GENERAL ELECTRICAL NOTES ALL WORK SHALL COMPLY WITH INDIANA ELECTRICAL CODE, CURRENT EDITION. PROVIDE ALUMINUM UNI-STRUT AND ACCESSORIES AS REQUIRED TO MOUNT ELECTRICAL EQUIPMENT. ALL HARDWARE SHALL BE STAINLESS STEEL ALL CONDUIT SHALL BE SCHEDULE 8D PVC IF BURIED, ALUMINUM IF EXPOSED UNLESS OTHERWISE NOTED. GROUT AROUND ALL PENETRATIONS INTO CONCRETE STRUCTURES. CONDUITS SHOWN ON PLANS IS FOR INFORMATIONAL PURPOSES ONLY AND IS NOT NECESSARILY MEANT TO INDICATE EXACT QUANTITY OR LOCATION. ALL ENCLOSURES SHALL BE NEMA 4X STAINLESS STEEL UNLESS OTHERWISE NOTED. ALL ENCLOSURES SHALL HAVE A HASP AND STAPLE FDR PADLOCK. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT, WIRING, OTHER MATERIAL, AND INSTALLATION FDR A COMPLETE AND FUNCTIONAL SYSTEM. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. SEED AND STRAW OR STONE ALL SURFACES TO PRE-DISTURBED CONDITION. CONTRACTOR TO REMOVE UNUSED ELECTRICAL EQUIPMENT AS A RESULT OF THE PROJECT. OWNER RESERVES THE RIGHT TO ANY REMOVED EQUIPMENT. ANY UNWANTED EQUIPMENT, MATERIAL, CONDUCTORS, ETC. SHALL BE DISPOSED OF BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. ENSURE 5' MIN. BETWEEN WETWELL VENT AND JUNCTION BOX. LOCATE NEW JUNCTION BOX AT A MIN. OF 18" ABOVE TOP OF WELL. FIELD VERIFY EXACT LOCATIONS w/ OWNER DURING CONSTRUCTION PRIOR TO INSTALLATION. CONTRACTOR TO VERIFY CONDUIT SIZE BETWEEN JUNCTION BOX AND PUMPS IN WET WELL TO ACCEPT PUMP POWER CABLES (PER NEC), TYPICALLY USE LONG SWEEP ELBOWS. ALL UTILITY FEES WILL BE PAID BY OWNER IN FULL PRIOR TO CONSTRUCTION. CONTRACTOR TO CONTACT CHRISTIAN RAMIREZ w/ NORTHERN INDIANA PUBLIC SERVICE CO. AT 260-316-3606 A MIN. OF FOUR WEEKS PRIOR TO COORDINATE NEW SERVICE INSTALLATION. NOTIFY OWNER OF ALL REQUIRED OUTAGES A MIN. OF 48 HOURS IN ADVANCE. POWER FOR TEMPORARY BYPASS PUMPING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. SCADA SYSTEM NOTES 1. CONTRACTOR SHALL UTILIZE TOWN OF WATERLOO'S EXISTING SCADA SYSTEM INTEGRATOR BY CONTACTING NATHEN BURKHART WITH TORIC ENGINEERING AT 317-718-lBDD FOR PRICING PRIOR TO BID. THE PROPOSED LIFT STATION CONTROL PANEL SHALL INCLUDE, BUT NOT LIMITED TO, THE FOLLOWING: A. FREE STANDING, TYPE 4X S.S. ENCLOSURE B. MAIN NON-FUSED DISCONNECT C. POWER DISTRIBUTION BLOCK D. TVSS E. PHASE MONITOR F. MOTOR CIRCUIT BREAKERS, SIZED FOR PUMPS G. CONTROL POWER TRANSFORMER, 5KVA H. CONCERTOR COMMUNICATIONS GATEWAY AND TOUCHSCREEN (OR EQUAL) I. APP PRIMARY LEVEL CONTROLLER J. TIME DELAY RELAY FOR LAG PUMP STARTER K. INTRINSICALLY SAFE BARRIERS L. PANEL HEATER M. ELAPSED TIME METERS FOR EACH PUMP N. SELECTOR SWITCH FOR RADAR/OFF/FLOATS CONTROL 0. H-0-A SWITCHES AND STATUS LIGHTS FOR EACH PUMP P. MISSION MYDROB50 CELLULAR ALARM DIALER Q, MISC. DEVIC.S REQUIRED TO MAKf: A COMPLETE WORKING SYSTEM 2. �.tlUENCi:; iic OPERATION TO st COORDINAfi::O DURING CONSTRUCflDN w/ OWNER AND ENGINEER, ,l, D1()1fA� INPUfs· SITE POWKR FAIL RTU POWER FAIL ATS POSITION (NORMAL/BACKUP) ATS NORMAL SOURCE AVAILABLE GENERATOR RUN STATUS (ON/OFF) GENERATOR RUN STATUS (ALARM) PUMP #1 RUN STATUS (ON/OFF) PUMP #1 RUN STATUS (ALARM) PUMP #1 SEAL LEAK PUMP #1 OVERTEMP PUMP #2 RUN STATUS (ON/OFF) PUMP #2 RUN STATUS (ALARM) PUMP #2 SEAL LEAK PUMP #2 OVERTEMP STATION HIGH LEVEL DIGITAL OUTPUTS: PUMP #1 CALL PUMP #2 CALL ANALOG INPUTS: WETWELL LEVEL 4. SEPARATE ALL POWER AND CONTROL; DIGITAL AND ANALOG, INTO DEDICATED CONDUITS. MINIMUM COVER ON THE SITE SHALL BE 24" WITH WARNING TAPE AT 12" COVER UNLESS OTHERWISE REQUIRED BY NEC. 1' O" T CONC SLAB / N 6 - w 0. - BARS @ 12" O.C.E.W. PLACED 2" BELOW TOP OF SLAB, OVER MIN. 6" COMPACTED SUB-BASE · -· ·11r ili 11 • . • , • • • ' .111= • 11 •• ' 30" 30" #5 BARS X ' - . . l @ 12" o.c. 4 3" MIN. • . . . . . . 