Midwestern Engineers, Inc. Plan Preview
[NSTALL VALVE W/ PLUG & CONC. THRUST BLOCK FOR HYDRANT AT END OF LINE CONC. THRUST BLOCK MAIN .. ' NOTE, VALVE BOXES SHALL BE SCREW TYPE 2-PIECE OR 3-PIECE CAST IRON WITH CAST-IRON LID IN ALL STONE.ASPHALT OR CONCRETE SURFACE AREAS. ANCHORING COUPLING FLUSH HYDRANT WITH MECHANICAL JOINT CONN. APPROX T-0" OR AS DIRECTED BY ENGH'1EER VALVE BOX '\_ COVER B ALUMINUM VALVE- 1 ----- I MIN. 2'-0" D.I. MECHANICAL JOlNT TEE NOTE USE REDUCING TEE IF REQUIRED BOX TOP MAlN 6" SDR 35 PVC PIPE I GATE VALVE D.I. TEE ANCHORING COUPLING DETAIL OF FLUSH HYDRANT CONNECTION #4 EPOXY COATED REBAR BENT AS SHOWN D.I. FITTING WITH MECHANJCAL n n FLUSH HYDRANT (SEE SPECS) PRECAST CONC. SLABS OR STONE WEDGED +ffH -- BETWEEN HYDRANT AND FlRM FACE OF TRENCH l6 CUBIC FEET OF WASHED GRAVEL OR WASHED STONE #5 NOTE: WATER METER & PRESSURE REDUCING VALVE COMBINATION AS SHOWN SHALL BE INSTALLED ON ALL SERVICES 3/4" OR I" PRESSURE REDUCING VALVE MODEL BR4 WITH A REDUCED OUTLET PRESSURE RANGE OF 15 TO l 50 P.S.L AS MANUFACTURED BY WILKINS (A ZUR.t\1 COMPANY) ANGLE DUAL CHECK-- - - - YALVE YOKE \VITI-I BRACING EYE _______, SEE SPEClFICATJON METER YOKE TO EXTEND THRU WALL WITH¾' ' ' --� COPPER DUAL PURPOSE OUTLET CONNECTION / / / \ \ \ I-IIGl-l STRENGTH POLYPROPYLENE METER BOX FRAME & COVER BRASS NIPPLES ,.,...,,---20" 1.D 1-1.D P.E. METER PIT 30" DEEP / SEE SPECIFICATIONS ANGLE BALL VALVE METER COPPERSE1TER SEE SPECIFICATIONS METER SEE SEPECTFICATIONS 3/4" OR l" H.D.P.E. SDR-9 C.T.S SERVICE FROM MAIN 16" LONG SCH. 80 RIGID PVC. PIPE BRACE. 1/2" DlA. STANDARD 20" I D i V IETER PIT 30" DEEP PRESSURE GAUGE STANDARD COPPER METER IDLER WITH 0-200 P.S.! TAPPED PRESSURE GAUGE. GAUGE SHALL BE OF MATERIAL SUITABLE FOR GROUND WATER CONDITIONS. TO DETERMJNE EXACT FLOW LOSSES. 5/8" x 3/4" WATER METER SHALL BE INSERTED IN PLACE OFIDLER FORD CAT No. VY-92-12 W!TH FULL PORT WING BALL STOPS ON BOTH ENDS AND BRACING EYE. (OR EQUAL) GATE VALVE- - � STANDARD METER BOX COVER SET FLUSH WITH GROUND SURFACE 'e'!' ALUMINUM VALVE BOX TOP & COVER ��- -- +S;;��,53 v 7�- / /,1/,0 �1//Y 6" SDR-35 PVC PIPE "' / GAIEVALVE -.