,"DIA METER & BOX SETTING . 5" . •;· . • : INLET ALL JOINTS SHALL BE WATER PROOF WITH BITUMINOUS MASTIC FORD SERIES 70 COPPER SETTER FOR 2" FLANGED METER WITH BYPASS, BALL VALVE INLET AND OUTLET, #VBB77-15B-44-77-G (GRIP JOINT FOR COPPER) AND #CF31-77 (2 REQ'D) FEMALE BRONZE METER FLANGE. CONTRACTOR SHALL VERIFY THE P.R.V. LAYING LENGTH TO FIT. BY-PASS FULL PORT BALL VALVE WITH PADLOCK WINGS 2" HOPE SDR-9 CTS AS APPLICABLE REDUCER AS REQUIRED 2" DRAIN WHEN APPLICABLE ALL JOINTS SHALL BE WATER PROOF WITH BITUMINOUS MASTIC VALVE BOX� COVER � � SLOPE ALUMINUM __ .../ VALVE BOX TOP 6"PVC -----1 SDR-35 PIPE PIPE SLEEVE WITH LINK SEAL ON ALL PENETRATIONS GATE VALVE � STONE LINE SIZE D.I. PIPE 3. IF ROCK IS ENCOUNTERED, MIN. 6" SAND BEDDING IS REQUIRED UNDER ALL TYPES OF PIPE. MIN. 2'-0" COUNTY ROAD MIN 2'-0" COUNTY ROAD No. 12 COPPER TRACER WIRE FLEXIBLE UTILITY MARKER WITH TWO TERMINAL TEST ACCESS POINT FOR TRACER WIRE, COLOR BLUE MODEL "TUFFCAT" CTFC07208U WITH DECALS CW-112 AND TOF-2580 AS MANUFACTURED BY CARSONITE INTERNATIONAL, PH. 1-800-648-7917 OR ENGINEER APPROVED EQUAL TO BE INSTALLED AT 1000 FT. MAXIMUM SPACING, IN FENCE LIES, ADJACENT TO FLUSH I FIRE HYDRANTS, ETC TRACER WIRE SHALL BE No. 12 AWG USE-2, RHW-2 ----,._ OR RHH SOLID COPPER WITH 45 MIL POLYETHYLENE INSULATION AND SUITABLE FOR DIRECT BURIAL INSTALLED LONGITUDINALLY ALONG THE PIPE TRENCH. ALL UNDER GROUND SPLICES IN TRACER WIRE SHALL BE CONNECTED WITH THE USE OF COPPERHEAD SNAKEBITE WATERPROOF CONNECTORS. GRADE ANCHOR N BARB ATTACHEMENT LOCATION MARKER WITH TRACER WIRE TERMINAL TEST POINTS MANHOLE COVER SHALL BE ALUMINUM WITH LIFTING HANDLE AND PADLOCK HASP AS MANUF. BY HALLIDAY PRODUCTS MOOEL No. A48R OR ENGINEER APPROVED EQUAL .• 4'-0" . 5" • .. l- -------'---'------- - -1:..:----1--- 4" DIA. PRECAST CONG MANHOLE ______________ VALVE BOX COVER 'ErsLOPE - -------------ALUMINUM VALVE BOX TOP . • • - .. ·. ' {/) .. . .. ,• SEE SPECIFICATIONS FOR METER TYPE AND ACCESSORIES FLANGED COUPLING ADAPTER PIPE SIZE TO METER SIZE ADAPTER CONG. FLOOR . ' :: ... : .. fu 1-- - 6" PVC s: SDR-35 PIPE c,: w '-' w CL CL z " � GATE VALVE 1'-6" MIN. 2" DRAIN WHEN APPLICABLE CREEK CROSSING SECTION SECTION PLAN #4 BARS CONTINUOUS TOP & BOTTOM HEADWALL DETAIL GRADE \ ,� " ;.. v ' HALL BE RESTRAINED _J MAIN S JOINT P CASING 3' BEYO IPE WITHIN THE AND SHALL EXTEND ND EACH END I - " ., v - ----------- - ------ L STEEL CASING PIPE PER SPECIFICATIONS TO BE BORED ROADWAY BORING SECTION STEEL CASING WITH BRICK I MORTAR END SEAL PER SPECIFICATIONS TWO SPACERS PLACED AT EACH OF OF CASING (TYPICAL) 6' - 1O' TYPICAL BETWEEN SPACERS POLYETHYLENE ENCASEMENT REQ'D FOR ALL D.I. PIPE 2' FROM BELL END CASING PIPE TRACER WIRE NYLON CABLE TIES FOR TRACER WIRE, MIN. 2 PER PIPE STAINLESS STEEL CASING SPACER WITH POLYMER RUNNERS AS MANUFACTURED BY CASCADE WATER WORK OR ENGINEER APPROVED EQUAL CARRIER PIPE TYPICAL CASING SPACERS AND END SEALS DETAIL 2" P.R.V. VALVE & SETTING 1 1/2" AND LARGER WATER METER & BOX SETTING ' REVISIONS BID SET C 2024 Mi,;twestem Engineers. Inc. 802 We.,l Broadway Streel P.O. Bo� 295 Loogoolee. lndi�na 47553 DATE Agril 2024 DESIGN R.D.W. DRAWN K.J.G. Q.C. CHECK PROJECT NUMBER 2020025-02 6 6 OF 6 I FILE NUMBER I 44170 Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2