4 :;�1111. I 1 !f%JJ 1 No. 6 LENGTH OF STAND x 4' DEEP • • 2 4 " . . . • ... . ... ,�. • •• . . . . .� . • 4 . . .. . ALUMINUM ANGLE WELDED TO ALUMINUM BASE PLATE (4) !," STAINLESS STEEL ALL-THREADS IN CONCRETE • 4"x4 H �" ALUM. ANGLE 12" 12" WIDTH OF GENERATOR CONT., TYP. - - ,��. !," ALUM. 12" • � SECTION GENERATOR PAD DETAIL NOT TO SCALE • . . •• •. ·, . ' • •• , . � . ·�· • BASE DETAIL NOT TO SCALE BASE PLATE • 277/480V-30, 4WSERVICE DROP BY NIPSCO l / (ONDUIT ANO WIRE .'.,� DOWN POLE BY NIPSCO -, � f//'Q_rr']ir c; t'.:· �� ---CONTRACTOR TO PROVIDE AND INSTALL '\\ NEW LED DUSK-TO-DAWN LIGHT w/ WEATHERPROOF SWITCH ON 1Ji,'' ALUMINUM RISER, HUBBELL CAT.# DDL-9LU, 39W LED OR EQUAL PROPOSED POLE--�r BY NIPSCO (4) #3/0 THWN----i 2!," CONDUIT 36" LONG SWEEP ELBOW (TYP.) V : PROPOSED CONDUIT AND WIRE DOWN POLE BY NIPSCO ALUMINUM UNI-STRUT 4" ALUMINUM-�-, ANGLE SEE BASE DETAIL � THIS SHEET " . 0 .. -PROPOSED CT CABINET AND METER BASE BY / CONTRACTOR, METERING BY NIPSCO CT CABINET f-- - .. • • • • . . AUTOIIATIC TIW!SJ'KR S1llTCII 200!.-3P NEIU. il S.S. . • • • 3 6 " COVER • .. • " .. w/ WARNING • 12" • TAPE @ 11 • I I .. . . • •• •• .. . • " .. ··- . - .. • " • . •• • • . " • . - •�A• . • . . • • " . . • • • . • • . • . • . • . ... . - . - • • • • . - • ' • • . . ,, . e· • . . " . . • .. � . • NOTE: SE� ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION EXOTHcRMICALbY WELD #4 CU, INJi"¢ SCH. 8d PVC CONDUIT fo -),'\10' CU. CLAD GND. ROD (TYP. OF 3 ON 1O' TRIANGULAR SPACING) -Powrn ANO CONTROL Tb GENERATOR JUNCTION BOX STAINLESS STEEL CABLE ACCESS ALUMINUM FRONT VIEW 1---14%"- '.,:' ' ' RIGHT SIDE LEFT SIDE VIEW VIEW I '-<:ll\"•- I �311·, ..----LOUVER PLATES STAINLESS STEEL --ALUMINUM MESH • Im STATION PUIIP CONTROL PANEL - ./ :ONTROL WIRE IN CONDUIT ill O ATS PER 1/0 LIST -:CONTROL WIRE IN CONDUIT ill/ TO GENSET PER 1/0 LIST NEIU. il S.S. :: : 1 1 ' ii \1111 I I I I I a' ' .._ • � � .... � � �CONTROL, BbOCK HEATER AND BATTERY CHARGER TO GENERATOR • DIGITAL AND ANALOG CONTROL,PUMP #1 AND #2 POWER •unCTIO _ BOX - ·, . • • • • - A • • . • • ' / CONTINUOUS HINGED NEMA 4X S.S. VENTED JUNCTION BOX SEE DETAIL THIS SHT. . . • MIN. 60" SEPARATION · . -,- '' ,. • _, ' . - 11iii; I - . ' . • • - 1 I . ., . . .. • ,, ·r � h = • = • = = CD= • ,, . ' A • • • • = · � . ,-,-.J • • • j• o:r .... • ;,; . =�I ---�� "' �-��-'-"' l/1\LlLJ[_ __:=--'---- \ • • ' RADAR LEVEL SENSOR " ' HIGH WATER ALARM 1 " CONTINUOUS PIANO HINGE FACE-MOUNT PADLOCKABLE HASP NOTE: JUNCTION BOX DIMENSIONS SHOWN ARE FOR REFERENCE ONLY, CONTRACTOR TO SIZE FOR APPLICABLE PUMP APPLICATION. JUNCTION BOX DETAIL NOT TO SCALE • •• • • • • " ' " - ' A • " • • • (2) 10HP 480V-3o 14 FLA PROPOSED WAYNE STREET LIFT STATION RISER NOT TO SCALE LAG PUMP ON ' • • LEAD PUMP ON -. A • PUMP OFF ... • • • A • • • REV1SIONS BID SET 02024 Midwe�!em Engineers. Inc. 802 West Bro�dway Street P.O. Bo.\ 295 Loogootee, Indi,1nu 47553 OAIT MARCH 2024 DESIGN A.F.B DRAWN C.N.M. Q.C. CHECK S.M.S. PROJECT NUMBER 2020073-00 30 30 OF 35 I Fllf NUMBER I � L IO� f? Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2