Midwestern Engineers, Inc. Plan Preview

,, >r: , C' •� -· ,, ::, !i INDIANA DEPARTMENT OF TRANSPORTATION: Vincennes District 3550 U.S. H!GHWAY 41 VINCENNES, IN 47519 PHONE: 1-800-279-5758 EMAIL: SWl'lCOMMUNICATIONS@iNDOT.IN.GOV DISTR!CT PERMITS MANAGER RANDY CARIE PHONE. 1-812-895-7368 EMAIL RCAR !E@INDOT.IN.GOV DISTRICT PERMIT INSPECTOR CWAYNE DETZER PHONE: 812-937-4481 EMAil. DWCETZER@INDOTIN.GOV DUBOIS COUNTY: County Commissioners Chad Blessinger - District 1 Elmer Brames - District 2 Nick Hostetter - District 3 One Courthouse Square Jasper, tN 47546 Phone: {812) 481-7045 Highway Superintendent Steve Berg Dubois Co. Hwy. Dept. 1066 S. St. Rd. 162 Jasper, IN 47546 Phone: (812) 482-5505 Fax: (812) 482-5511 slberg@dubofscountyin.org Auditor Sandy Morton One Courthouse Square Jasper, IN 47546 Phone: (812) 481-7045 SHEET SCHEDULE: 1 TITLE SHEET 2 PROJECT LOCATION MAP. SHEET SCHEDULE AND GENERAL NOTES 3 GRAVITY SEWER RELOCATION PLAN AND PROFILE 4 TYPICAL DETAILS GENERAL NOTES: 1. TOPOGRAPHY St-;OWN ON PlAN SHEETS IS INTENDED TO SHOW THE GENERAL LOCATION OF FENCES, CULVERTS, DRIVES, EXISTING UTILITIES, POINTS OF CONNECTION, ETC. HOWEVER; THE EXACT LOCATION AND QUANTITIES SHALL BE VERIFIED AT THE TIME OF CONSTRUCTION. 2. THE HORIZONTAL LCCATION DATA IS BASED UPON THE INDIANA STATE COORDINATE SYSTEM (WEST ZONE) REl'ERENCED TO THE 1983 NORTH AMERICAN DATUM (NAD83). ELEVATIONS ARE BASED UPON THE 1988 NORTH AMERICA�; DATUM (NAD88). 3. THE CONTRACTOR SHALL CALL INDIANA UNDERGROUND SERVICES AT 1-800-382-5544 PRIOR TO ANY CONSTRUCTION TWO FULL WORKING DAYS BEFORE CONSTRUCTION IS TO BEGIN. 4. THE LOCATION OF EXISTING UTILITIES ETC. SHOWN ON THESE PLANS ARE NOT THE EXACT LOCATIONS BUT ONLY A GEMERAL LOCATION. AlTHOUGH THESE PLANS HAVE ATTEMPTED TO SHOW ALL EXISTING UTILITIES, THE CONTRACTOR SHALL NOT ASSUME ALL EXISTING UTILITIES HAVE BEEN SHOWN. THEREFORE IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SEE THAT ALL EXISTING UTILITIES WITHIN CONSTRUCTION AREAS ARE CLEARLY MARKED IN THE FIELD PRIOR TO ANY CONSTRUCTION IN THE AREA 5. EXAC, LOCATION OF MANHOLES, LATERALS, CLEANOUTS, ETC. TO BE DETERMINED AT THE TIME OF CONSTRUCTtON. 6. DOWN TIME COORDINATION MUST BE MADE WITH THE SEWER UTILITY PRIOR TO CONNECTION WITH EXISTING MANHOLES. COORDINATE WITH THE SUPERINTENDENT, JOEY SCHWARTZ AT (812) 267-8449 A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO TAPPING OF EXISTING MAINS. 7. PROPERTI LINES, \IVHERE SHOWN, ARE BASED UPON COUNTY PLAT RECORDS. THE SAID PROPERTY LINES ON THESE PLAN SHEETS DO NOT REPRESENT PROPERTY SURVEYS, BUT ARE ONLY APPROXIMATE LOCATIONS FOR REFERENCE PURPOSES ONLY 8. THE CONTRACTOR S>-JALL AVOID IN CHANNEL WORK (AT STREAM CROSSINGS) DURING THE FISH SPAWNING SEASON (APRIL 1 THROUGH JUNE 30) WITHOUT PRIOR WRITTEN APPROVAL OF THE INDIANA DEPARTMENT OF NATURAL RESOURCES-DIVISION OF FISH AND WILDLIFE. 9. IF ANY ARCHEOLOGICAL ARTIFACTS OR HUMAN REMAINS ARE UNCOVERED DURING CONSTRUCTION, THE CONTRACTOR SHALL STOP ALL EXCAVATION WORK AND CONTACT THE INDIANA DEPARTMENT OF NATURAL RESOURCES, DIVISION OF HISTORIC PRESERVATION AND ARCHEOLOGY, PHONE No. 317-232-1646. NO ADDITIONAL EXCAVATON WORK SHALL BE DONE WITHOUT RECEIVING THEIR APPROVAL. 