Midwestern Engineers, Inc. Plan Preview

JUNCTION BOX STAINLESS STEEL CONTINUOUS PIANO HINGE FRONT VIEW RIGHT SIDE VIEW ' LEFT SIDE VIEW 7%" FACE-MOUNT PADLOCKABLE HASP LOUVER PLATES STAINLESS STEEL ALUMINUM MESH NOTE, JUNCTION BOX DIMENSIONS SHOWN ARE FOR REFERENCE ONLY, CONTRACTOR TO SIZE FOR APPLICABLE PUMP APPLICATION. JUNCTION BOX A DETAIL NOT TO SCALE PUMPS #1 & #2 JUNCTION BOX STAINLESS STEEL CABLE ACCESS ALUMINUM 16 GtiNflNUOUS PIANO l11NGr FRONT VIEW 'f :J 'f RIGHT SIDE LEFT SIDE VIEW VIEW 7%" -rAe�-MOUNi �ADcOGKABLE NAS� LOUVER PLATES STAINLESS STEEL ALUMINUM MESH NOTE, JUNCTION BOX DIMENSIONS SHOWN ARE FOR REFlcRENCE ONLY, CONTRACTOR Ttl SIZE FOR APPllCABLf: PUMP APPLIOATION. JUNCTION BOX B DETAIL NOT TO SCALE PUMP #3 & INSTRUMENTS SCADA SYSTEM NOTES 1. CONTRACTOR SHALL UTILIZE TOWN OF WATERLOO'S EXISTING SCADA SYSTEM INTEGRATOR BY CONTACTING NATHEN BURKHART WITH TORIC ENGINEERING AT 317-718-1800 FOR PRICING PRIOR TO BID. THE PROPOSED LIFT STATION CONTROL PANEL SHALL INCLUDE, BUT NOT LIMITED TO. THE FOLLOWING, A. FREE STANDING, 3 DOOR, TYPE 4X S.S. ENCLOSURE B. STAINLESS STEEL AIR CONDITIONER, TYPE 4X RATED C. MAIN NON-FUSED DISCONNECT D. POWER DISTRIBUTION BLOCK E. TVSS F. PHASE MONITOR G. MOTOR DISCONNECTS, SIZED FOR PUMPS H. MOTOR FUSES, SIZED FOR PUMPS I. VARIABLE FREQUENCY DRIVES, SIZED FOR PUMPS J. CONTROL POWER TRANSFORMER, 5KVA K. ALLEN BRADLEY COMPACTLOGIX PLC (OR EQUAL) L. MAPLE SYSTEMS 1O" TOUCHSCREEN (OR EQUAL) M. VEGA WL61 RADAR LEVEL TRANSMITIER (OR EQUAL) FOR PRIMARY CONTROL N. FLOAT SYSTEM FOR BACKUP CONTROL 0. INTRINSICALLY SAFE BARRIERS P. PANEL HEATER Q. ELAPSED TIME METERS FOR EACH PUMP R. H-0-A SWITCHES AND STATUS LIGHTS FOR EACH PUMP S. ALARM HORN AND BEACON T. MISSION CELLULAR BASED ALARM DIALER U. MISC. DEVICES REQUIRED TO MAKE A COMPLETE WORKING SYSTEM 2. SEQUENCE OF OPERATION TO BE COORDINATED DURING CONSTRUCTION w/ OWNER AND ENGINEER. 3. DIGITAL INPUTS, SITE POWER FAIL RTU POWER FAIL ATS POSITION (NORMAL/BACKUP) ATS NORMAL SOURCE AVAILABLE GENERATOR RUN STATUS (ON/OFF) GENERATOR RUN STATUS (ALARM) PUMP #1 RUN STATUS (ON/OFF) PUMP #1 RUN STATUS (ALARM) PUMP #1 SEAL LEAK PUMP #1 OVERTEMP PUMP #2 RUN STATUS (ON/OFF) PUMP #2 RUN STATUS (ALARM) PUMP #2 SEAL LEAK PUMP #2 OVERTEMP PUMP #3 RUN STATUS (ON/OFF) PUMP #3 RUN STATUS (ALARM) PUMP #3 SEAL LEAK PUMP #3 OVERTEMP STATION HIGH LEVEL DIGITAL OUTPUTS, PUMP #1 CALL PUMP #2 CALL PUMP #3 CALL ANALOG INPUTS, WETWELL LEVEL 4. SEPARATE ALL POWER AND CONTROL: DIGITAL ANO ANALOG, INTO DEDICATED CONDUITS. MINIMUM COVER ON THE SITE SHALL BE 24" WITH WARNING TAPE AT 12" COVER UNLESS OTHERWISE REQUIRED BY NEC. •,._�Ps R e) O ,::: P ,s O�S §' ED�S�EsRVg lCe_s E DROP BY NIPSCO . -=obD � V : PROPOSED CONDUIT AND WIRE DOWN POLE BY NIPSCO 1'-0" T CONG SLAB w/ No. 6 - BARS @ 12" O.C.E.W. PLACED 2" BELOW TOP OF SLAB, OVER MIN. 6" COMPACTED SUB-BASE 30"x30" #5 BARS@ 12" o.c. j 4 'l�. ,::: : 1 l:'l"i _ ' [ 'fl: II 1 1 1 :3 1 :r,_ ; ,;;; . � ..;;;;. ;;::_ ;::::::;;_ ;:::::;:::::::;::::_�·;::::;::::'::::;.;:::::;:::;::• ;� 3 :;J ,, \:::: MIN �_-;:::::;:;. ;:; .�.:;: . :::;_ �.�. rG'� JJ:lii; � l '"]j, � ;';- 1 I I �. •>- ' - [�I' 11 • • . , I J 1 2" 1 -______W ___ l c_ DT_ H _ O _ F _ G_ E_ N _ E R _ A_ T_ O _ R _______ 12" _ No. 6 CONT., TYP. SECTION GENERATOR PAD DETAIL NOT TO SCALE -PROPOSED CT CABINET AND CONTRACTOR TO PROVIDE AND INSTALL NEW LED DUSK-TO-DAWN LIGHT w/ WEATHERPROOF SWITCH ON 1),'' ALUMINUM RISER, HUBBELL CAT.# DDL-9LU, 39W LED OR EQUAL LENGTH OF STAND x 4' DEEP • • 24" . .. .._ . ••• • . . •• . ,. • .. . . . � .. • .. ., • • .. �1 . • . " • • .. .. . . . L , • .. � •.. 1 . • " T· 12" • ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) )(," STAINLESS STEEL ALL-THREADS IN CONCRETE --4"x4b>-1'4" -,-;;:::::=.r,--:J" ALUM. ANGLE • J , " ALUM. BASE PLATE BASE DETAIL NOT TO SCALE - ALUMINUM ---1"'�'1::: / METER BASE BY CONTRACTOR, METERING BY NIPSCO CONTROL WIRE IN CONDUIT , TO ATS PER 1/0 LIST r;:::: === = = ::::;; = � urr � ST ::::, t � Tl � ON :;::=;;;= ===== �h] UNI-STRUT 4" ALUMINUM-�-1 ANGLE SEE BASE DETAIL � THIS SHEET ". 36" COVER 0 . ... . . CT CABINET - . . . - AUTOII.I.TIC TRANSFER SlflTCH 400A-3P NEIi.i. 4X S.S. ... ' • • . " C ' " . • I • • • -• • PUIIP C O NTR O L PANKL NEIi.i. 4X S.S. • . ;, .. . ... • . . . - . • /CONTROL WIRE IN CONDUIT � TO GENSET PER 1/0 LIST / rCONTINUOUS HINGED NEMA 4X S.S. VENTED JUNCTION BOX SEE DETAIL THIS SHT. � F.;; un "' cn�o al ,uncnOI DOI A DOI B MIN. 60" SEPARATION ' . • • • . .• . ,... . . ..; .. .• . ,.... . . . . . . w/ WARNING ,- . ,.. • • ,.i • � TAPE @ 12" ' � • '' • •• .A- • •, • � . .. . . ,. . ·r· . . .. - .. J "" ,.. • ';;;:;::��« 1 .1\".==��:::::·';;:�·=· ;;: ·=· ;::;::·=�� .. .. �.. . ,'!a • -· • "==· =· ='==· �c:·=- =� =· =c0==:J.). • . .. - . • . . . - . . . .. • ' - - . ' . - • i-- ;,. lJ .a � � ,. • L-- I '". -II--��· ....,...����""',1,--tt'�"" �--tt--------".�::; ";"""'................. �--r--'.:, LRADAR c.VEL • • ... -- -- -- - .,.i'- - - lo- • ..i,. I I , • • • • • ·"\ ,. � • • : • : ,'=· =· =- "='' "=· =· ""'==;=;' ""+==1== •.• � . '.A I:' ' - ­ . . ... . . ,. 38" LONG SWEi:'P-· i:'LMWS (1Y�.) (4) #600 MCM THWN� 4" CONDUIT NOTE: SEE ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION • • ,., •. ,.1 • ' ... • EXOTHERMICALLY WELD #1/0 CU. - IN }\"o SCH. 80 PVC CONDUIT TO }\"x10' CU. CLAD GND. ROD (TYP. OF 3 ON 10' TRIANGULAR SPACING) • ,, ... . .. . . .