______ REDUCER IF REQ'D -------- - GATE VALVE WATER MAIN -BELL RESTRAINT HARNESS MEGALUG BY EBAA IRON, INC. REQ'D FOR 2 JOINTS BEYOND FJTT[NG EACH WAY �-- -- - -- ----- -- �- .IO[NT RESTRAINED TO PIPE BY USE OF A MEGALUG BY EBAA IRON, [NC. DETAIL OF PRESSURE REDUCING VALVE & WATER METER 16" LONG RIGID P.V.C. PlPE BRACE 1/2" DIA D I TEE I · MIN. or 40 Lr. STONE BED A* STONE BED VERTICAL BELL RESTRAINT HARNESS ,,_____.,,______MEGALUG BY EBAA IRON. #4 EPOXY COATED REBAR BENT AS SHOWN ,,,., .,. SEE SPECJFICATIONsSTONE BED IIORJZONTAL INC.REQ' D FOR 2 JOINTS BEYOND FITTING EACH WAY FLEXIBLE UTILITY MARKER \VITI-I TWO TERMJNAL TEST ACCESS POINTS FOR TRACER WrRE. COLOR BLUE MODEL "TUFFCAT" CTFC07208U WITH DECALS CW-112 AND TOF-2580 AS MANUFACTURED BY CARSONTTE [NTERNATIONAL. PH 1-800-648-7917 (OR EQUAL) TO BE [NSTALLED AT 1000 Fl'. MAXIMUM SPAC[NG. IN FENCELJNES. ADJACENT TO FIRE/FLUSH HYDRANTS ETC. «�,ct, Y, .-<<« '>;l,,�;'��" '�-»--'»."% "-'--"<�-;:,. ANCHOR BARB . AITACl·TMENT �3 3 11" ,,, 11""'---� I" � \j GRADE I 11 TYPICAL THRUST BLOCK DETAIL TI�ACER WIRE SHALL BE No. 12 AWG USE-2, RHW-2 OR RHH 9 N EXISTING MAIN MUELLER #H-J04SS STAINLESS STEEL TAPPJNG TEE WlTH SS OUTLET FLANGE(OR EQUAL) EXISTING MAIN MUELLER FLxMJ GATE TAPPING VALVE (OR EQUAL) NEWMAlN SOLID COPPER WIRE WlTH 45 MIL POLYETJ-IYLENE INSULATION AND SUITABLE FOR DIRECT BUR. JAL INSTALLED LONGlTUDlNALLY ALONG Tl-IE PIPE TRENCH /\LL UNDER GROUND SPUCES [N TRACER WIRE SIIALL BE CONNECTED WITH A 3M ELECTRICAL PRODUCT DIYISJON No. 0.-i4007-09053 DlRECT BURlAL SPLICE KIT�- LOCATION MARKER WITH TRACER WIRE TERMINAL TEST POINTS NOTE VALVE BOXES SHALL BE SCREW TYPE. 2-P[ECE OR 3-PIECE CAST [RON WITH CAST n,ON LJD lN ALL STONE, ASPHALT OR CONCRETE AREAS. VALVE BOX COYER \ � �'(<, =' ",jfy;· DETAIL OF WET TAP TO EXISTING MAIN POLYE'!'l IYLENE ENCASE_ MENT REQUIRED FOR ALL D.I. PIPE ALUMTNlJM <('' If 71 �<;, <- '1/ VALVE BOX TOP " � Y/ SEAL CASING WITH BRICK/MORTAR TWO SPACERS PLACED AT EACII END OF CASING (TYPICAL) 6' - IO' TYP!CAL • BETWEEN SPACERS CASING PIPE 2' FROM BELL ENI 6" SDR 35 PVC PIPE PER SPEClflCATION � TRACER "-....H L F = ='t=''F ==== ===rz ========= =; == =,/==z=== == "j" === j'= WlRE � L �- NYLON CABLE TIES FOR TRACER WIRE, MIN. 2 PER Pl. PE CARRIER Pl. P E BUTTERFLY VALVE MUELLER' - -- -LlNESEAL