10. BITUMINOUS RESURFACING WILL BE PAID BY THE LINEAR FOOT UNIT PRICE SUBMITTED WHEN CENTERLINE OF PIPE iS INSTALLED WITHINTWO (2) FEET OF THE EDGE OF A PAVED COUNTY ROAD AND RESURFAC;1jG IS COMPLETED. BITUMINOUS RESURFACING Will NOT BE A PAY ITEM BY LINEAR FEET WHENEVER CENTERLINE OF THE PIPE IS INSTALLED MORE THE TWO (2) FEET FROM THE EDGE OF A PAVED COUNTY ROAC. HO\1\/E\/ER, CONTRACTOR(S) WILL BE RESPONSIBLE TO REPLACE ANY ASPHALT DAMAGED IN THOSE AREAS. 11. STONE RESURFACING Will BE PAID AT THE UNIT PRICE PER TON SUBMITTED WHEN THE GRAVITY SEWER MAl�J OR FORCE MAIN IS INSTALLED UNDER A STONE DRIVE OR ROAD. STONE RESURFACING WILL NOT BE A PAY ITEM WHEN THE WATER MAIN IS NOT INSTALLED UNDER A STONE DRIVE OR ROAD. HOWEVER, THE CONTRACTOR(S) \/\/ILL BE RESPONSIBLE TO REPLACE ANY STONE TO BRING THE DRIVE OR ROAD BACK TO ORIGINAL CONDITION. 12. THE CONTRACTOR SHALL BE REQUIRED TO IMPLEMENT DUST CONTROL MEASURE (SURFACE \1\/ETTING) AS NECESSARY TO MINIMIZE FUGITIVE DUST EMISSIONS. 13. IF CAVERNS OR SPRINGS ARE ENCOUNTERED DURING EXCAVATION, WORK SHALL STOP IMMEDIATELY AND THE INDIANA DEPARTMENT OF NATURAL RESOURCES OR THE U.S. FISH & WILDLIFE OFFICE SHALL BE CONTACTED CONCERNING PROPER MITIGATION MEASURES. 14. ALL SINKHOLES THAT OCCUR IN CONSTRUCTION AREAS SHALL BE LEFT UNDISTURBED ALONG WITH A 25 FOOT BUFF:CR AROUND THE HIGHEST CLOSED CONTOURS OF THE SINKHOLE. EXISTING VOLUME OF SURFACE DRAINAGE TO SINKHOLES SHALL BE MAINTAINED AND DRAINAGE FROM CONSTRUCTION SITES WILL BE FILTERED OR TREATED PRIOR TO ENTERING A SINKHOLi:. 15. NOTES ON PLANS PERTAINING TO BITUMINOUS RESURFACING, NEW STORM SEWERS OR STRUCTURES, GUTTERS, SOD, SAW CUTS, DROP INLETS, CONCRETE PAVEMENT, CATCH BASINS, CULVERT PIPES, END SECTIONS, EROSIQ;� CONTROL, DITCHES, SIDEWALKS, CONSTRUCTION LIMITS, ETC,ARE FOR INFORMATION PURPOSES ONLY AND ARE NOT PART OF THE WATER MAIN RELOCATIONS. UTILITIES ELECTRIC: Dubois Rural Electric, Inc. 1400 Energy Drive Jasper, IN 47546 Phone: 812-482-5454 Orange County R.E.M.C. P.O. Box208 Orleans, Indiana 47452 Phone: Ai.in: i\r1ike Roberts mroberts@myremc.coop Southern Indiana Power 1776 10th Street Tell Ciiy, Indiana 47586 Phone: 812-547-2316 Alln: Todd Hammond thammcnd@sinpwr>oom TELEPHONE: Frontier Piiore: 800-821-8106 frontier.com Perry-Spencer Rural Telephone Cooperative 11877 E, Slate Road 62, P.O. Box126 Saint Meinrad, Indiana 47577 Phone: 812-357-2123 Attn: Jim Ferguson jfergu1son@psd>net SANITARY: Town ofBiroseye 88 W. 3rd Street Birdseys, IN 47513 Phone: 812-389-2419 VVATER: Town of Birdseye COMMUNICATIONS 88 W 3rd Streel Birdseye, IN 47513 Phone: 812-389-2419 FIBER OPTIC: Zayo Bandwidth 722 N High Schoo, Road Indianapolis, !N 46214 Phone: 765-341-1199 Atln: Waylon Higgins way !on.higgins@zayo.com GAS: Indiana Natural Gas Corp. (Paoli) P 0. Box450 Paoli, Indiana 47454 Phone: 812-723-2151 Attn: Phillip Ross phi !_r@indiananatural.com • . Know whar, below. Call before you dig, LEGEND: ----SA N---- ◊ A ◊� C ◊ 0 V V V 0 ------ PL ----SAN ____ EXISTING SANITARY SEWER EXISTING SANITARY SEWER ABANDONED EXISTING \/\/ATER LINE RIGHT-OF-WAY PROPERTY LINES EXISTING TREE LINE PROPOSED SANITARY SEWER • ® --:3 E­ ;zf EXISTING MANHOLES PROPOSED MANHOLES PROPOSED CUT/CAP EXISTING POWER POLES PROJECT LOCATION MAP I REVISIONS BIDS -- �1 @ :!022 '.'-..ildiw>c�lem ErtQ.i!l<"i'."r>', ic,c. 802 W-.c;;;\ Brood\>.iy Sir,'1.'l r.o, Box :!ll5 Loogwl.<'..:. Indw.n.J 475'.B DATE NOVEMBER 2022 DESl�N J,W W,/F.K,P. ilRIIWN K,J,G,LM,K,W, Q.C. CHECK PROJECT NUMBrn 2021092-01 2 2 Cc 4 I'll!: llUMBER 43199 I I I I ! I Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2