Midwestern Engineers, Inc. Plan Preview

z � , C z � 0 C w , , z m w � m 0 " z ,z <� NOMr aj I z Mo ! ii N oo �· WO �� Cl --- oo N Q ;\J �� � --- - .,- I QC ., 0 .. �8 • w < " zZ " Oc - Cl o< !al �u c_ la -N i c " m <• INDIANA DEPARTMENT OF TRANSPORTATION: Vincennes District 3650 U.S. HIGHWAY 41 VINCENNES, IN 47519 PHONE: 1-800-279-5758 EMAIL: SWINCOMMUNICATIONS@INDOT.IN.GOV DISTRICT PERMITS MANAGER RANDY CARIE PHONE: 1-812-895-7368 EMAIL· RCARIE@INDOT.IN.GOV DISTRICT PERMIT INSPECTOR DWAYNE DETZER PHONE: 812-937-4481 EMAIL: DWDETZER@INDOT.IN.GOV UTILITIES SANITARY/WATER Town of Santa Claus 90 N. Holiday Blvd P.O Box 92 Santa Claus, IN 47579 Phone: 812-937-2551 SPENCER COUNTY: County Commissioners James Seiler - District 1 Heather Gries - District 2 Thomas Brown - District 3 200 Main Street Rockport, IN 47635 Phone: (812) 649-6004 Highway Superintendent Dale Kenney 920 E. County Road 800 Chrisney, IN 47611 Phone: (812) 362-8331 Auditor Melissa Bunner 200 Main Street, Courthouse Rm 6 Rockport, IN 47635 Phone: (812) 649-6004 GAS. Community Natural Gas Co, 303 N. Washington St. P.O. Box 320 Dale, Indiana 47523 Phone: 812-937-2376 Email: dale@communitynaturalgas.com TELEPHONE Perry-Spencer Rural Telephone Cooperative 11877 E. State Road 62 P.O. Box126 Saint Meinrad, Indiana 47577 Phone: 812-357-2123 ELECTRIC Centerpoint Energy 211 NW Riverside Drive Evansville, Indiana 47708 Phone: 800-227-1376 Southern Indiana Power P.O. Box219 HOLEY MOLEY �YS. Tell City. IN 47586 Phone: 812-547-2316 "CALL BEFORE YOU DIG" (lWO WORKING DAYS PLEASE) 1-800-382-5544 INSIDE INDW<A PROPOSED WATER _ _jif) PROPOSED WATER MAIN & SIZE ® PROPOSED GATE VALVE @) PROPOSED BUTTERFLY VALVE � PROPOSED BLOW OFF VALVE ? PROPOSED FLUSH HYDRANT l PROPOSED 2 WAY HYDRANT PROPOSED 3 WAY HYDRANT • PROPOSED HYDRA STOP • PROPOSED INSERTA VALVE [� PROPOSED LEAK DETECTION ill PROPOSED/ RELOCATED METER 8 PROPOSED PRV 0 PROPOSED CHECK VALVE w PROPOSED CUT AND CAP 'T' 1-800-428-5200 FRO� OUTSIDE INDW<A EXISTING WATER 4" EXISTING WATER MAIN & SIZE -� 8 EXISTING GATE VALVE @ EXISTING BUTTERFLY VALVE • EXISTING BLOW OFF VALVE 8 • EXISTING FLUSH HYDRANT I' .. EXISTING 2 WAY HYDRANT EXISTING 3 WAY HYDRANT 8 • EXISTING HYDRA STOP @ EXISTING INSERTA VALVE r:7 EXISTING LEAK DETECTION @ EXISTING METER • EXISTING PRV 0 EXISTING CHECK VALVE '" EXISTING YARD HYDRANT (}) EXISTING CORP. STOP GENERAL TOPO @ SIGN o SATELLITE DISH El RIGHT OF WAY MARKER ,o MAIL BOX o POST/BOLLARD EJ SANITARY MANHOLE 8 STORM MANHOLE @TREE WOOD/ BARBED WIRE FENCE ELECTRIC/ CHAINLINK FENCE [i§_] HOUSE H.T. I HOUSE TRAILER �BURIED TELEPHONE CABLE -?- LIGHT POLE &--- POWER POLE/ GUY WIRE GAS MAIN -,--,-- TELEPHONE --,o-- FIBER OPTIC OVERHEAD ELECTRIC � SURVEY CONTROL POINT & SURVEY MONUMENT !ID ELECTRIC METER ii W GAS VALVE/ GAS METER GENERAL NOTES: 1. TOPOGRAPHY SHOWN ON PLAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. THE HORIZONTAL LOCATION DATA IS BASED UPON THE INDIANA STATE PLANE COORDINATE SYSTEM (WEST ZONE) REFERENCED TO THE 1983 NORTH AMERICA DATUM (NAD83) ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICANVERTICAL DATUM (NAVD 88) 3. THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 1-800-382-5544PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 4. THE LOCATION OF EXISTING UTILITIES, ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GENERAL LOCATION. ALTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA. 5. EXACT LOCATION OF GATE/BUTTERFLY VALVES, HYDRANTS, FITTINGS, ETC. TO BE DETERMINED AT THE TIME OF CONSTRUCTION. 6. DOWN TIME COORDINATION MUST BE MADE WITH THE WATER UTILITY PRIOR TO WET OR DRY TAPPING EXISTING WATER MAINS. COORDINATE WITH RUSSELL LUTHY, UTILITIES SUPERINTENDENT, AT 1-812-544-2354, A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO WET/DRY TAPPING OF EXISTING MAINS. 7. PROPERTY LINES, WHERE SHOWN, ARE BASED ON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE SHEETS DO NOT REPRESENT THE PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY. 8. THE CONTRACTOR SHALL AVOID 1N CHANNEL WORK (AT STREAM CROSSINGS) DURING THE FISH SPAWNING SEASON (APRIL 1 THROUGH JUNE 30) WITHOUT PRIOR WRITTEN APPROVAL OF THE INDIANA DEPARTMENT OF NATURAL RESOURCES-DIVISION OF FISH AND WILDLIFE. 9. IF ANY ARCHAEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY AT 1-317-232-1646. NO ADDITIONAL EXCAVATION WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 10. 11. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURES (SURFACE WETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U.S. FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES. 12. ALL SINKHOLES THAT OCCUR IN CONSTRUCTION AREAS SHALL BE LEFT UNDISTURBED ALONG WITH A 25 FOOT BUFFER AROUND THE HIGHEST CLOSED CONTOURS OF THE SINKHOLE. EXISTING VOLUME OF SURFACE DRAINAGE TO SINKHOLES SHALL BE MAINTAINED AND DRAINAGE FROM CONSTRUCTION SITES WILL BE FILTERED OR TREATED PRIOR TO ENTERING A SINKHOLE. SHEET SCHEDULE SHEET DESCRIPTION 1 COVER SHEET 2 GENERAL NOTES AND INFORMATION 3 OVERALL MAP 4 ENVIRONMENTAL INFORMATION 5-9 PLAN SHEETS 10 CROSS SECTIONS 11 • 12 TYPICAL DETAILS GENERAL NOTES AND INFORMATION REVISIONS C 2023 Midwes1ern Engineel"li. Inc. 802 West Broadway Sm,et P.O. Box 295 Loogootcc. lndiunn 47553 DATE JULY 2023 DESIGN J.W.W. DRAWN K.J.G. !. N.R.M. Q.C. CHECK PROJECT NUMBER 2021089-01 2 2 OF 12 I Fll.£ NUMBER I 43491 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2