XP (250 PSI) OR THE HENRY PRATr EQUIVALENT LEAK DETECTION DEVICE HOLLOW COPPER TUBE TERMJNAL TEST ACCESS POINT "INSERT TRACER WIRE INTO TUBE AND CRJMP NO. 12 COPPER TRACER WIRE NOTE: CONTRACTOR SHALL BE REQUIRED TO PROVIDE PHOTOGRAPHS OF TI-IE HELD TILE REPAIR (BOTH PR.IOR TO AND Ai 0 l'ER REPAIR) PRIOR TO EARTH LOAM BACKFILL TI-IE CONTRAC.J'OR SJ{ALL PROVIDE CLOW F-20 OR MUELLER #1· 1-840 CUT-IN SLEEVE (OR EQUAL) EXISTING MAIN MUELLER FLxMJ GATE VALVE (OR EQUAL) EXISTING MAIN A LABELED 3-RING BINDER CONTAIN[NG THE REQUIRED PHOTOGRAPHS EACH PHOTOGRAPH SHALL BE PROPERLY LABELED WITH THE PROPER STATIONING, SIZE OF 'ITLE REPAlR, DATE OF REPAIR AND PROPERTY OWNER. P.V.C. P[PE SAME SIZE AS CUT FlELD TILE EARTH LOAM BACKFILL CUT-IN SLEEVE FOR VALVE OR TEE TO EXISTING MAIN FERNCO ADAPTER (OR EQUAL) c:-----;,\--+�---- EXISTING _/ --"'-+ ...ill- - - - - - - - -.....t-7\r-- ] - - - - -+�� EXISTING FIELD TILE 2' MJN. 2· MIN. • I FIELD TILE #57, STONE BACKFrLL UNDER P.Y.C. PIPE WATER LINE FIELD TILE REPAIR DETAIL VALVE BOX COVER \ #6 REIN!' RODS (2 REQ'D.) CONC. PAD � SET FLUSH WlTH PAVEMENT OR GROUND SURFACE GATE VALVE IF REQ'D-� ANCHOR COUPLING OR - � FOSTER ADAPTER STONE MIN. OF 40 L.F , I 0 .. ·• -----D.L OR P V C. MA[N L[NE PlPE (TYP.) BELL RESTRAINT HARNESS 11-- ---MEGALUG BY EBAA [RON.INC. REQ'D FOR 2 JOINTS (MIN. 40') BEYOND FITTING / VALVE EACHWAY ,,--- - VALVE WITH MECHANICAL JOINT RESTRAINED TO PfPE BY USE OF MEGALUG BY EBAA IRON. INC. I, MIN. Of40L.f. GATE VALVE [F REQ'D FOSTER ADAPTER STAINLESS STEEL CASING SPACERS WITII POLY!\1ER RUNNERS AS MANUfACTURED BY CASCADE WATERWORKS MFG. PH: 1-800-426-4301 BUTTERFLY VALVE DETAIL GATE VALVE IF REQ'D ANCHOR COUPLING OR FOSTER ADAPTER D.J. TEE l ANCHOR COUPLING OR CONCRETE THRUST BLOCK TYPICAL CASING SPACERS AND END SEALS DETAIL DETAIL OF BRANCH CONNECTION FOR DUCTILE, CAST IRON OR PLASTIC PIPE TYPICAL WATER DETAILS REVlSIONS -12912:JZ "' BID SET 0 2023 Midwestern Engineer:;. Inc. 802 We,;L Bru:odw:iy Street P.O. Bo., 195 Loogoote,:. lndimm 47553 DAT£ JUNE 2023 DESIGN CWR DRAWN ORK Q.C. CHECK PROJECT NUMBER 2021012-04 2 1 21 DF I � L£ NUMBER _ 43218 27 I Do Not Use Plan Previews for Take Off
Made with FlippingBook
RkJQdWJsaXNoZXIy NjAyODM2