PROPOSED UNOERGROUND 120/240V-1•, 3W POLE MOUNTED TRANSFORMER BY DUKE ENERGY. CONTACT ADAM THORNE AT 812-318-3248 MIN. 3 WEEKS PRIOR TO COORDINATE INSTALLATION. ELECTRICAL SERVICE ------::1,.----CONTRACTOR TO PROVIDE AND INSTALL 2" SCH. CONTRACTOR TO PROVIDE----r-;I--:;:::, 40 PVC CONOUIT MIN. 30" COVER w/ PULL ROPE AND LONG SWEEP ELBOWS. CONDUCTORS FROM POLE TO METER, TERMINATIONS AND METERING BY DUKE ENERGY. & INSTALL 200A METER BASE, UNDERGROUND RINGLESS TYPE MEG APPROVED. METERING BY DUKE ENERGY. PROPOSED SQ.D NQ PANELBOARD "A" 120/240V-1., 3W 200A MCB SERVICE ENTRANCE RATED, w INTEGRAL SPD 240KA PER PHASE), TYPE 1 ENCLOSURE IN PROPOSED RESTROOM BUILDING 2DDA-2P < 2 3 4 6 5 7 9 B 10 12 11 13 14 16 15 17 18 20 19 21 22 23 24 25 26 27 28 .,___,,_. r-.. _.....,___�--------1----...-----+---�------1,----+----+-----+------.----1----..------+--------,----..-----.------. PANEL A 200AMPERES 120/240 VOLTS _<, WIRE MCB MAIN CONNECTION 1 PHASE lQ�A KAIC S\JRFACEMOUNTING S.E.L. flESrnooM LOCATION (3) #3/0 THWN 2" SCH. 80 PVC )-2DA-1P )-20A-1P )-20A-1P )-20A-2P )-20A-1P )-20A-2P )-20A-1P )-20A-2P )-20A-2P )-20A-2P )-20A-2P )-2DA-2P )-20A-2P )-20A-1P )-20A-1P )-2DA-2P )-20A-2P )-20A-1P )-20A-1P )-2DA-1P CIRCUIT ITEM FEED WIRE NO. SIZE AMPS POLE CU. POLE AMPS WIRE ITEM FEED CIRCUIT BUS SIZE NO. #4 CU. GNO. EXDTHERMICALLY WELDED TO ¾�¢x10' CU. GLAD GND. ROD (TYP. OF 3 ON 10' TRIANGULAR SPACING) 0 0 0 G) 0 0 0 0 0 0 0 0 POLES 1,2 0 POLES 3,4 0 POLE 5,6 0 POLES 7,8 0 POLES 9,10 0 0 POLES 11,12 0 0 0 0 0 0 SITE LIGHTING TIMER RESTROOM LIGHTS 12ov-1• HAND DRYER #1 12ov-1• LEGEND WALL HEATER #1 24OV-1¢ (2) #12 THWN, (1) #12 CU. GND., 1" CONDUIT (2) #10 THWN, (1) #10 CU. GND., 1" CONDUIT CONTRACTOR TO PROVIDE AND INSTALL 3DA SQ.D CLASS 8903LXG ELECTRICALLY HELD 12 POLE LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE AND HAND-OFF-AUTO SELECTOR SWITCH. WIRE TO NEW TIMER FOR AUTO OPERATION. HAND DRYER #2 12ov-1• CONTRACTOR TO TYPICALLY USE THE SAME CONDUIT AND WIRE THROUGHOUT THE BRIDGE LIGHTING CONNECTIONS AS NOTED. WALL HEATER #2 240V-1¢ RESTROOM RECEPTACLES 12OV-10 "E22" 0 0 "E23" 0 0 "E24" 0 0 "E25" 0 0 "E26" 0 0 " E27" 0 0 "E28" 0 "E9" "E1a" "E11" "E12" "E13" � E14" "E15" "C2" 0 "D1" 0 "02" 0 "03" 0 "D4" 0 0 RESTROOM EXTERIOR AND TRAIL "A" LIGHTS 240V-1¢ "E16" SHELTER 0 "E17" 0 "E18" 0 "E19" 0 "E20" PARKING LOT AND ENTRANCE LIGHTS 240V-1¢ HOUSE LIGHTS 24OV-10 0 "EJ" 0 "E4" 0 "ES" 0 0 PLAYGROUND LIGHTS 24DV-1o PROPOSED POWER DISTRIBUTION ONE LINE DIAGRAM NOT TO SCALE LIGHT FIXTURE SCHEDULE Type Manufacturer / Model Mounting Lamps A NEWSTAR LIGHTING - CATALOG No. VIC4N-L1-35-1C-RWC-UN-WH SURFACE 25W LED B NEWSTAR LIGHTING - CATALOG No. VIC4N-L2-35-1C-RWC-UN-WH SURFACE 50W LED C BEACON LIGHTING - CATALOG No. RWL1-48L-10-4K7-3-UNV SURFACE 7.8W LED D PRESCOLITE LIGHTING - CATALOG No. LTR-6RD-H-SL1OL-DM01 SURFACE 10.1W LED LTR-6RD-T-SL4DK8XW-SS LTR-6RD-CE-"B6 E LIGHTING - CATALOG No. CAPITOL SERIES 14'-BLK RTF 71 LED 45W TYPE Ill POLE 7.8W LED F LIGMAN LIGHTING - CATALOG No. UAB-30031-7WLED-W4D-12D/277V-SCBT BRIDGE 7.8W LED NOTE: CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS, BRACKETS, CABLES, PHOTOCELLS, ETC. FOR