-i � .,J · • ,.i_ .... • • .. • • A • • • • • - " - _ _.. • A • A , LPQWER AND CONTROL TO GENERATOR LCONTROL, BLOCK HEATER AND BATIERY CHARGER TO GENERATOR GENERAL ELECTRICAL NOTES ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL. ALL CONDUIT SHALL BE SCHEDULE 80 PVC IF BURIED, ALUMINUM IF EXPOSED UNLESS OTHERWISE NOTED. GROUT AROUND ALL PENETRATIONS INTO CONCRETE STRUCTURES. CONDUITS SHOWN ON PLANS IS FOR INFORMATIONAL PURPOSES ONLY AND IS NOT NECESSARILY MEANT TO INDICATE EXACT QUANTITY OR LOCATION. , ALL ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL UNLESS OTHERWISE NOTED. ALL ENCLOSURES SHALL HAVE A HASP AND STAPLE FOR PADLOCK. • • • ' •• • ,I • ' • DIGITAL AND ANALOG CONTROL, - PUMP #1, #2 AND #3 POWER ' • "' • • . ·.- .. • ·"' • • , CONTROLLER • • •• • • • • • ' • • ' ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, OTHER MATERIAL. AND INSTALLATION FOR A COMPLETE AND FUNCTIONAL SYSTEM. HIGH WATER ALARM ELEV. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. SEED AND STRAW OR STONE ALL SURFACES TO PRE-DISTURBED CONDITION. CONTRACTOR TO REMOVE UNUSED ELECTRICAL EQUIPMENT AS A RESULT OF THE PROJECT. OWNER RESERVES THE RIGHT TO ANY REMOVED EQUIPMENT. ANY UNWANTED EQUIPMENT, MATERIAL, CONDUCTORS, ETC. SHALL BE DISPOSED OF BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. ENSURE 5' MIN. BETWEEN WETWELL VENT AND JUNCTION BOX. LOCATE NEW JUNCTION BOX AT A MIN. OF 18" ABOVE TOP OF WELL. FIELD VERIFY EXACT LOCATIONS w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION. CONTRACTOR TO VERIFY CONDUIT SIZE BETWEEN JUNCTION BOX AND PUMPS IN WET WELL TO ACCEPT PUMP POWER CABLES (PER NEC), TYPICALLY USE LONG SWEEP ELBOWS. ALL UTILITY FEES WILL BE PAID BY OWNER IN FULL PRIOR TO CONSTRUCTION. CONTRACTOR TO CONTACT CHRISTIAN RAMIREZ w/ NORTHERN INDIANA PUBLIC SERVICE CO. AT 260-316-3606 A MIN. OF FOUR WEEKS PRIOR TO COORDINATE NEW SERVICE INSTALLATION. NOTIFY OWNER OF ALL REQUIRED OUTAGES A MIN. OF 48 HOURS IN ADVANCE. POWER FOR TEMPORARY BYPASS PUMPING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. • • • • • • • • • • •• • PROPOSED U.S. 6 LIFT STATION RISER NOT TO SCALE • • . ' II • • • ( � • .. .. . � A• (3) 34HP 480V-3o 40 FLA • , • • • .P ' . ' • • • • • • • ELEV. LAG PUMP ON ELEV. LEAD PUMP ON ELEV. PUMP OFF REVISIONS BID SET C2024 Midwc.,;1cm Engineers. Inc. 802 West Broadway Sir<'<'! P.O. Bo,; 295 Loogootee. lnrlinna 47553 DATE MARCH 2024 DESIGN A.F.B DRAWN C.N.M. Q.C. CHECK S.M.S. PROJECT NUMBER 2020073-00 28 28_0F 35 I FILE NUMBER I Ll:l 100 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2