FULLY FUNCTIONAL SYSTEM. NOTE: CONTRACTOR TO CONTACT TRAVIS BELDEN WITH ESL SPECTRUM AT (317) 800-8552 FOR LIGHT FIXTURE PRICING PRIOR TO BID. NOTE: POLE FOR CAMERA SYSTEM AT PARKING LOT SHALL BE HAPCO SSS14B4-4-DOOO-C10-VD2-BA w/ 1" THREADED COUPLINGS AT 12'. BOLT PATTERN PER MANUFACTURER, USE SAME BASE DETAIL AS "E" FIXTURES. "F2" 0 "F3" 0 "F4" 0 "F5" 0 "F6" 0 0 0 "F9" 0 "F1O" 0 "F11" 0 "F12" SOUTH BRIDGE LIGHTS 240V-1• 0 0 0 0 0 0 0 0 0 0 "F14" "F15" SHLETERHOUSE RECEPTACLES 12OV-10 "F16" "F17" "F18" "F2O" "F21" "F22" "F23" G) 0 !"F36" NORTH BRIDGE LIGHTS 24OV-10 0 CAMERA EQUIPMENT RECEPTACLE 120V-1¢ 0 0 WATER HEATER 120V-1¢ RESTROOM RECEPTACLES 12OV-10 0 RESTROOM EXH. FANS 12ov-1• 0 PLUMBING TRANSFORMER 12ov-1• UNISEX R.R.#1 �s==:::::::_-- HAND DRYER WALL HEATER 0 WALL HEATER HAND DRYER A-3 A-4,6 A-5 UNISEX R.R.#2 A -, 7,9 0 GFI A UH-2 120V-10 "A 1 SITE LIGHTING TlMER 3 HAND DRYER #1 5 HAND DRYER IJ2 7 WALL HEATER #2 9 PARKING LOT AND ENTRANCE LIGHTS 13 � PLAYGROUND LIGHTS 17 NORTH BRIDGE LIGHTS 21 23 CAMERA EQUIPMENT DUPLEX RECEPT. 25 RESTROOM RECEPTACLES 27 PLUMBING TRANSFORMER 29 31 33 35 37 39 41 ' ' SPARE SPARE SPARE SPARE SPACE SPACE SPACE ' OCCUPANc/', .., SENSOR "-...... .... ---- GFl A-25 UH-2 RESERVE WALL AND FLOOR SPACE FOR FUTURE SECURITY SYSTEM EQUIPMENT. ALL SITE SECURITY CONDUITS SHALL STUB UP AND BE CAPPED IN THIS AREA w/ PULL ROPE FOR FUTURE USE. I / PROPOSED LIGHTING CONTACTOR AND TIMER 12 20 1 12 20 1 12 20 1 12 20 2 12 20 2 12 20 2 12 20 2 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 12 20 1 EF-1 A-28 A-27 A 1 20 8 2 20 A B 1 20 A 2 20 B A 2 20 8 A 2 20 8 A 1 20 B 1 20 A 1 20 B 1 20 A 1 20 8 1 20 A 1 20 B 1 20 A 8 A 12 RESTROOM INT. LIGHTS 12 WALL HEATER #1 12 RESTROOM RECEPTACLES 12 TRAJL 'A' LIGHTS 12 RESTROOM EXTERIOR AND SHELTER HOUSE LIGHTS 12 SOUTH BRIDGE LIGHTS 12 SHELTERHOUSE RECEPTACLES 12 WATER HEATER 12 RESTROOM EXHAUST FANS 12 ELECTRIC ROOM BASEBOARD HEAT 12 SPARE 12 SPARE 12 SPARE 12 SPARE SPACE SPACE SPACE LOW VOLTAGE CONTROL WIRE IN CONDUIT TO EACH FIXTURE THEN HOME RUN TO STEP DOWN TRANSFORMER. SEE PLUMBING SHEET FOR f----�A=D=Dl� Tl� ONAL INFORMATION 1:;:±;=!-------- STEP DOWN TRANSFORMER FOR FLUSH VALVE POWER/CONTROL SERVICE ENTRANCE� I FROM DUKE ENERG f , 7 SEE SITE PLAN FOR " CONTINUATION I PROPOSED 2DDA METER BASE J ___ _j_'._ _____ _lI,!i_ ___ _t=t=:i_ _ _ _ _l]$ -,:= =!=1="\'=Ji=/ "=' E t--,--,--e--•==� � ' - -- --, , , , -, l(3) 1" SCH. 80 PVC j OCCUPANCY SENSOR "A" EF-1 A-26 SPARES CAPPED ON EACH END FOR FUTURE USE PULL BOX w/ SERVICE ENTRANCE AND SPARE LOW VOLTAGE CONTROL WIRE IN CONDUIT TO EACH FIXTURE THEN HOME RUN TO STEP DOWN TRANSFORMER. SEE PLUMBING SHEET FDR ADDITIONAL INFORMATION PROPOSED ELECTRICAL PLAN SCALE: )," � 1'-D" 2 ,_j._. 6 8 10 12 �16 18 20 22 24 26 28 30 32 34 36 38 40 42 REVISIONS 10/25/23 BID SET C 2023 Midwcs1cm Engineer�. lnc. 802 Wes! Broadwny Stret,t P.O. Box 295 Loogootee. Indiana 47553 DATE OCTOBER 2023 DESIGN AFB DRAWN CNM a.c. CHECK CWR PROJECT NUMBER 2022024-05 38 38 OF 48 I FIL£ NUMBER I 53551 Do Not Use Plan Previews for Take Off

RkJQdWJsaXNoZXIy NjAyODM2